Agilent N1610A Service Advisor Tablet w/ N1660A
Condition: Refurbished
Warranty: 90 Day Exchange
Agilent N1610A Service Advisor Test Tablet
Outside Plant
With its powerful Graphical User Interface (GUI) and its simple and easy operation, the Service Advisor Portable Test Tablet is the ideal tool for the outside plant. Its intuitive user interface allows the operator to quickly install and maintain service. Battery power allows operation where AC power is not available or convenient. Optional software application packages enable technicians to store and recall data and information in databases, spreadsheets and documents. The rugged design of the Service Advisor Portable Test Tablet enables it to stand up to years of demanding field use.
Verification
Technicians and engineers can use the Service Advisor Portable Test Tablet to develop and verify network elements in the laboratory. Its consistent user interface and modular design help users rapidly switch test tasks. The advanced operating system enables users to develop test sequences which can be rapidly rolled out in the field. With its SCPI command line interface control, users can easily create test sequences which operate the test set from a serial port, a modem or a LAN.
Central Office:
Central Office (CO) users will find the power and flexibility of the Service Advisor Portable Test Tablet ideal for installing and maintaining services. The simple GUI operation enables wide first tier field deployment and 2nd/3rd tier regional support. With flash memory capability, CO personal can create test suites which can be downloaded into the test set for field testing. Once the data is collected it can then be recalled, analyzed and transferred to a PC.
Specifications
Modular:
* Supports 2 single modules or 1 dual test module
* Hot swappable
Display:
* 7.2" diagonal 640 x 480 color VGA backlighted dual scan LCD
User Interface:
* Graphical User Interface
* Touchscreen
* Navigation Keys: Direction ( ¯ ¬ ® ),Enter, Display/Audio
* LEDs: On/Off (green), External Charging/
* Battery Low (green, red)
* Stylus
Memory:
* RAM: 16MB
* Flash-ROM: 12MB
Operating System:
* Microsoft Windows® CE 2.0 or later
* Flash File System for non-volatile results and configuration storage
Processor:
* Hitachi SH-3
* Continuous time and date clock
Remote Control:
* Remote Services provides SCPI command line interface (option)
PC-Cards Supported:
* Type-I and II
* V.90 56K Modem PC Card (option)
* 10BaseT Ethernet LAN PC Card (option)
* 10MB Flash-ROM PC Card (option)
Data and File Management:
Local:
* Store and recall results
* Store and recall configurations and test suites
Remote:
* via Service Advisor Companion software (compatible with Windows® 95/ 98, Windows NT® 3.51 or later)
Upload results:
* Upload and download configurations and test suites
* Download program Flash-ROM updates
_________________________________________________________________________________________
N1660A Dual DS1/0 Tester Module
Speed T1 installations and maintenance troubleshooting with one-touch, full duplex analysis. Agilent's Dual DS1/0 test module for the Service Advisor test tablet simplifies T1 and DS0 testing by providing complete analysis of line conditions and status on both sides of the circuit.
View All Key Results On One Screen
Quickly and easily synchronize to full-duplex T1 circuits. Simultaneously view the status of both sides of the T1. The Dual Line DS1/0 Test Module features color coded "soft LED" indicators, color coded meters providing results and summary data.
Simultaneously Monitoring and BER Testing
The Dual Line DS1/0 Test Module features a full compliment of standard BERT patterns and flexible user-programmable patterns. BER test on both directions of the circuit.
Automate BER Testing Sequences
Quickly perform multi-pattern and bridge tap test sequences. Inject errors. The Dual Line DS1/0 Test Module features user-programmable BER test sequences and status display area.
Complete Loopback Capabilities
Control loopback activation and deactivation. Supports in-band and out-of-band loopcodes. Use standard and user-programmable loop codes.
Osciloscope Views of the Received T1 Signal
The Dual DS1/0 Test Module's pulsemask measurement option provides a scope view of the T1 signal. Quickly compare with industry-standard masks. Measure standard parameters for further detailed analysis.
Ongoing Background Event Logging
Document turn-ups, corrective action, and troublescan lines. Scroll through results. Date and time stamp results. Save results in file.
Troubleshoot PBX Signaling
Display on-hook/off-hook status of all 24 channels. Test E-M, ground start, loopstart, or mixed trunks. View time and date of events.
INCLUDED ACCESSORIES
*(1) Agilent N1610A Portable Service Advisor Tablet
*(1) Agilent Dual DS1/0 Tester N1660A Module
*(1) New Battery
*(1) AC Adapter
*(1) Carrying Bag
For full Agilent N1610A specifications, please click here: Agilent N1610A