The Dynatelル 965DSP Subscriber Loop Analyzer executes a wide range of individual tests and performs automatic test routines to categorize and sectionalize problems.The hand-held 965DSP test set is housed in a lightweight, ergonomically designed case for portability and ease of handling. The unit is weather-resistant and weighs only 3.3 pounds (1.5 kg).

Name

Value

Auto test POTS, POTS & Broadband
Basic VOM Yes
China RoHS - Below MCV Undetermined
EU RoHS Compliant Non-applicable
Gross Weight 7 Pound
Net Weight 3.3 Pound
Operating Altitude 0 to 16600 Linear Foot
Operating Temperature Range -18 to 60 Degree Celsius
Relative Humidity 0 to 95 Percent
Size (H) 10.0 in. x (W) 4.0 in. x (D) 2.5 in.
Storage Temperature -40 to 75 Degree Celsius
Usage POTS, POTS & Broadband, Fault Locating, Noise Mitigation
Weather resistant Yes

The 3M Dynatel 965DSPSubscriber Loop Analyzer is a microprocessor-controlled integrated test set that provide full-featured POTS and fundamental ISDN testing. The functions include fault location and repair verification on twisted-pair, quad and coaxial cable (utilizing capacitance bridge &resistance bridge functions).

The Dynatel 965DSPsubscriber loop analyzer executes a wide range of individual tests, or performs automatic test routines as specified by the user to categorize and sectionalize problems. Specific tests and measurements performed by the unit include:

  • Voltage ヨ detects and measures the presence of exchang or foreign DC or AC voltages.
  • Tone ヨ provides a test tone for conductor identification; user-selected tones from 1 to 40 kHz for transmission measurements.
  • Current ヨ measures DC loop current.
  • Ohms ヨ measures conductor and insulation resistance u to 1000 megohms.
  • Resistance fault location ヨ displays distance to fault.
  • Opens ヨ locates opens at distances up to 100,000 ft. (30 km).
  • Splits ヨ locates splits on paired cable.
  • Ringer count ヨ counts the number of ringers on a particular loop.
  • Load coil count ヨ indicates the presence of load coils in loop circuit.
  • Wideband loss ヨ loss measurements to 200 kHz for pre-qualifying ISDN and HDSL.
  • Loss ヨ measures voice band loss.
  • Noise ヨ measures noise metallic and noise to ground in dBrnc.
  • Longitudinal balance ヨ provides active measurement of line balance.

Electrical Specifications

Main Functions Range Resolution Accuracy
Voltage (DC) 0 to 99.9 V 100 to 300 V 0.1 V 1 V 1% ± 0.5 V 3%
Voltage (AC) 0 to 99.9 V 100 to 250 V 0.1 V 1 V 1% ± 0.5 V 3%
Current 0 to 59.9 mA 60 to 110 mA 0.1 mA 0.1 mA 1% ± 0.3 mA 2%
Resistance (DC) with CO voltage 0 to 9999 O
0 to 9999 O
10 k to 99.9 kO
100 k to 999 kO
1 M to 9.9 MO
10 M to 99 MO
100 M to 990 MO
1 O
1 O
0.1 kO
1 kO
0.1 MO
1 MO
10 MO
1% ± 5 O
1% ± 50 O
1%
3%
3%
5%
10%
Opens (no noise) 0 to 3,000 ft (0 to 1000 m)
3,000 to 10,000 ft (1 km to 3 km)
10,000 to 50,000 ft (3 km to 15 km)
50,000 to 100,000 ft (15 km to 30 km)
1 ft (1 m)
1 ft (1 m)
10 ft (10 m)
100 ft (100 m)
1% ± 3 ft
3%
5%
10%
RFL
Fault range Resistance to fault (no noise)
0 to 20 MO
0 to 99.99 O
100 to 999.9 O
1 kO to 7 kO

0.01 O
0.1 O)
1.0 O

0.1% of RTS ± 0.01 O
0.2% of RTS ± 0.01 O
1.0% of RTS ± 0.01 O
Loss (& frequency) -40 to +10 dBm, 200 to 3000 Hz
-40 to +10 dBm, 3000 to 9995 Hz
-40 to +10 dBm, 10 k to 19.9 kHz
0.1 dB, 1 Hz
0.1 dB, 5 Hz
1 dB, 10 Hz
0.5 dB, 2 Hz
0.5 dB, 10 Hz
1 dB, 20 Hz
Wideband loss -40 to +10 dBm, 20 k to 200 kHz 1 dB, 100 Hz 2 dB, 0.1 kHz
Noise metallic 0 to 50 dBrnc (-90 to -40 dBm0p) 1 dB 2 dB
Noise to ground 40 to 100 dBrnc (-50 to 10 dBm0p) 1 dB 2 dB
Longitudinal balance 62 to 40 dB 1 dB 2 dB
Tone output
ID
User defined
User defined
ISDN
200 to 1000 Hz, fixed level
200 to 9995 Hz, -20 to +1 dBm
10 k to 19.99 kHz, -20 to +1 dBm
40 kHz, +6 dBm fixed level
1 Hz
1 Hz, 0.1 dB
10 Hz, 1 dB
1%
1% Hz, 0.2 dB
2% Hz, 1 dB
2%, 2 dB
Dial mode DTMF, Pulse Standard Standard
ISDN Link test Error test Active/inactive Near-end & far-end block errors ラ 1 error ラ 1 error
Auto Same specifications as full tests See above See above



For full 3M Dynatel 965DSP-BSI product specifications, please click here: 3M Dynatel 965DSP-BSI

3M Dynatel 965DSP-BSI Subscriber Loop Analyzer Version 7.00.9

Installed Options:
ISDN/ISDL
HDSL
ADSL
TDR

Usage:  POTS, POTS & Broadband, Fault Locating, Noise Mitigation

Includes Carrying Case & Accessories As Listed!

965DSP 965 DSP DSPB DSP-B BSI

3M Dynatel 965DSP-BSI 965-DSP-BSI Subscriber Loop Analyzer Models On Sale Warranty Calibration Backed by The Best Service and Lowest Prices in the Industry.

BC# 12549

  • 3M Dynatel 965DSP-BSI Subscriber Loop Analyzer V7.00.9 (BC# 12549) w/ Option:
    • ISDN/ISDL
    • HDSL
    • ADSL
    • TDR 
  • Test Lead Set
  • AC Adapter/Charger
  • Power Cord
  • User Manual On CD-ROM
  • Carrying Case (G)