Siemon MT-RJ kit with accessories

Siemon Cabling MT-RJ Fiber Termination System

EXFO FiberBasix 500 kit with accessories

EXFO FiberBasix FBK-506 SM MM Fiber Optic Loss Test Set (ELS-500-12D-23BL / EPM-502-VFL)

Anritsu MD6430A Network Data Analyzer w/ MU643000C

$1,495.00
Availability: Out of stock
SKU
1H189

Condition: Refurbished / Calibrated

Warranty: 1 YEAR WARRANTY

Request a Quote for

Have Questions or doubts? Submit the following request and expect our detailed quote within 24 hours!

we are commited to win your business!

MD6430A Network Data Analyzer

The MD6430A Network Data Analyzer can measure errors on 13 different interfaces from leased lines (64 kbit/s to 6.3 Mbit/s), ISDN (BRI, PRI) and V/X series interfaces, making it suitable for installation and maintenance of a variety of networks. Measurements include bit errors, alarms, delay time, frequency, digital level measurements, user pattern send/trace, etc., all of which can be displayed on the large color LCD. Error performance (ITU-T G.821, G.826, M.2100) is available with various pseudorandom patterns, and user patterns up to 1024 characters. Frame Relay measurement function, ISDN signaling function (option) and a simultaneous two-channel monitoring function is also provided. Single button ?quick? function and touch-screen ensure easy operation. This unit offers the user sophisticated functions required for installation and maintenance in a small compact unit.

Features:

Many applications ranging from low-speed modems to high-speed digital lines
 The MD6430A can evaluate the quality of lines ranging from low-speed modems to high-speed digital lines spanning 50 bit/s to 10 Mbit/s and also supports modern ISDN and frame relay protocols.

Support for various interfaces
The MD6430A supports G.703 64k, I.430/I-430a 192k, G.703/G.704/I.431 1.5M, 2M, 2M CMI, 6.3M, V.24/V.28, V.35, V.36, RS-449, X.20, X.21, TTL/CMOS interfaces in a number of optional interface units designed to meet customer needs.



? Powerful measurement functions
Various measurements, such as error, alarm, clock slip, delay, frequency, and digital level can be performed as well as the ability to send user patterns with tracing functions.

? Simultaneous error measurement of various error parameters
The error count (bit error, parity error, and CRC error, etc.), error rate, block error count, block error rate, clock slip count, clock slip seconds, character error count, error performance (G.821, G.826, M.2100), synchronization loss, and alarm seconds can be measured simultaneously.

Frame relay measurements
Frame relay network connections (conforming to PVC and ITU-T Q.933 Annex A) can be tested by the MD6430A. The user can also monitor the congestion status such as FECN, BECN, and CLLM.

? Optional ISDN signaling functions (BRI, PRI)
The unit can be connected to ISDN networks so that both voice communication and error measurement can be performed.

? Measurement between different interfaces
Measurements can be performed between different interfaces by setting the transmitting and receiving interfaces.

Simultaneous two-line monitoring
Simultaneous monitoring of two lines permit error measurement to be performed on the T and R line(CRC error, code error, HDLC error, etc.) and alarm detection.

Error data analysis and storage functions
Error data can be collected in log or histogram formats. This data can also be stored in internal memory or on a floppy disk for later analysis.

Convenient quick functions
Once the measurement settings are stored in internal memory, they can be recalled and displayed just by pressing the Quick key. Up to 10 setting conditions can be stored in this way.

Touch-screen
The touch-screen, large color LCD, and pop-up menus provide a much better GUI operating environment.

? Battery operation
When a commercial power supply is not available, the optional battery pack provides operation for up to 3 hours, and 5 hours in power save operation.

Specifications:

 
Interface High speed: G.703 64k, I.430/I430-a 192k, G.703/G.704/I.431 1.5M*1,* 2, G.703/G.704/I.431 2.0M*1,* 3, 2M CMI*1,*2,
G.703/G.704 6M*1,* 2 (2-wire simultaneous monitoring)
Low speed: V.24/V.28, V.35, V.36, RS-449, X.20, X.21, TTL/CMOS (Send/receive simultaneous monitoring)
Clock
(High-Speed Interface)
Internal clock: 64 kbit/s, 1.544 Mbit/s*1,*2, 2.048 Mbit/s, 6.312 Mbit/s*1,*2 (accuracy =±5 ppm)
External clock: 64k + 8k or slave sync to received data (slave oscillation range: =±100 ppm)
Code Law
(High-Speed Interface)
G.703 64k: AMI
I.430/I430-a 192k: AMI
G.703/G.704/I.431 1.5M: AMI/B8ZS*1,*2
G.703/G.704/I.431 2.0M: AMI/HDB3*1,*3
2M CMI: CMI
G.703/G.704 6M:B8ZS*1,*2
Impedance 64k: 110 ?/HIGH, 192k: 50/100 ?/HIGH, 1.5M:100 ?/HIGH, 2 M:75/120 ?/HIGH, 2M CMI: 110 ?/HIGH, 6M: 75 ?/HIGH
Frames
(High-Speed Interface)
G.704/I.431 1.5M*1,* 2: 12MFP (G.704), 24MFP (G.704), 24MFP (NTT), unframe
G.704/I.431 2.0M*1,* 3: 16MFP (30B + D), 16MFP (31B), 2MFP (30B + D), 2MFP (31B), Unframe
2M CMI*1,* 2: PBX (TTC), CRV, ST (send only), unframe
G.704 6M*1,* 2: 4MFP (G.704), unframe
Data Bit Rate
(High-Speed Interface)
64k x n: 64 to 6272 kbit/s (n =1 to 98*4, sequential or mixed configuration may be selected.)
56k (1-7) x n: 56 to 5488 kbit/s (n =1 to 98*4)
56k (2-8) x n: 56 to 5488 kbit/s (n =1 to 98*4) 8k x n: 8, 16, 32 kbit/s
2.4k x n: 2.4 to 48 kbit/s (n = 1 to 20, sequential or mixed configuration may be selected for X.50 20 multiframe.)
0.6k x n: 0.6 to 48 kbit/s (n = 1 to 80, sequential or mixed configuration may be selected for X.50 80 multiframe.)
Others: Signaling, 1.544 Mbit/s
Send Clock
(Low-Speed Interface)
Internal clock
Send clock Sync (ST1): 50 bit/s to 10 Mbit/s (5 bit/s steps. However, V.24/V.28 and X.20 up to 200 kbit/s) (low-speed interface)
Async: 50, 75, 100, 110, 150, 200, 256, 300, 400, 500, 512, 600, 768, 800, 1k, 1.2k, 1.6k, 1.8k, 2k, 2.4k, 2.56k, 3k, 3.2k, 3.6k, 4.8k, 7.2k, 8k, 9.6k, 12k, 12.8k, 14.4k, 16k, 16.8k, 19.2k, 28.8k, 32k, 38.4k, 46k, 48k, 50k, 56k, 56.6k, 64k, 72k, 76.8k,115.2k (bit/s)
Self oscillation accuracy: =±5 ppm
External clock (ST2, RT): Frequency for each interface of 50 to10 Mbit/s (ST2 may be inverted.)
Recieve Clock
(Low-Speed Interface)
External clock (RT): Frequency for each interface of 50 to 10 Mbit/s (May be inverted)
Receive clock Internal clock (Async): (low-speed interface) 50, 75, 100, 110, 150, 200, 256, 300, 400, 500, 512, 600, 768, 800, 1k, 1.2k, 1.6k, 1.8k, 2k, 2.4k, 2.56k, 3k, 3.2k, 3.6k, 4.8k, 7.2k, 8k, 9.6k, 12k, 12.8k, 14.4k, 16k, 16.8k, 19.2k, 28.8k, 32k, 38.4k, 46k, 48k, 50k, 56k, 56.6k, 64k, 72k, 76.8k, 115.2k (bit/s)
Error measurement pattern Pseudorandom pattern: PRBS 6, 7, 9, 11, 15, 19, 20, 23, RPRBS 20 (reversed PRBS20), QRSS, positive/negative logic
Programmable pattern: 8 bit repetitive (start-stop sync: 5 to 8 bits)
Code pattern: 1:1, ALL 1, ALL 0
User pattern: 1 to 1024 characters (1 character steps), for character error measurement
Send pattern User pattern: 1 to 128 kbyte
Error insertion Error type: bit, bit + code, code
Insertion types
Single: 1 bit error inserted each time insert button pressed
Repeat: 1 bit error inserted each second
Cyclic: 2.5E-1 to 1.7E-7
Start-stop synchronization Start bit length: 1 bit
Stop bit length: 1, 1.5, 2 bits
Data length: 5, 6, 7, 8 bits
Parity: None, odd, even
Error/alarm measurement Detected errors: Bit, code, parity, CRC, frame, character Measurements:
Error count, error rate, block error count, block error rate, ES, EFS, clock slip, clock slip seconds, pattern sync loss count/time, frame sync loss time, alarm time, signal loss time, AC power loss time
Error performance: G.821, G.826, M.2100
Measurement modes
Single: 1 s to 99 d 23 h 59 min 59 s
Repeat: 1 s to 99 d 23 h 59 min 59 s
Manual: 1 y max.
Measurement range
Error rate: 1.00E-15 to 1.00E00, Error count: 0 to 9.99E15
Pattern trace Trace byte count: 1 Mbit max.
Trace start trigger: Manual, code detect
Trace stop trigger: Manual, code detect, code mismatch detect, trace byte count
Trigger detect delay: 0 to 8,000 bytes
Frequency measurement Measurement range: DC to 10 MHz, Accuracy: =(±5 ppm ±1 digit)
Delay Time Measurement
(Sync. Mode Only)
Measurement range: 0 to 16 s (0.001 ms steps)
Frame relay measurement Measurement items: Correct test packet count, lost test packet count, HDLC bad frame count, HDLC abort frame count
PVC connect confirmation test: To MD6430A or circuit loopback test (Conforms to ITU-T Q.933 Annex A)
DLCI: 16 to 991 (1 steps)
Test packet send interval time: 5 to 30 s (1 s steps)
Traffic congestion status monitoring: BECN, FECN, CLLM message detection (Conforms to ITU-T Q.922 Annex A)
Digital level measurement Code law: A-law, µ-law
Measurement range: ?60 to +3 dBm (0.1 dBm steps)
Send pattern: 0 dBm, 1 kHz pattern (Conforms to ITU-T G.711)
ISDN calling/called function INS64, INS1500 (Option: MU643000A/B-01), Euro ISDN (Option: MU643000A/C-02)
MUX/DEMUX Able to drop/insert specified channels in high-speed interface through X.21 interface at 64k x n (n = 1 to 98)
Voice communication Voice communication possible in any TS in high-speed interfaces (except G.703 64 kbit/s)
Error analysis Displays sequential error/alarm measurement data and graphs
Signal monitor lamp Indicates status of each signal line
External printer Interface Centronics, D-sub 25-pin connector
External printer output Enables printout of error measurement data
Measurement start time: Prints time and measurement conditions
During measurement: Prints specified error and alarm occurrence at each detected instance or at predefined time interval
Measurement stop time: Prints measured total results
Prints on screen contents
Display Color TFT-LCD (8.4 size)
Remote interface RS-232C, D-sub 9-pin connector
Memory 3.5? FDD
Built-in timer Year, month, day, hour, minute, second
Power supply AC: 85 to 250 V, DC: Lithium ion battery (rechargeable, optional accessory), 50 VA
Battery operation time 3 h (max.) *5 h when using power save function
Operating temperature 0° to 50°C, (FDD and at battery usage: +5° to +40°C)
Dimensions and mass 290 (W) × 194 (H) × 94 (D) mm, =4.2 kg (excluding battery)
*1: Specification when using MU643000A Datacom Interface
*2: Specification when using MU643000B Datacom Interface
*3: Specification when using MU643000C Datacom Interface
*4: Max. n value depends on interfaces

MU643000C Datacom Interface Unit
 
Unit Interfaces Uses
MU643000C G.703 64k, I.430/I430-a 192k,
G.703/G.704/I.431 2.0M
Europe



For full Anritsu MD6430A product specifications, please click here: Anritsu MD6430A

Anritsu MD6430A Network Data Analyzer & MU643000C Datacom Interface Unit

The MU643000C has G.703 64k, I.430/I430-a 192k, G.703/G.704/I.431 2.0M European Datacom Interfaces

One unit supports installation and maintenance of leased lines, ISDN, and frame relay

Includes Carrying Case And Accessories As Listed 

MD6430 MD 6430A MU643000 6430 MD-6430

Anritsu MD6430A MU643000C MD-6430A MU-643000C Network Data Analyzer Models On Sale Warranty Calibration Backed by The Best Service and Lowest Prices in the Industry.

BC# 33763-L/T* 33764-L/T*

  • Anritsu MD6430A Network Data Analyzer (BC# 33763-L/T*) 
  • Anritsu MU643000C Datacom Interface Unit (BC# 33764-L/T*)
  • (2) BNC Cables
  • Protective Screen Cover
  • AC Adapter/Charger
  • Power Cord
  • RS232 PC Interface Cable
  • Strap For Unit
  • Carrying Case w/ Strap