Agilent E6000A Mini OTDR Mainframe
The Agilent Mini-OTDR is the best selling product in Agilent's portfolio of
Optical Network Test Solutions for the installation, maintenance and operation
of fiber networks.
The Mini-OTDR is designed to provide its users with the fastest tool
available for installing and commissioning multiple fiber links and locating
faults for fiber maintenance. This is accomplished through high measurement
performance and an award winning simple user interface.
* Fiber Break Locator to quickly find breaks and
bends. * Locate and characterize splice and connector
losses. * Multifiber testing for fast high-count cable
qualification. * Perform power and loss measurement with
the built-in light source and the power meter module. *
Graphical representation of measurement results in event tables, showing loss
and reflection, and pass/fail results. * Visual Fault
Finder to check patch cords for light leakage.
Characteristics
Horizontal Parameters
* Start-km: * 0 km to 400 km Span:
0.1 km to 400 km * Readout resolution: 0.1
m * Minimum sample spacing: 4 cm *
Refractive index: 1.00000 to 2.00000 * Length unit: km,
ft, or miles * Measurement points: up to 64000
Vertical Parameters
* Vertical scale: * 0.1 to 10.0
dB/Div Read-out resolution: 0.001 dB * Reflectance range:
14 dB to 60 dB * Backscatter coefficient: 10 to 70 dB at 1
s
Pulsewidth
You can select any of the following pulsewidths: 10 ns, 30 ns, 100 ns, 300
ns, 1 s, 3 s, and 10 s (all modules). You can also select 5 ns for E6003C, 5A,
9A modules, and 20 s for E6003B, E6003C, E6008B, and E6013A.
With the E6005A module, you can select a pulsewidth from 5 ns to 100 ns at
850 nm, and from 5 ns to 10 s at 1300 nm.
With the E6009A module, you can select a pulsewidth from 5 ns to 100 ns at
850 nm, and from 5 ns to 1 s at 1300 nm.
Storage
* 3.5 floppy disk drive: * for high
density 720/1440 kByte floppy disks. MS-DOS format compatible. Reduced operating
temperature of 5C to 45C, with 35% to 80% humidity at 40C. Memory Card: PCMCIA
Type II. 440 MB with up to 13000 traces (typical with 64000 data
points). * Internal memory: SRAM up to 2 MB. Up to 300
traces (typical) with 4000 data points
OTDR Trace Formats
Trace format: compliant to the following Bellcore/Telcordia OTDR trace
formats:
* GR 196, Revision 1.0 * GR 196,
Revision 1.1 * SR-4731 Revision 2.0.
* Trace Information: 5 comment labels of up to 15 alphanumeric characters, and 5
comment fields of up to 41 alphanumeric characters are provided for each
trace. * Real-time clock and date
Scan Trace
* Type of events: * reflective and
nonreflective. Maximum number of events: 100. * Threshold
for non-reflective events: 0.0 to 5.0 dB, selectable in 0.01 dB
steps. * Threshold for reflective events: - 14.0 to ?65.0
dB, selectable in 0.1 dB steps. * Threshold for fiber
breaks: 0.1 to 10 dB, selectable in 0.1 dB steps. * Fiber
End Threshold: 0.1 to 20 dB, selectable in 0.1 dB steps.
* * Display Color or monochrome VGA-LCD: 18.3 cm
(7.2?) * Display points: 640 x 480
Points * Measurement update rate: two measurements per
second in refresh mode
Interfaces
RS232C:
* Maximum transmission rate: *
115200 bps Transmission time at 115200 bps for trace data: 4000 points at
approx. 1 second; 64000 points at approx. 4 seconds. *
Centronics: Standard parallel port (SPP). * Keyboard: PS2
(Min-DIN). For English Standard, PS2, or AT keyboard.
General
* Automatic setup analysis *
Instrument settings: storage and recall of user-selectable instrument
settings. * Laser safety class: All OTDR laser sources
specified by this data sheet are classified as Class 1M according to IEC 60825-1
(2001).
The Visual Fault Finder Sub-Module E6007A complies with Class 2 according to
IEC 60825-1 (2001).
All laser sources comply with 21 CFR 1040.10 except for deviations pursuant
to Laser Notice No. 50, dated 2001-July-26
* Recommended module recalibration
period: * 2 years. (OTDR Modules and Power Meter only)
Dimensions: 194 mm H, 290 mm W, * 75 mm D (7.7? x 11.4? x
3.0?). * Weight: net < 2.9 kg (6.4 lbs), typical,
including battery pack and OTDR module.
Built-in Applications
* Automatic Multi Fiber Test *
Pass/Fail Test * Fiber Break Locator
* Power Meter / Loss Test mode 1 * Visual Fault Finder
mode 1 * Optical Return Loss * End
to End Loss * Easy OTDR * OTDR
Training * OTDR Assistant
Environmental
* Operating Temperature: * 0 to 50
degees C Storage Temperature: 40 to +60 degrees C *
Humidity: 95% R.H from 0 to 40 degrees C
Power
* AC: 100 240 Vrms * 10% 50 60 Hz
DC: 16 24 V * External Battery: NiMHtypically 8 hours
continuous operation (minimum 4 hours) with Option #006. Charging time < 3
hours, non-operating * Low battery
indicator * Battery charge status
E6003A Specifications:
Module
|
E6003A
|
Central Wavelength
|
1310nm ± 25 nm / 1550nm ± 25
nm
|
Applicable Fiber
|
Single Mode
|
Pulsewidth
|
10ns 10ns 1us 10us
|
Dynamic Range [dB]
|
19/17 24/22 30/29 35/34
|
Event Deadzone
|
3 m
|
Attenuation Deadzone
|
10/12m
|
Agilent E6006A Power Meter Submodule
Characteristics
Sensor element: InGaAs
Wavelength range: 800 -
1650 nm
Calibrated wavelengths: 850 nm, 1300 nm, 1310 nm, 1550 nm, 1625
nm (special wavelengths on request).
Power range: +10 to -70
dBm
Max. input power (damage level): +13 dBm/20 mW
Display
Resolution: 0.01 dB
Display Units: dBm, dB, mW, µW, nW, pW
Display
Contents • Calibrated - in nm • Modulation frequency in Hz • Reference
value in dB
Display Updates per second: 3
Optical input:
User-exchangeable Connector Interface
Applicable fiber type: 9/125 µm,
50/125 µm, 62.5/125 µm
Specifications
Uncertainty at reference conditions: ±
3%
Power level: - 20 dBm Continuous Wave (CW)
Wavelength: 1300±3
nm, 1310±3 nm, 1550±3 nm
Fiber type: 50/125 µm graded index,
Agilent/HMS-10 connector
Spectral bandwidth: up to 10 nm
Ambient
temperature: +18 to + 28 °C
At day of calibration (add 0.3% for aging of
over one year; add 0.6% for aging of over two years).
Total uncertainty:
± 5% ± 0.5 nW (1310, 1550 nm)
Power level: +0 to ?50 dBm Continuous Wave
(CW)
Wavelength: 850±3 nm, 1300±3 nm, 1310±3 nm, 1550±3 nm,
Fiber
type: SM to 50µm graded index (add 2% to total uncertainty for fiber
62.5µm).
Characteristics
• Automatic Zeroing Circuitry • Automatic
Ranging • Modulation frequency recognition (270 Hz, 1 kHz, 2 kHz) is
available at power level between +10 and ?45 dBm (peak amplitude). • Dual
Wavelength measurement is available at power levels between +10 and ?45 dBm
(peak amplitude). • Wavelength encoding recognition (350 Hz, 550 Hz) is
available at power levels between +10 and ?45 dBm (peak amplitude). •
Reference value is presettable from +30 to ?80 dBm • Each calibrated
wavelength has its own reference memory. • The actual display content can be
transferred to reference memory(DISP?REF). • Hold Data functionality
General Specifications
Dimensions: ca. 120 mm H x
40 mm W x 25 mm D (4.7? x 1.6? x 1.0?) Weight: <130g.
Operating Temperature: 0 to +50 °C
Storage Temperature: -40 to +60
°C
Humidity: 95% R.H. from 0°C to 40°C non cond
|