Due to strict commerce control regulations, AAATesters does not ship or export Thermal Imagers to any countries outside of the United States. |
International customers, please note that we cannot complete any order that includes a Thermal Imager product. AAATesters cannot complete any sale where the intent may be that a Thermal Imager product may be exported internationally by the end user. |
All customers that are purchasing Thermal Imager products from AAATesters will be required to complete a BIS-711 end use agreement form to ensure that the Thermal Imager product will not be exported internationally. |
The ultimate tools for troubleshooting and maintenance This thermal Imager is the perfect tool to add to your problem solving arsenal. Built for tough work environments, this high-performance, fully radiometric infrared camera is ideal for troubleshooting electrical installations, electro-mechanical equipment, process equipment, HVAC/R equipment and others.
IR-Fusion® Technology See things both waysラinfrared and visual (visible light) images fused together communicating critical information faster and easierラtraditional infrared images are no longer enough. IR-Fusion, a patent-pending technology that simultaneously captures a digital photo in addition to the infrared image and fuses it together taking the mystery out of IR image analysis. IR-Fusion is standard on Fluke Ti25.
Features:
- Enhanced problem detection and analysis capabilities with IR-Fusion® Technology. Simply scroll through the different viewing modes quickly to better identify trouble areas in Full IR thermal, picture-in-picture, or automatic blend visual and thermal images.
- Optimized for field use in harsh work environments.
- Engineered and tested to withstand a 2 m (6.5 ft) dropラWhen was the last time you dropped a tool?
- Withstands dust and waterラtested to an IP54 rating.
- Delivers the clear, crisp images needed to find problems fast.
- Identify even small temperature differences that could indicate problems with excellent thermal sensitivity (NETD).
- Intuitive, three-button menu is easy to useラsimply navigate with the push of a thumb.
- Reflected background temperature (reflected temperature compensation)
- No need to carry pen and paperラrecord findings by speaking into the camera. Voice annotations can be recorded with every image you take. Voice comments are saved along with individual images for future reference.
- Everything needed to get started is included. Training DVD is now included free. See how easy it is to set up your thermal imager, create professional reports with SmartView software and learn thermography theory with step-by-step video instructions.
- Adjustable hand strap for left-or right-handed use.
Specifications
Detailed specifications |
Temperature |
Temperature measurement range (not calibrated below -10 °C) |
-20 °C to +350 °C (-4 °F to + 662 °F) (two ranges) |
Accuracy |
± 2 °C or 2 % (whichever is greater) |
On-screen emissivity correction |
Yes |
|
Imaging performance |
Field of view |
23° x 17° |
Spatial resolution (IFOV) |
2.5 mRad |
Minimum focus distance |
Thermal lens: 15 cm (6 in) Visible (visual) light lens: 46 cm (18 in) |
Focus |
Manual |
Image frequency |
9 Hz refresh rate |
Detector type |
160 X 120 focal plane array, uncooled microbolometer |
Infrared lens type |
20 mm F = 0.8 lens |
Thermal sensitivity (NETD) |
= 0.1 °C at 30 °C (100 mK) |
Infrared spectral band |
7.5 µm to 14 µm |
Visual camera |
640 x 480 resolution |
|
Image presentation |
Palettes |
Ironbow, blue-red, high contrast, amber, hot metal, grey |
Level and span |
Smooth auto-scaling and manual scaling of level and span |
Minimum span (in manual mode) |
2.5 °C (4.5 °F) |
Minimum span (in auto mode) Fast Auto/Manual Range Toggle Fast Auto Rescale |
5 °C (9 °F) |
IR-Fusion® information |
Full infrared with MAX, MID, or MIN automatic blending; and picture-in-picture with MAX, MID, or MIN automatic blending (Visual and IR blending) |
Picture-In-Picture (PIP) |
Three levels of on-screen IR blending displayed in center 320 x 240 pixels |
Full screen (PIP off) |
Three levels of on-screen IR blending displayed in center 640 x 480 LCD |
|
Voice annotation |
Voice annotation |
60 seconds maximum recording time per image |
|
Image and data storage |
Storage medium |
SD memory card (2 GB memory card will store at least 1200 fully radiometric (.is2) IR and linked visual images each with 60 seconds voice annotations or 3000 basic (.bmp) IR images) |
File formats |
Non-radiometric (.bmp) or fully-radiometric (.is2) No analysis software required for non-radiometric (.bmp) files |
Export file formats w/SmartViewル software |
JPEG, BMP, GIF, PNG, TIFF, WMF, EXIF, and EMF |
|
General specifications |
Temperature |
Operating: |
-10 °C to 50 °C (14 °F to 122 °F) |
Storage: |
-20 °C to +50 °C (-4 °F to 122 °F) without batteries |
|
Relative humidity |
|
10 % to 90 % non-condensing |
|
Display |
|
9.1 cm (3.6 in) diagonal landscape color VGA (640 x 480) LCD with backlight (selectable bright or auto) |
|
Controls and adjustments |
|
User selectable temperature scale (°C/°F) |
|
Language selection |
|
Time/Date set |
|
Software |
|
SmartViewル full analysis and reporting software included |
|
Power |
Battery: |
Internal rechargeable battery pack (included) |
Battery life: |
Three to four hours continuous use (assumes 50 % brightness of LCD) |
Battery charge time using ac adapter/charger and dc car charger: |
Two hours for full charge |
|
AC operation/charging |
|
AC adapter/charger (110 Vac to 220 Vac, 50 Hz to 60 Hz). Charges battery while imager is operating. Universal ac mains adapters included. |
|
Power saving |
|
Sleep mode activated after 5 minutes of inactivity, automatic power off after 20 minutes of inactivity |
|
Safety standards |
CE Directive: |
IEC/EN 61010-1 2nd Edition Pollution Degree 2 |
|
Electromagnetic compatibility |
EMC directive: |
EN61326-1 |
C-Tick: |
IEC/EN 61326 |
US FCC: |
CFR 47, Part 15 Class A |
|
Vibration |
|
Shock |
|
25 G, IEC 68-2-29 {2 m (6.5 ft) drop, 5 sides} |
|
Dimensions (HxWxL) |
|
0.27 m x 0.13 m x 0.15 m (10.5 in x 5 in x 6 in) |
|
Weight |
|
IP rating |
|
Calibration cycle |
|
Two-years (assumes normal operation and normal aging) |
|
Supported languages |
|
English, Italian, German, Spanish, French, Russian, Portuguese, Swedish, Turkish, Czech, Polish, Finnish, Simplified Chinese, Traditional Chinese, Korean, and Japanese |
|
For full Fluke Ti25 specifications, please click here:
Fluke Ti25
There Are Shipping Restrictions On This Item. Please See Description.
2 Fluke Ti25 Infrared Thermal Imagers
20mm Lens, 9Hz With a Focal Plane Array Of 160x120
Temperature Range -20°C to +350°C (-4°F to + 662°F)
Includes Carrying Cases & Accessories As Listed!
Fluke Set of 2 Ti25 Ti 25 Thermal Imager Models On Sale Warranty Calibration Backed by The Best Service and Lowest Prices in the Industry.