EXFO VCS-20A kit with accessories

EXFO VCS-20A-02B Multifunction SM Fiber Optic Talk Set 1310nm VCS-20A VCS20A

Sunrise Telecom Sunset 10G kit with accessories

Sunrise Telecom Sunset 10G SDH Network Tester

AFL Noyes M210 Quad SM MM Fiber OTDR w/ PM VFL

$4,695.00
Availability: In stock
SKU
3P07

Condition: Refurbished / Calibrated

Warranty: 1 YEAR WARRANTY

 

M210 Hand-held OTDR with OPM, VFL, & Touch and Test® Intuitive User Interface

NOYES M210 OTDR from AFL combines ease of use (Touch and Test®) and multi-functionality in a field rugged, hand-held package. Integrated OTDR and OPM functionality and inspection capability reduce setup and testing time and simplify documentation; reducing testing and administration costs.

With single-mode dynamic ranges of up to 30 dB and multimode dynamic ranges of 26 dB, the M210 is ideal for testing, troubleshooting and documenting enterprise, LAN/WAN, campus and military single-mode and multimode (62.5 and 50 micron) fiber networks.

The latest member of the NOYES M200 product family combines market proven reliability with expanded capabilities. Launched in 2006, the M200 is a 2012 Test of Time finalist, and used by thousands of AFL customers.

M210 Multifunction OTDR Features:

  • Built in Optical Power Meter - Easily test and store both Tier 1 and Tier 2 results in one tester
  • Built in Visual Fault Locator (VFL) enables technicians to quickly identify fiber faults within OTDR dead zone
  • Dynamic Range covers longer fiber systems
    • 30 dB Single-mode
    • 26 dB Multimode
  • Field proven, compact, rugged product packaging is designed for both outside plant use and cramped inside plant environments. 

M210 Touch and Test® supports users of all levels

Full Auto Mode ヨ Connect and press test. M210 will detect fiber and set recommended test parameters. Perfect for novice technicians or repair techs quickly looking for faults on fiber spans of unknown length.

Auto-Once Mode ヨ Designed for testing cables with multiple fibers. M210 performs a full auto test on the first fiber and retains recommended settings allowing fast expert-speed testing of subsequent fibers.

Expert Mode ヨ Provides access to testing parameters for experienced users to setup optimal testing scenarios for specific networks.

Real-Time Mode ヨ Continuous OTDR operation and display update allows users to dynamically change networks while monitoring OTDR trace results. Example: relaxing fiber bends to reduce attenuation loss.

Top menu level touch screen access to major test modes allow users to test networks faster- no time wasted with complicated menu structures. The M210 provides one-touch access to OTDR and OPM test modes and DFS inspection mode when enabled.

M210 Touch and Test® Features 

  • Set Pass/Fail thresholds compliant with TIA/ISO/user-defined values to alert test operators of failing or marginal events.
  • New Job creation editor with detailed job/file naming allows users to quickly create file for storing results with flexibility for custom Job, Route, Cable, Fiber file naming.
  • Structured file management to logically and easily store test results.
  • Results Manager allows in-unit review saved test results and quick selection of previously created jobs for storing current job test results.
  • Access general settings including Date/Time/Number format options and an Auto Off feature.
  • OTDR settings enhanced event measurements with various manual LSA methods available in Expert mode.
  • A simple toggle function enables fast and logical storage of trace, Loss and inspection results from both ends of a fiber/cable.

The M210 supports visual inspection per IEC 61300-3-5 visual inspection practices using a NOYES DFS1 Digital FiberScope providing the user the ability to view and document connector end-face images with their OTDR traces and loss/power measurements

Touch and Test® capabilities simplify the user experience; reduce training time and testing errors enabling even novices to get the job done quickly and accurately.

Specifications 
 

OTDR MULTIMODE SINGLE-MODE
Emitter Type Laser Laser
Safety Class Class I FDA 21 CFR 1040.10 and 1040.11; IEC 60825-1:2007-03 Class I FDA 21 CFR 1040.10 and 1040.11; IEC 60825-1:2007-03
Center Wavelengths 850/1300 nm 1310/1550 nm
Wavelength Tolerance  ±20/±30 nm ±20/±30 nm
Dynamic Range (SNR = 1) 26 dB 30 dB
Event Dead Zone 1.5 m 1.5 m
Attenuation Dead Zone 9 m 9 m
Pulse Widths 10, 30, 100, 300 ns, 1 µs, 3 µs 10, 30, 100, 300 ns, 1, 3, 10 µs
Range Settings 250 m to 32 km 250 m to 208 km
Sampling Points Up to 16,000 Up to 16,000
Minimum Data Point Spacing 0.25 m 0.25 m
Group Index of Refraction (GIR) 1.4000 to 1.6000 1.4000 to 1.6000
Distance Uncertainty/Accuracy ±(1 + 0.005 % x distance + data point spacing) ±(1 + 0.005 % x distance + data point spacing)
Linearity ±0.05 dB/dB ±0.05 dB/dB
Loss Threshold 0.02 dB 0.02 dB
Loss Resolution 0.01 dB 0.01 dB
Reflectance Resolution 0.01 dB 0.01 dB
Reflectance Accuracy ±2 dB ±2 dB
Real Time Refresh Rate 1 Hz 1 Hz
Units m, km, ft, kft, mi
OTDR Modes  Full Auto, Expert, Real-Time
Trace File Format  Bellcore GR-196 Version 1.1
Trace File Storage  Medium Internal and USB
Trace File Storage Capacity  >1000 internal, 1000s on USB
Trace File Transfer to PC USB




For full Noyes M210 product specifications, please click here: Noyes M210

NOYES M210 QUAD Singlemode 1310 / 1550nm & Multimode 850 / 1300nm Fiber OTDR With Power Meter & VFL

Dynamic Range:
1310 / 1550 nm : 30 / 30 dB
850 / 1300 nm : 26 / 26 dB

Power Meter:
- 850nm
- 1300nm
- 1310nm
- 1490nm
- 1550nm
- 1625nm
- 1650nm

Includes Hard Carrying Case & Accessories As Listed

M210 M 210 M200 200

Noyes M210 OTDR Mainframe M 210 OTDR Models On Sale Warranty Calibration Backed by The Best Service and Lowest Prices in the Industry.

BC# 35077-L/T*

  • Noyes M210 QUAD SingleMode MultiMode OTDR (BC# 35077-L/T*)
    • SM OTDR Source:
      • 1310nm
      • 1550nm
    • SC Connectors For SM Source
    • MM OTDR Source
      • 850nm
      • 1300nm
    • SC Connectors For MM Source
    • Power Meter:
      • 850nm
      • 1300nm
      • 1310nm
      • 1490nm
      • 1550nm
      • 1625nm
      • 1650nm
    • SC Connector For Power Meter
    • 2.5mm Connector For Power Meter
    • VFL
  • TRM Test Results Manager Software Version 1.6.5
  • Noyes OTDR Quick Reference Guide
  • (2) SM SC - SC Fiber Cables
  • (2) MM SC - SC Fiber Cables
  • (4) Fiber Wipes
  • Stylus
  • AC Adapter/Charger
  • Power Cord
  • USB PC Interface Cable
  • Strap For Unit
  • Carrying Case
Request a Quote for

Have Questions or doubts? Submit the following request and expect our detailed quote within 24 hours!

we are commited to win your business!