HP 3010R CALAN Sweep / Ingress Analyzer 85962A
Condition: Refurbished / Calibrated
Warranty: 90 Day Exchange
Whether for routine maintenance or new interactive network installations, CaLan products offer a range of solutions. These products cover the entire 5 MHz to 1 GHz frequency range with exceptional speed ヨ 60 channels of visual and aural carriers in less than 2 seconds.
3010R
This portable field instrument includes forward sweep, return sweep and SL capabilities. The 3010R can also function as a headend unit for troubleshooting intermittent problems in specific network segments.
Cost-Effective Signal-Level Measurement
The portable, rugged 2010 SLM Plus provides an affordable, entrylevel option for customers. Measurements include carrier amplitude, digital channel power, carrier-to-noise ratio, and hum. The fourchannel adjustment mode allows technicians to view four channels at a glance, for a quick, system-wide check of the lowest, highest and AGC pilot frequencies.
Digital Power Measurement
Digital signals cannot be measured with conventional methods used for video carriers because their power is spread over a band unique to each form of digital signal. CaLan products incorporate a digital signal measurement capability ヨ technicians need only enter the center frequency, span and format for each digital signals in the unitメs channel table. The family also provides accurate average power measurement for return path TDMA (bursted) carriers.
Digital signal power is the total average power over a channel bandwidth around its center frequency. The 3010B can adapt to the unique bandwidth power characteristics of digital signals to make measurements as simple as reading a number on the display.
Data Storage
The 3010R can store up to 90 history files in any one of six formats: level measurements, normalized channel scan traces, sweep traces, spectrum scan traces, and ingress measurement results. Each file includes time and date stamps with a 40-character, user-defined label.
MEASUREMENT SPECIFICATIONS
Digital Signal Power Levels Formats: QAM, QPR (DMX), QPSK, and VSB, bursted
Amplitude Accuracy: ±1.5 dB (typical)
TDMA Measurement Range
Burst width: >50 µ sec
Burst repetition rate: <1.5 sec
Frequency
Range: 5 MHz to 1 GHz
Source Accuracy: ±25 kHz
Resolution: 10 kHz
Tuning Configuration: Standard, off the air, HRC, IRC, PAL, SECAM, user-defined
IF bandwidth: 230 kHz
Video bandwidth 300 kHz, automatic 10 Hz C/N
Amplitude Accuracy For Sweep and Carrier Measurements
Range: +70 to -45 dBmV
Typical Accuracy: ±1.0 dB
Calibrator: ±0.25 dB at 113.36 MHz, ±0.2 MHz
Frequency Flatness: ±0.5 dB
Internal Preamp On: ±1.0 dB
Attenuator: ±0.5 dB
Log Linearity: ±0.5 dB
Resolution: 0.1 dB
Input Impedance: 75 ohm
Input Match: 0 dB attenuation, >14 dB; all other settings, >20 dB
Ingress Measurements
Burst Count
Minimum Burst Width: <30 µSec
Capture Ranges: < 100 µSec - < 1 Sec
Sec in decades, < 3 Sec and > 3 Sec
Average Noise Power
Maximum TDMA Pulse Width Not Captured: >500 mSec
Hum
Range: 0.5 to 5%
Resolution: 0.1%
Accuracy: ±0.2%, ±30% of reading
Carrier-to-Noise Ratio
Range: 50 dB
Accuracy: ±2 dB
Repeatability: ±1 dB
For full Agielnt CALAN 3010R product specifications, please click here: Agilent CALAN 3010R
Agilent HP CALAN 3010R Sweep/Ingress Analyzer CATV Analyzer
Installed Options
- 020: Fiber Optic Power Meter
- ABA: U.S. Quick Users Guide (English localization)
Includes Carrying Case & Accessories As Listed
3010
Agilent 3010R CALAN CATV Meter 3010R-CALAN CATV Meter Models On Sale Warranty Calibration Backed by The Best Service and Lowest Prices in the Industry.
BC# 20503
- Sunrise Telecom CALAN 3010R Sweep/Ingress Analyzer CATV Analyzer 85962A w/ Options: (BC# 20503)
- 020: Fiber Optic Power Meter
- ABA: U.S. Quick Users Guide (English localization)
- AC Adapter/Charger
- Power Cord
- RS232 PC Interface Cable
- User Manual On CD-ROM