HP Sunrise Agilent CALAN 3010H Sweep Ingress
Condition: Refurbished / Calibrated
Warranty: 90 Day Exchange
This rack mounted headend unit supports up to ten field instruments simultaneously in a return path mode, and an unlimited number of field units as a forward sweep transmitter (Option 050). These functions may be dedicated or combined to allow forward and return sweep in a single unit (Option 052).
MEASUREMENTS | 3010H |
Carrier | |
Channel Scan | |
w/four channel plans | v |
Four Channel | v |
Single Channel | v |
Variable Dwell Time | v |
Average Digital Power | v |
TDMA Power | v |
24 Hour Test w/Sleep Model | v |
Spectrum Scan | v |
Distortion | |
C/N | v |
Hum | v |
Ingress | |
Return Path Spectrum Display | v |
Detection | v |
Monitoring: | v |
Burst Count | v |
Average Noise Power | v |
Spectrum Monitor | v |
Sweep | |
Agile Telemetry Pilot | v |
Forward Sweep Receive | v |
Forward Sweep Transmit | |
Return Path Sweep | v |
Data Management | |
Data Storage - 90 Files | v |
FCC Reporting | v |
Sleep Mode | v |
Graphic File Storage | v |
RS-232 Data Communications | v |
Parallel Printer Port | v |
Printer Support | v |
Ingress Measurements
The 3010R and 3010H now include three unique ingress measurements for ongoing monitoring of burst noise, integrated average noise power in the presence of active TDMA carriers, and spectrum scan. The results of these measurements can be exported via the serial port, or stored in internal history files for review and historical performance comparisons.
Return Path Alignment and Ingress Detection
The 3010H headend unit monitors communication with field units. When ingress interrupts communication, the 3010H instantly detects the problem and transmits a モpictureヤ of the ingress via the forward data pilot that can be viewed on any field unit (2010B/3010B/3010R). This remote capability ensures that field personnel have immediate access to the information required to isolate problems, without the need to call for help or leave the site. The result is faster problem resolution and more efficient use of field resources.
Digital Power Measurement
Digital signals cannot be measured with conventional methods used for video carriers because their power is spread over a band unique to each form of digital signal. CaLan products incorporate a digital signal measurement capability ヨ technicians need only enter the center frequency, span and format for each digital signals in the unitメs channel table. The family also provides accurate average power measurement for return path TDMA (bursted) carriers.
Digital signal power is the total average power over a channel bandwidth around its center frequency. The 3010R, 3010H, 3010B and 2010B can adapt to the unique bandwidth power characteristics of digital signals to make measurements as simple as reading a number on the display.
Return Sweep (3010R/3010H)
Return path maintenance is critical to optimizing systems for two-way services. The 3010R and 3010H incorporate DigiSweep technology, the industryメs fastest, high resolution, digital services compatible sweep. DigiSweepメs five-microsecond sweep pulses allow placement close to digital signals without interference. DigiSweep technology is compatible with cable modems, telephony, interactive TV, digital music services and Internet communications.
An easy-to-use insertion point (IP) automatically adjusts the sweep source level to compensate for varying test point losses. This, and other key features, allows accurate return path alignment in a matter of minutes.
DUAL PATH CAPABILITIES
The dual path option for the 3010H enables the same headend unit to perform both forward and return path testing, increasing bandwidth usage efficiency while saving valuable headend space and lowering test equipment costs. The headend unit (3010H with Option 052) cycles through transmission of a sweep signal on the forward path and monitoring of the signals on the return path. This cycle permits multiple field units to perform both forward and return sweep at the same time.
For applications that only require forward sweep, operators can utilize the 3010B and 3010H with Option 050, while still supporting future upgrades. This solution offers all SLM capabilities, with the addition of forward sweep and a telemetry pilot that can be adjusted to changing system requirements.
Specifications:
SWEEP SOURCE AMPLITUDE ACCURACY
Output Range: +10 dBmV to +50 dBmV in 1 dB steps
Absolute Accuracy: ±1.5 dB
Relative Accuracy: ±1 dB
Harmonic Output: <-30 dBc, 5 to 10 MHz; <-35 dBc, 10 to 1000 MHz
Spurious Output: <-30 dBc
Source Output Return Loss: >15 dB
Source Blanking During Sweep: >60 dBc
SWEEP CHARACTERISTICS
Sweep Frequency Range: 5 MHz to 1 GHz
Sweep Width: Continuously variable
Frequency Resolution: 222 to 401 data points
Sweep Time: Sweep table dependent 650 msec (typical)
DATA TRANSMISSION PILOT CHARACTERISTICS
Range: 5 MHz - 1 GHz
Programmable Resolution: 10 kHz
Data Carrier Modulation Bandwidth: -30 dBc <750 kHz, - 50 dBc <1.8 MHz
Proximity of Equal Amplitude CW Carrier Without Communications Interruption: <300 kHz
MEASUREMENT SPECIFICATIONS
Digital Signal Power Levels Formats: QAM, QPR (DMX), QPSK, and VSB, bursted
Amplitude Accuracy: ±1.5 dB (typical)
TDMA Measurement Range
Burst width: >50 µ sec
Burst repetition rate: <1.5 sec
Frequency
Range: 5 MHz to 1 GHz
Source Accuracy: ±25 kHz
Resolution: 10 kHz
Tuning Configuration: Standard, off the air, HRC, IRC, PAL, SECAM, user-defined
IF bandwidth: 230 kHz
Video bandwidth 300 kHz, automatic 10 Hz C/N
Amplitude Accuracy For Sweep and Carrier Measurements
Range: +70 to -45 dBmV
Typical Accuracy: ±1.0 dB
Calibrator: ±0.25 dB at 113.36 MHz, ±0.2 MHz
Frequency Flatness: ±0.5 dB
Internal Preamp On: ±1.0 dB
Attenuator: ±0.5 dB
Log Linearity: ±0.5 dB
Resolution: 0.1 dB
Input Impedance: 75 ohm
Input Match: 0 dB attenuation, >14 dB; all other settings, >20 dB
Ingress Measurements
Burst Count
Minimum Burst Width: <30 µSec
Capture Ranges: < 100 µSec - < 1 Sec
Sec in decades, < 3 Sec and > 3 Sec
Average Noise Power
Maximum TDMA Pulse Width Not Captured: >500 mSec
Hum
Range: 0.5 to 5%
Resolution: 0.1%
Accuracy: ±0.2%, ±30% of reading
Carrier-to-Noise Ratio
Range: 50 dB
Accuracy: ±2 dB
Repeatability: ±1 dB
Fiber Optic Power Meter Option
Wavelength: 1310 and 1550 nm
Measurement Range: +20 to -38 dBm, 1310 nm; +18 to -38 dBm, 1550 nm
Resolution: 0.1 dB
Accuracy: ±5%
Display: dB, dBm, nW, mW
Connector Styles: ST, FC, SC, biconic, D4, SMA, or bare fiber, rotary splice, RM
GENERAL
Internal Memory For:
Data and Graphics Files: Up to 90
Channel Plans: 4
Reference Traces: 12 (3010B, R, H only)
Sweep Table: 4 (3010B, R, H only)
Printer Output of Screen Display: Parallel and RS-232
Temperature
Operating 0°C to +55°C
Storage: -20°C to +70°C
Size
5.25"h x 19"w x 11.5"d
Weight
9.5 lb
Power
90 VAC to 264 VAC, 47 to 63 Hz 20 VA max
Display
Area: 5.0 in x 1.33 in
Resolution: 240 x 64 pixels
Type: LCD with EL back light
For full Sunrise Telecom Calan 3010H product specifications, please click here: Sunrise Telecom Calan 3010H
Sunrise Agilent HP CALAN 3010H Sweep/Ingress Analyzer
Installed Options:
- Opt ABA: U.S. Quick Users Guide (English localization)
- Opt 052: Dual Path Capabilities
- Opt 061: Switch Control
Time proven product for maintaining the networks of today and tomorrow.
Includes Accessories As Listed
Agilent 3010H CALAN CATV Meter 3010H-CALAN CATV Meter Models On Sale Warranty Calibration Backed by The Best Service and Lowest Prices in the Industry.
BC# 16452
- HP CALAN 3010H Sweep/Ingress Analyzer (BC# 16452) w/ Options
- Opt ABA: U.S. Quick Users Guide (English localization)
- Opt 052: Dual Path Capabilities
- Opt 061: Switch Control
- Coax Cable
- Power Cord
- RS232 PC Interface Cable
- User Manual On CD-ROM