Anritsu Site Master S332E Cable & Antenna Analyzer

Anritsu Site Master S332E Cable & Antenna Analyzer

Anritsu S820C Cable Antenna Analyzer 3.3 to 20 GHz

Anritsu S820C Cable Antenna Analyzer 3.3 to 20 GHz

Anritsu SiteMaster S820D Broadband Cable & Antenna

$0.00
Availability: Out of stock
SKU
6C164

Condition: Refurbished / Calibrated

Warranty: 1 YEAR WARRANTY

Request a Quote for

Have Questions or doubts? Submit the following request and expect our detailed quote within 24 hours!

we are commited to win your business!

Anritsu's handheld, battery operated Broadband Site Master is the most accurate and convenient tool available for field installation, verification, troubleshooting and repair of microwave cables and communication systems. With calibrated vector error correction and a convenient user interface, difficult test specifications become easy to verify, quality is improved, and maintenance expenses are reduced.

The Broadband Site Master targets microwave site installers, point-to-point operators, point-to-multipoint operators, radio manufacturers, private/public networks that support microwave links, and defense programs responsible for the installation and maintenance of microwave cables. The Broadband Site Master models test both waveguide and coaxial cables more conveniently than laboratory sized scalar analyzers or microwave test sets.

Enhanced Performance and Functionality
The Broadband Site Master offers the following improvements over the preceding model:

  • Increased frequency range to cover 25 MHz to 20 GHz with a single connection
  • Updated thin film transistor (TFT) color display that is easily viewable in direct sunlight
  • Increased measurement speed so screen updates occur in real time
  • Faster distance-to-fault (DTF) calculations allow real time updates
  • Added GPS functionality enables data to be stored with latitude, longitude, and altitude information

Cost Savings and Quality Improvement
Market competition requires operators to reduce per site maintenance expenses. Site Master's Frequency Domain Reflectometry (FDR) technique breaks away from the traditional fix-after-failure maintenance process by finding small, hard to identify problems before major failures occur.

Sixty to eighty percent of a typical cell site's problems are caused by problematic cables, connectors and antennas. Cables installed in aircraft and on-board ships are difficult to troubleshoot and can cause extensive down time. When cables are damaged, mis-positioned, or contaminated with moisture, Site Master identifies the problem quickly. Antenna degradation reduces the cell coverage pattern. Site Master can pinpoint the antenna problem from ground level in a few seconds so climbing the antenna tower becomes unnecessary.

FDR Technique
Frequency Domain Reflectometry (FDR) and Time Domain Reflectometry (TDR) have similar acronyms, and both techniques are used to test transmission lines. But that's where the similarities end. The TDR technique is not sensitive to RF problems. The TDR stimulus is a DC pulse, not RF. Thus, TDR is unable to detect system faults that often lead to system failures. Additionally, the FDR technique saves costly, time-consuming trouble shooting efforts by testing cable feedline and antenna systems at their proper operating frequency. Deficient connectors, lightning arrestors, cables, jumpers, or antennas are replaced before call quality is compromised.

Insightful and Convenient Measurements

Site Master performs various RF measurements aimed at simplifying transmission line and antenna system analysis: Return Loss, SWR, Cable Loss, and Distance-to-Fault (DTF). A single soft key selection on the main menu activates the desired measurement mode.

Return Loss, SWR
Return Loss and SWR measurements ensure conformance to system performance specifications. The measurement can easily be toggled between either one of the two modes and can be performed without climbing the tower.

Cable Loss
Cable Loss measurements determine the level of insertion loss within the cable feedline system. Insertion loss can be verified prior to deployment, when you have access to both ends of the cable, or on installed cables without access to the opposite end.

Distance-to-Fault
Although a Return Loss test can tell users the magnitude of signal reflections, it cannot tell the precise location of a fault within the cable system. A Distance-to-Fault measurement provides the clearest indication of trouble areas as it gives both the magnitude of signal reflection and the location of the signal anomaly.

Vector Error Correction
Vector error correction within the S8x0 ?D? Series improves the quality and convenience of measurements compared to traditional scalar techniques. Accuracy and repeatability are enhanced as errors such as test port match and source match are removed.

Waveguide Dispersion and Calibration
Vector error correction using FDR improves the quality of Distance-to-Fault data. Not only is the reflection magnitude more accurate, but the waveguide dispersion correction for fault location (different frequencies propagate at different speeds) is more accurate and repeatable. Unlike scalar-based systems, the Broadband Site Master S8x0 ?D? Series does not suffer reflection magnitude errors and length inaccuracies in proportion to the relative lengths of the coaxial input cable and waveguide under test.

Coaxial Connections
Site Master supports frequently used coaxial connectors such as K, N, and TNC.

Specifications

Frequency Range 25 MHz to 20000 MHz
Frequency Accuracy (CW mode) =3 ppm at +25ºC
Frequency Resolution 10 kHz
Output Power <0 dBm
Immunity to Interfering Signals on-channel +13 dBm
on-frequency ?10 dBm
Measurement speed Return Loss, SWR, DTF =2 sec/sweep for 517 data points (CW ON)
=4 sec/sweep for 517 data points (CW OFF)
Number of data points 130, 259, 517
Return Loss Range 0.00 to 60.00 dB
Resolution 0.01 dB
VSWR Range 1.00 to 65.53
Resolution 0.01
Coax/Waveguide Insertion Loss Range 0.00 to 30.00 dB
Resolution 0.01 dB
Measurement Accuracy =42 dB corrected directivity after calibration for <5 GHz
=36 dB corrected directivity after calibration for <15 GHz
=32 dB corrected directivity after calibration for >15 GHz
Test Port Connector Precision K(f) or N(f) (Option 11NF)





For full Anritsu SIte Master S820D product specifications, please click here: Anritsu Site Master S820D

Anritsu Site Master S820D Broadband Cable & Antenna Analyzer w/ Option 5: Power Meter

25 MHz to 20 GHz Frequency Range

Includes Anritsu Open/Short/Load, Carrying Case & Accessories As Listed 

Anritsu S820D S-820D SiteMaster Broadband Cable Antenna Analyzer Models On Sale Warranty Calibration Backed by The Best Service and Lowest Prices in the Industry.

BC# 32177 17356M

  • Anritsu SiteMaster S820D Broadband Cable & Antenna Analyzer w/ Option:(BC# 32177)
    • Option 5: Power Meter
  • Anritsu 22K50 Open/Short
  • Anritsu 28K50 Termination
  • Anritsu Detector 560-7K50
  • Anritsu 15KKF50 - 1.5A Test Port Cable
  • Anritsu 26UA137 Low Power Termination
  • Anritsu 26UA90 Low Power Termination
  • Anritsu 35UA137N Coax Adapter
  • Anritsu 24UA137 3/8 Offset Short
  • Anritsu 23UA137D 1/8 Offset Short
  • DC Car Charger
  • Anritsu 23UM100 Offset Short
  • Anritsu 24UA90 3/8 Offset Short
  • Anritsu 90AC206 NB WG To Coaxial Adapter
  • BNC Cable
  • AC Adapter/Charger
  • Power Cord
  • RS232 PC Interface Cable
  • Hard Copy User Manual
  • Carrying Case