Anritsu CMA4500 5224 kit with accessories

Anritsu CMA4500 5224 SM Long Haul Fiber OTDR

EXFO TG-300B kit with accessories

EXFO TG-300B FiberFinder Tone Generator

Agilent HP E6000C E6008B SM Fiber Long Haul OTDR

$0.00
Availability: Out of stock
SKU
4B33

Condition: Refurbished / Calibrated

Warranty: 90 Day Exchange

Request a Quote for

Have Questions or doubts? Submit the following request and expect our detailed quote within 24 hours!

we are commited to win your business!

The Agilent Mini-OTDR is the best selling product in Agilent's portfolio of Optical Network Test Solutions for the installation, maintenance and operation of fiber networks.

The Mini-OTDR is designed to provide its users with the fastest tool available for installing and commissioning multiple fiber links and locating faults for fiber maintenance. This is accomplished through high measurement performance and an award winning simple user interface.

Fiber Break Locator to quickly find breaks and bends.

Locate and characterize splice and connector losses.

Multifiber testing for fast high-count cable qualification.

Perform power and loss measurement with the built-in light source and the power meter module.

Graphical representation of measurement results in event tables, showing loss and reflection, and pass/fail results.

Visual Fault Finder to check patch cords for light leakage.

Characteristics:

Horizontal Parameters

  • Start-km:
  • 0 km to 400 km Span: 0.1 km to 400 km
  • Readout resolution: 0.1 m
  • Minimum sample spacing: 4 cm
  • Refractive index: 1.00000 to 2.00000
  • Length unit: km, ft, or miles
  • Measurement points: up to 64000

Vertical Parameters

  • Vertical scale
  • 0.1 to 10.0 dB/Div Read-out resolution: 0.001 dB
  • Reflectance range: 14 dB to 60 dB
  • Backscatter coefficient: 10 to 70 dB at 1 s


Pulsewidth

  • You can select any of the following pulsewidths: 10 ns, 30 ns, 100 ns, 300 ns, 1 s, 3 s, and 10 s (all modules). You can also select 5 ns for E6003C, 5A, 9A modules, and 20 s for E6003B, E6003C, E6008B, and E6013A.
  • With the E6005A module, you can select a pulsewidth from 5 ns to 100 ns at 850 nm, and from 5 ns to 10 s at 1300 nm.
  • With the E6009A module, you can select a pulsewidth from 5 ns to 100 ns at 850 nm, and from 5 ns to 1 s at 1300 nm.


Storage

  • 3.5 floppy disk drive: for high density 720/1440 kByte floppy disks. MS-DOS format compatible. Reduced operating temperature of 5C to 45C, with 35% to 80% humidity at 40C. Memory Card: PCMCIA Type II. 440 MB with up to 13000 traces (typical with 64000 data points).
  • Internal memory: SRAM up to 2 MB. Up to 300 traces (typical) with 4000 data points


OTDR Trace Formats:

  • Trace format: compliant to the following Bellcore/Telcordia OTDR trace formats:
    • GR 196, Revision 1.0
    • GR 196, Revision 1.1
    • SR-4731 Revision 2.0
  • Trace Information: 5 comment labels of up to 15 alphanumeric characters, and 5 comment fields of up to 41 alphanumeric characters are provided for each trace.
  • Real-time clock and date


Scan Trace:

Type of events:

  • Reflective and nonreflective. Maximum number of events: 100.
  • Threshold for non-reflective events: 0.0 to 5.0 dB, selectable in 0.01 dB steps.
  • Threshold for reflective events: - 14.0 to ?65.0 dB, selectable in 0.1 dB steps.
  • Threshold for fiber breaks: 0.1 to 10 dB, selectable in 0.1 dB steps.
  • Fiber End Threshold: 0.1 to 20 dB, selectable in 0.1 dB steps.
  • Display Color or monochrome VGA-LCD: 18.3 cm (7.2?)
  • Display points: 640 x 480 Points
  • Measurement update rate: two measurements per second in refresh mode


Interfaces:

  • RS232C: Maximum transmission rate: 115200 bps Transmission time at 115200 bps for trace data: 4000 points at approx. 1 second; 64000 points at approx. 4 seconds.
  • Centronics: Standard parallel port (SPP).
  • Keyboard: PS2 (Min-DIN). For English Standard, PS2, or AT keyboard.


General:

  • Automatic setup analysis
  • Instrument settings: storage and recall of user-selectable instrument settings.
  • Laser safety class: All OTDR laser sources specified by this data sheet are classified as Class 1M according to IEC 60825-1 (2001).
  • The Visual Fault Finder Sub-Module E6007A complies with Class 2 according to IEC 60825-1 (2001).
  • All laser sources comply with 21 CFR 1040.10 except for deviations pursuant to Laser Notice No. 50, dated 2001-July-26

Built-in Applications:

  • Automatic Multi Fiber Test
  • Pass/Fail Test
  • Fiber Break Locator
  • Power Meter / Loss Test mode 1
  • Visual Fault Finder mode 1
  • Optical Return Loss
  • End to End Loss
  • Easy OTDR
  • OTDR Training
  • OTDR Assistant


Environmental

  • Operating Temperature: 0 to 50 degees C Storage Temperature: 40 to +60 degrees C
  • Humidity: 95% R.H from 0 to 40 degrees C


Power

  • AC: 100 240 Vrms
  • 10% 50 60 Hz DC: 16 24 V
  • External Battery: NiMHtypically 8 hours continuous operation (minimum 4 hours) with Option #006. Charging time < 3 hours, non-operating
  • Low battery indicator
  • Battery charge status

 

 E6008B Specifications:

Central Wavelength 1310 nm ± 25 nm/1550nm ± 5 nm
Applicable Fiber single-mode
Pulsewidth 10 ns 100 ns 1 µs 10 µs 20 µs
Dynamic Range [dB] 24/22 29/27 35/34 42/41 45/43
Event Deadzone 3 m
Attenuation Deadzone 10/12m

 

 E6006A Power Meter Module Specifications:

 
Sensor Element InGaAs
Wavelength Range 800 - 1650 nm
Calibrated Wavelengths 850/1300/1310/1550/ nm
Power Range +10 to -70 dBm
Max. Input Power +13 dBm / 20 mW
Display Resolution 0.01 dB
Display Units dBm, dB, mW, µW, nW, pW
Display Contents Calibrated in nm
Modulation frequency in Hz
Reference vaule in dB
Applicable Fiber Type 9/1250 µm, 50/125 µm, 62.5/125 µm



For full Agilent E6000C E6008B E6006A product specifications, please click here: Agilent E6000C E6008B E6006A

Agilent HP E6000C OTDR Mainframe With
E6008B SingleMode Long Haul 1310 / 1550nm Fiber OTDR Module w/
E6006A Power Meter Module & E6007A VFL

Dynamic Range:
1310 / 1550 nm : 45 / 43 dB

Power Meter:
- 850nm
- 1300nm
- 1310nm
- 1550nm

Includes Carrying Case & Accessories As Listed!

Agilent E6000C E6008B E6006A E-6000C E-6008B E-6006A OTDR Models On Sale Warranty Calibration Backed by The Best Service and Lowest Prices in the Industry.

BC# 19814 20496 20499 20957

  • Agilent E6000C OTDR Mainfame (BC# 19814)
  • Agilent E6008B SingleMode Fiber Long Haul OTDR Module (BC# 20496)
    • SM OTDR Source:
      • 1310nm
      • 1550nm
      • FC Connector For Source
  • Agilent E6006A Power Meter Module (BC# 20499)
    • Power Meter:
      • 850nm
      • 1300nm
      • 1310nm
      • 1550nm
    • FC Connector For Power Meter
  • Agilent E6007A VFL (BC# 20957)
  • (2) SM FC-ST Fiber Cables
  • (4) Fiber Cleaning Wipes 
  • AC Adapter/Charger
  • Power Cord
  • RS232 PC Interface Cable
  • User Manual On CD-ROM
  • Carrying Case