JDSU T-BERD 6000 Compact Optical Test Platform Mainframe
Key Features:
- Compact, lightweight, and highly integrated platform
- More than 40 application modules already supported for, multimode and
single-mode
- Built-in VFL, power meter, LTS, ORL, and video inspection, scope options
- Choose from IL/ORL,OTDR,PMD,CD, AP and/or WDM, plug-ins
- Exceeds Telcordia specifications for ruggedness, drop, testing, and
extended battery life
- Compatible with plug-in modules from the MTS-51001, and T-BERD 8000
Applications
- Performs multimode and, single-mode OTDR and optical loss, test
(bidirectional)
- Conducts connector inspection and, continuity testing
- Finds faults and identifies traffic
- Tests FTTx/PON and CWDM, networks
- Performs fiber dispersion testing, (PMD/CD/AP) for 10G/10GE/40G
- Allows for use of talk set/data port, for automated end-to-end,
communication and unit control
- Generates proof-of-performance, reports
The JDSU T-BERD 6000 is a highly integrated test platform designed for all,
phases of the fiber network life cycle. It provides field service technicians
with the, highest levels of performance and upgradeability on the market
today.
The modular design of the T-BERD 6000 offers an extensive portfolio of test,
functionality with over 40 different fiber modules supporting a wide range of,
applications. The versatility of the T-BERD 6000 allows technicians to
standardize, using one type of test equipment and then introduce new testing
capabilities in, the field without incurring additional training or device
costs.
The T-BERD 6000 is compatible with our existing fiber module product line,
so, technicians can exchange plug-in modules between the T-BERD-8000 Scalable,
Optical Test Platform and the T-BERD 6000, in the field and without the need
for, additional tools. To ensure the highest level of return on your capital
investment, for test equipment, an extension allows you to upgrade existing OTDR
modules, from the MTS-5100 for use with the T-BERD 6000.
To ensure the highest-level return on investment for your test equipment,
upgrade, existing optical time domain reflectometer (OTDR) modules from the
MTS-5100, (with an extension) for use with the T-BERD 6000.
Ideal for Field Testing
The T-BERD 6000 is a highly integrated platform with a single module slot
and, the option to extend internal memory up to 1 gigabyte. The platform
features an, intuitive graphical user interface (GUI) shown on a large 8.4 inch
transreflective, color display (with an optional touchscreen) to improve viewing
under any, condition. The high capacity Lithium ion battery adds extended life.
Other, features include an optional video inspection scope (via USB port), and
optional, built-in optical test functions, such as a visual fault locator (VFL),
power meter,, optical return loss (ORL) and loss test sets (LTS). The T-BERD
6000 also has a, built-in optical talk set option for communicating and
controlling remote units, along the fiber, and it can transfer data fast using
the USB or Ethernet port.
Overview of Fiber Optic Applications
Compact and Highly Integrated The versatility of the
T-BERD 6000 allows it to address premises to long-haul, networks comprising new
technologies, such as various fiber networks (FTTx),, remote optical add/drop
multiplexers (ROADMs), and 40 G.
- Built-in VFL, laser source power meter, LTS, talk set/data, and video
inspection, scope options (simultaneously)
- Bidirectional insertion loss (IL) and ORL capabilities combined in one
module
- OTDR and chromatic dispersion (CD) capabilities combined in one module
- Polarization mode dispersion (PMD), wave division multiplexing (WDM), and,
attenuation profile (AP) capabilities combined in one module
- PMD, CD, and AP capabilities combined in one module
|
Wide Range of Test
Applications |
| LAN/WAN Premises |
– 10 GigE local area network (LAN)
qualification Solution: T-BERD 6000 with the unique universal SRL
850/1300/1310/1550/1625 nm OTDR Module |
|
|
| FTTx/Access Networks |
– End-to-end connectivity on point-to-point
networks, including sectionalized, testing on a passive optical network
(PON) (without a splitter, Solution: T-BERD 6000 with the VSRe, SRe,MR
OTDR module at 1310/1550 nm – End-to-end connectivity on PONs,
including splitter qualification Solution: T-BERD 6000 with the MR, LR,
or VLR at 1310/1490/1550 nm OTDR, module Add optional VFL, power meter,
and video inspection scope – In-service maintenance and troubleshooting
without service disruption Solution: T-BERD 6000 with the filtered LR
OTDR module at 1625 nm |
|
|
| Metro/Core Networks |
– End-to-end connectivity and fiber splice
qualification Solution: T-BERD 6000 with the MR, LR, or VLR at
1310/1550/1625 nm OTDR module Add optional VFL, power meter, and video
inspection scope |
|
|
| Ultralong-Haul Networks |
– End-to-end connectivity and fiber splice
qualification Solution: T-BERD 6000 with the UHD OTDR m |
|
|
| 10G/40G Fiber Characterization |
– Characterize fiber in high-speed transmission
systems for loss/dispersion Solution: T-BERD 6000 with the PMD/CD/AP,
ODTR, and OFI module |
|
|
| CWDM/DWDM |
– Characterize fiber and prove suitability to
carry multiple channels (water peak) Solution: T-BERD 6000 with the VLR
OTDR module at 1383 nm Add the combined PMD/WDM/SA or CDWM OTDR
module |
|
|
| Modular Platform |
– New technologies developed in the
future Solution: T-BERD 6000 with the new JDSU field-upgradeable
application module |
OTDR and IL/ORL Testing
A Wide Range of OTDR Modules The JDSU OTDR plug-in module
family provides a wide range of highperformance, OTDRs. Over 40
field-interchangeable modules are compatible with, the T-BERD 6000 for testing
and troubleshooting any multimode or single-mode, network. The OTDR family
includes six lines of OTDRs featuring:
- New wavelengths to cover 1383 nm (CWDM) and 1490 nm (FTTx)
- Highest dynamic range up to 50 dB
- Shortest dead zones down to 0.5 m in multimode and 0.8 m in singlemode
- Fastest scan speed at 0.1 s in real-time mode
From Simple Fault Locator to Expert OTDR… The fault
locator boosts productivity in the field by providing:
- Fast detection
- Precise fault location
- One-button automation
- No specific settings required
- Distance, loss, and ORL measurements
The expert mode offers high-level trace analysis possibilities, making your,
T-BERD 6000 platform a powerful instrument for commissioning and
troubleshooting, by offering:
- Manual settings (pulse, acquisition time, resolution, distance range)
- Manual addition and deletion of events
- Manual slopes, splices, and reflectances measurement
Ideal for End-to-End Commissioning OTDR bidirectional
testing is required to obtain true and accurate splice loss, readings. JDSU has
developed an innovative automatic bidirectional analysis, function that is
integrated directly into the T-BERD 6000 platform, saving at least, 50 percent
of the time required for traditional bidirectional analysis.
- Offers communication between two units via the link under test to set up
the, same optimized acquisition parameters
- Displays and saves automatic acquisitions in both directions on both units
- Eliminates operator error
CWDM OTDR Modules The CWDM OTDR module allows in-service
OTDR measurements at, International Telecommunications Union (ITU-T) G.694.2
CWDM wavelengths.
This solution was developed to help network operators and dark fiber
providers, characterize, maintain, and troubleshoot CWDM systems from short- to
mediumhaul, fiber networks.
FTTx/PON In-Service Modules To avoid interrupting
customer traffic (in-service testing) of B/G/E-PON, networks the filtered OTDR
module performs an out-of-band test using 1625 nm, wavelength.
Insertion Loss and Optical Return Loss Testing
- Measures bidirectional IL, ORL, and fiber length
- Offers one-button automated testing
- Choose three wavelengths from 1310, 1490, 1550, and 1625 nm
- Compatible with the OFI-2000 Multifunction Loss Test Set
CD,PMD,AP, and WDM Testing
The T-BERD 6000 enables CD and PMD measurements to identify fiber viability,
for very high-speed transmission systems. It also enables WDM and AP tests to,
validate the link compatibility with DWDM system implementation.
Polarization Mode Dispersion Testing
- Fast and accurately measures PMD delay, PMD coefficient, and, second-order
values
- Offers high dynamic range (up to 65 dB) dedicated for metropolitan, long
haul,, and very long haul fiber optic links
- Offers shock- and vibration-proof design (with no moving parts)
- Allows for measurement through multiple amplifiers
- Provides statistics and long-term monitoring
Chromatic Dispersion Testing - OTDR-Based Method
- Requires access to only one end of the fiber
- Offers dynamic range (up to 120 km) dedicated for any metropolitan fiber
optic, links
- Includes acquisition points around 1310, 1480, 1550, and 1625 nm for
accurate, CD from 1260 to 1650 nm
- Integrates a four-wavelength OTDR and light source
- Provides sectional analysis capability for troubleshooting
- Offers shock- and vibration-proof design (with no moving parts)
Chromatic Dispersion Testing - Phase-Shift Method
- Offers high dynamic range (up to 55 dB) dedicated for metropolitan, long
haul,, and very long haul fiber optic links
- Provides full wavelength range characterization (1260 to 1640 nm)
- Allows for measurement through multiple amplifiers
- Offers shock- and vibration-proof design (with no moving parts)
Attenuation Profile Testing
- Provides total loss and dB/km values for full band testing (1260 to 1640
nm)
- Allows CDWM and dense wavelength division multiplexing (DWDM),
transmission band characterization
- Provides water peak (1383 nm area) characterization
- Offers shock- and vibration-proof design (with no moving parts)
- Combined with WDM and PMD functions or with CD and PMD functions
DWDM Maintenance Testing
- Measures channel level, power, and wavelength in the S, C, and L bands
- Provides the most compact DWDM test solution that measures optical
signalto-, noise ratio (OSNR)
- Tests wavelengths from 1260 to 1640 nm or 1485 to 1640 nm
- Offers high wavelength accuracy
- Provides statistics and long-term monitoring
- Offers shock- and vibration-proof design (with no moving parts)
Specifications
| Specifications for Typical
25°C |
Display TFT color, 8.4 in LCD, 800 x
600, high-visibility (standard) Touchscreen,TFT color, 8.4 in LCD, 800
x 600, high-visibility (optional) |
| Storage and I/O
Interfaces |
| Internal memory |
1000 test results |
| Extended memory (optional) |
Minimum 1 GB
(optional) |
| 2x USB V1.1, 1x RJ45 Ethernet |
|
| Power Supply |
|
| Battery type |
Standard removable Li-ion
batteries |
| AC/DC adapter |
Input 100–240 V, 50–60
Hz, Output 19 V DC/3.1 A |
| Operation time |
Up to 11 hrs with standard
display, Telcordia GR-196-CORE |
| Size and Weight |
|
Mainframe with one plug-in
module and battery (L x H x W) |
285 x 195 x 93 mm (11.2
x 7.7 x 3.7 in) |
Mainframe only (without battery and
module) |
2.4 kg (5.3 lb) |
Mainframe (with one plug-in
module and battery) |
3.4 kg (7.5 lb) |
| Environmental
Specifications |
Operating temperature range on mains
(no options) |
–20 to +50°C (–4 to
122°F) |
Operating temperature range
(all options) |
0 to +40°C (32 to
104°F) |
| Storage temperature range |
–20 to +60°C (–4 to
140°F) |
| Humidity, non-condensing |
95% |
| Base Unit Optical Interfaces
(optional) |
| Power Meter |
|
| Power level |
+10 to –60 dBm |
| Calibrated wavelengths |
850, 1310, and 1550
nm |
| Connector type |
Universal push/pull
(UPP |
| Talkset |
|
| Wavelength |
1550 nm ±20 nm |
| Dynamic range |
45 dB |
| Function |
With data/file
transfer |
| Laser safety |
Class 1M laser |
| Connector type |
Field interchangeable |
| Optical Return Loss |
|
| Selectable wavelength |
1310 / 1550 nm |
| Measurement range |
0 dB to 45 dB |
| Measurement uncertainty |
± 1 dB |
| Display resolution |
0.01 dB |
| Visual Fault
Locator |
|
| Wavelength |
635 nm ±15 nm |
| Output power level |
<1 mW |
| Laser safety |
Class 2 laser |
| Connector type |
Universal push/pull
(UPP) |
| Continuous Wave Light
Source |
| Wavelengths (selection) |
1310, 1550, and 1625
nm |
| Output power level |
–3.5 dBm |
| Stability in 15 min |
± 0.02 dB |
| Stability in 8 hrs |
± 0.2 dB |
| Laser safety |
Class 1M laser |
| Connector type |
Field interchangeable |
| Video Inspection Scope (via
USB) |
| Magnification |
250X and 400X, through the
USB port |
MTS/T-BERD Platforms Long Range (LR) OTDR Module
Key Features
- 0.8 m event dead zone for highest network precision
- Point-to-multipoint (P2MP) testing with a combined high dynamic range and
high resolution solution
- Continuous wave (CW) functionality
In today’s telecommunications market, test solutions must be cost effective,
in-crease productivity, and reduce the complexity of field testing. JDSU’s Long
Range (LR) OTDR Module offers a high-performance OTDR test module, which has
been specifically developed in response to these industry
demands.
Configurable at the time of order, the LR OTDR Module offers
multiple wave-length test capabilities (1310, 1490, 1550, and 1626 nm) providing
field technicians with an all-in-one test instrument
The LR OTDR
Module's performance enables effective testing on short haul (access, FTTx,
P2MP), long haul, and very long haul networks.
With the LR OTDR Module’s impressive performance, testing, and
troubleshooting capabilities, the amount of time required to characterize a
fiber network is drastically reduced. Test any fiber link or network
configuration in record time.
- The LR OTDR Module configures itself with its automated functionality and
sets the best-suited acquisition parameters, including optimized acquisition
times, as defined by the instrument.
- Obtain the trace form with the correct auto zoom, evaluate the fiber link,
and save the results in record time!
- Minimize handling errors with the pass/fail indicator. By viewing a quick
snapshot, technicians can easily identify incorrect results.
With the combination of an impressive acquisition time, event dead zone, and
dynamic range, FTTx technicians are able to test through a splitter with
unprecedented accuracy using the LR OTDR Module.
- In compliance with ITU-T G.983.3, the LR OTDR Module provides a
three-wavelength version at 1310/1490nm/1550 nm, expanding its test
capabilities to FTTx/PON.
- Provides splice and connector information at the three PON wavelengths.
- Combines a high dynamic range and short event resolution in order to
characterize short fiber lengths and measure through the splitters.
- Integrates splitter management data in the table results.
Specifications
General (typical at 25°C)
- Weight 0.6 kg (1.1 lb)
- Dimensions (w x h x d) 213 x 124 x 32 mm (8.38 x 4.88 x 1.26 in)
Optical Interfaces
- Applicable fiber SMF 9/125 µm
- Interchangeable optical connectors FC, SC, DIN, ST, LC
Technical Characteristics
- Laser safety class (21CFR) Class 1
- Distance units Kilometers, feet, and miles
- Group index range 1.30000 to 1.70000 in 0.00001 steps
- Number of data points Up to 128,000 data points
- Distance measurement Automatic or dual cursor
- Display range From 2.6 m up to 380 km
- Cursor resolution 1 cm
- Sampling resolution 4 cm
- Accuracy ±1 m ±sampling resolution
±1.10-5 x distance (Excluding group
index uncertainties)
Central Wavelength Pulse Width RMS Dynamic Range
1310 ±20 nm 3 ns to 20 µs 43 dB 1550 ±20 nm 3 ns to 20 µs 41
dB
|