Anritsu MW9070B MW0972A kit with accessories

Anritsu MW9070B SM Fiber Mini OTDR MW0972A

Anritsu MT9081D kit with accessories

Anritsu MT9081D SM ACCESS OTDR 1310nm 1550nm

Anritsu MT9083C Access Master SM Long Haul Fiber OTDR

$0.00
Availability: Out of stock
SKU
3K70

Condition: Refurbished / Calibrated

Warranty: 1 YEAR WARRANTY

Request a Quote for

Have Questions or doubts? Submit the following request and expect our detailed quote within 24 hours!

we are commited to win your business!

Anritsu MT9083C Access Master OTDR
Optical fibers are a key technology in today’s modern communications systems, including access networks such as FTTx, CATV, and optical LANs. Moreover, optical-fiber technologies are playing increasingly important roles in mobile communications and digital broadcasting systems. Technicians maintaining these diverse systems are forced to carry a large variety of test equipment on-site, including OTDRs, Light Sources, Optical Power Meters, Visible Light Sources, etc., as well as a notebook computer for evaluating the FTTx QoS. On the other hand, fiber construction requires measuring instruments with different functions and performance. As an example, FTTx access networks use single mode (SM) fiber whereas optical LANs use multimode (MM) fiber. In addition, core and backbone networks utilize long fibers while optical access networks use short fibers, both requiring different types of measuring instruments with different performance. But now Anritsu’s new line of MT9083 ACCESS Master OTDRs solves all these problems by providing all the measurement functions and performance required for optical fiber construction and maintenance in a compact, lightweight, all-in-one unit that eliminates the burden of carrying many different test sets and instruments on-site. Whatever your work, construction or maintenance, long haul or intra-building, Anritsu has an MT9083 model for your needs.

Designed with the Features that Matter Most
When buying products, you tend to choose ones that are innovative and from established companies. When you need to install and maintain optical networks, this should also apply. With over 50 years of combined OTDR design, Anritsu, delivers the features that matter. Having been in the test and measurement business for a long time, we understand that things like performance, portability, reliability, easy operation and of course price are important.

Quick Startup
The ACCESS Master is ready for measurement about 15 seconds after power-on so productive work can start immediately.

Long Battery Life
Since AC power is not always available where you need it, especially at fiber pedestals, the MT9083 typically provides up to 8 hours of operation on a single charge. This coupled with an optional car cord (for cigarette lighter operation) guarantees the MT9083 is ready when you are.

Portable
With its light weight design and user friendly dimensions, the MT9083 is perfect for the outside plant environment and can easily be managed with one hand. The shoulder strap (part of the protector option) further increases portability when travelling from the truck to the testing site.

Rugged
The MT9083 features a solid casework with no fans or vents to keep dust or moisture from entering the unit.In addition, the protector option (MT9083A/B/C-010) includes rubber bumpers and a display cover for additional protection from those minor mishaps.

Generous Data Storage
With the ability to store up to 1,000 traces in internal memory and up to 30,000 via a USB device, the MT9083 offers plenty of storage for collecting and managing data.

No Experience Required
With the ACCESS Master, the experience is built in. With specialized testing modes, automatic parameter selection, PASS/FAIL indicators as well as features to virtually eliminate the chance to get “bad” results, the MT9083 can make anyone seems like a 20 year veteran. Let it help you master your network.

Easy "drag and drop" File Transfers
When the MT9083 is connected to a PC via a USB cable, the internal memory of the ACCESS Master can be directly accessed. Data can be selected, dragged and dropped into the PC memory, greatly simplifying file transfers. The MT9083 also supports use of USB memory sticks.

Common OTDR Data Format
The MT9083 supports the universal Telcordia SR-4731 (issue 2) format making it compatible with not only legacy Anritsu and NetTest products, but with many other vendors data.

Free and Simple Software Upgrades
Firmware upgrades are easily performed via USB and available from the Anritsu website for registered users or through Anritsu customer support.

Active fiber check
Not only can OTDR measurements be effected when the optical fiber is in-service but there is a potential risk of damage to the transmitter and OTDR receiver. To prevent these problems, the MT9083 verifies if light is present before starting measurement and will not transmit if it is. An on-screen warning and internal OTDR protection are also part of this useful feature.

Integrated Macrobend Detection
With many technicians making the switch from copper installations to optical fiber, installation issues such as macrobends are bound to occur. To help prevent this, Anritsu has developed a macrobend detection feature for the MT9083 that will alert technicians when a possible macrobend is present. This provides a higher quality of service for the customer and eliminates costly troubleshooting for you.

Wavelengths for Today's Networks
Sometimes you just need more than the traditional 1310 and 1550 nm wavelengths to certify your next generation networks. The MT9083 offers a host of specialized wavelengths including 1383 nm for water peak verification of CWDM carrying fibers, 1650 nm (with integrated filter) for live fiber troubleshooting, 1490 nm for verification of voice, data and IP based video services and 780 nm for in-service troubleshooting of FTTx networks - without the need for any additional filters.

All-in-one Test Set
The MT9083 delivers full featured OTDR performance plus loss test set and quality of service measurement in a surprisingly small and lightweight package. At only 28.4 cm wide × 20 cm tall × 7.7 cm deep and 2.2 kg (4.8 lbs.), it is field portable, yet rugged enough to withstand the outside plant environment. When equipped with power meter, visual light source and IP test options, it replaces several, larger pieces of test equipment.

Features:
  • Ready to test in about 15 seconds…and all day without recharging
  • Specialized testing modes simplify operation
  • High resolution and high dynamic range ensure quick and through fiber evaluation
  • Intelligent analysis software identifies problem splices, connectors and even macrobends
  • Rugged, sealed design provides years of service in the most challenging environments
  • Test up to four wavelengths with a single unit - single mode, multimode or both
  • Unique in-service testing without the need for external filters
  • Verify connector quality with optional connector inspection microscope

Specifications:
Dimensions and Mass Size: 270 (W) × 165 (H) × 61 (D) mm 10.6 × 6.5 × 2.4 inches
Weight: 2.2 kg (4.8 lbs) including battery
Display 6.5 inch TFT-LCD (640 × 480, with backlight, transparent type), enhanced indoor/outdoor optional
Interface USB 1.1, TypeA × 1 (memory), Type B × 1 (USB mass storage)
Data Storage Internal memory: 440 MB (up to 1000 traces),
External memory (USB): up to 30,000 traces with 512 MB
Power Supply 12 VDC,
100 to 240 VAC, Allowable input voltage range: 90 to 264 V, 50/60 Hz
Battery Type: Lithium ion Operating Time∗1: 8 hours Recharge Time: <5 hours (power off)
Power saving functions Backlight off: Disable/1 to 99 minutes Auto shutdown: Disable/1 to 99 minutes
Vertical Scale 0.13, 0.33, 0.65, 1.3, 3.25, 6.5, 13 dB/div
IOR setting 1.400000 to 1.699999 (0.000001 steps)
Units km, m, kft, ft, mi
Languages User selectable (English, Simplified Chinese, Traditional Chinese, French, German, Italian, Korean, Portuguese, Russian, Spanish and Swedish - contact Anritsu for availability of others)
Sampling Points Normal: 5001, High density: 20001 or 25001 (MT9083A and B series), up to 150,001 (MT9083C series)
Sampling Resolution 5 cm (min.)
Reflectance Accuracy Single mode: ±2 dB, multimode: ±4 dB
Distance Accuracy ±1 m ±3 × measurement distance × 10-5 ± marker resolution (excluding IOR uncertainty)
Distance Range Single mode: 0.5, 1, 2.5, 5, 10, 25, 50, 100, 200 km (MT9083A and B series, except 780 nm: 0.5, 1, 2.5 km) 0.5, 1, 2.5, 5, 10, 25, 50, 100, 200, 300 km (MT9083C series) Multimode: 0.5, 1, 2.5, 5, 10, 25, 50, 100 km
Testing Modes Fault locate: Provides end/break location, end to end loss, fiber length
Standard OTDR: User selectable automatic or manual set-up
Construction OTDR: Automated, multi-wavelength testing
Light source: Stabilized Light source (CW, 270 Hz, 1 kHz, 2 kHz output)
Connector Video Inspection Probe
Fiber Event Analysis Auto or manual operation, displayed in table format
User defined PASS/FAIL thresholds:
- Reflective and non-reflective events: 0.01 to 9.99 dB (0.01 dB steps)
- Reflectance: –70.0 to –20.0 dB (0.1 dB steps)
- Fiber end/break: 1 to 99 dB (1 dB steps)
Number of detected events: up to 99 Macrobend detection
OTDR Trace Format Telcordia universal. SOR, issue 2 (SR-4731)
Other Functions Real time sweep∗4: 0.15 sec.
Loss modes: 2 point loss, dB/km, 2 point LSA, splice loss, ORL
Averaging modes: Timed (1 to 3600 sec.)
Live Fiber detect : Verifies presence of communication light in optical fiber
Connection check: Automatic check of OTDR to FUT connection quality
Trace overlay and comparison, Template function, USB keyboard support, Remote control, Video output to PC
Environmental Conditions Operating temperature and humidity: 0° to +40°C (MT9083A and B series), <80% (non-condensing)
0° to +45°C (MT9083C series), <80% (non-condensing)
Storage temperature and humidity: –20° to +60°C, <80% (non-condensing)
Vibration: Conforming to MIL-T-28800E Class 3
Dust proof: MIL-T-28800E Class 2
Drip proof: IP51 (IEC 60529), JIS C 0920 TYPE I
EMC EN61326-1, EN61000-3-2
LVD EN61010-1
OTDR Specifications
Wavelength 1310/1550 nm ±25 nm
Fiber Type Single Mode (SMF) 10/125 µm ITU-T G.652
Pulse width 3, 10, 20, 50, 100, 200, 500, 1000, 2000, 4000, 10000, 20000 ns
Dynamic Range 45/45 dB
Deadzone (Fresnel) ≤1 m, ≤0.8 m (typ.)
Deadzone (Backscatter) ≤3.8/4.3 m




For full Anritsu MT9083C product specifications, please click here: Anritsu MT9083C

Anritsu MT9083C SM 1310/1550nm Long Haul Access Master OTDR Mainframe w/ Power Meter & VFL

Dynamic Range:
1310 / 1550 nm : 45 / 45 dB

Power Meter:
- 1310nm
- 1383nm
- 1490nm
- 1550nm
- 1625nm
- 1650nm

Includes Carrying Case & Accessories As Listed 

MT-9083C  MT 9083C

Anritsu MT9083C Access Master MT-9083C OTDR Models On Sale Warranty Calibration Backed by The Best Service and Lowest Prices in the Industry.

BC# 34097

  • Anritsu MT9083C Access Master SM Long Haul OTDR (BC# 34097)
    • SM OTDR Source:
      • 1310nm
      • 1550nm
    • SC Connector For Source
    • Power Meter:
      • 1310nm
      • 1383nm
      • 1490nm
      • 1550nm
      • 1625nm
      • 1650nm
    • SC Connector For Power Meter
    • Visual Fault Locator
  • (2) SM SC-SC Fiber Cables
  • (4) Fiber Wipes
  • Battery Pack
  • AC Adapter/Charger
  • Power Cord
  • USB PC Interface Cable
  • User Manual On CD-ROM
  • Carrying Case (G)