| Fiber requirements |
Single- and multimode silica glass fibers with cladding
diameter of 25 µm and coating diameter of 250 µm to 900 µm |
| Fiber clamping |
On bare 125-µm fiber |
| Splice loss (for identical fibers with low core
eccentricity) |
• Standard single-mode fibers: typically less 0.05 dB •
Multimode fibers: typically less 0.02 dB
|
| Splicing process |
fully automatic or manual (selectable) |
| Splice process control |
Alignment and fusion performed by video image
evaluation |
| Fiber alignment |
Alignment in z-direction with stage motors |
| Splice analysis |
Splice loss estimation tensile test 2.2 N
nominal |
| Fiber endface evaluation |
Endface quality inspection, contamination detection |
| Fiber display |
4-inch color monitor, magnicication: 25x and 100x |
| Splice time |
typically 10 sec. incl. alignment fusion and analysis |
| Operating range |
Operating temp.: -5°C to +45°C; Relative humidity: <
95 %; Storage temp.: -40°C to +60°C |
| Dimensions (L x B x H) |
Splicer: 254 x 242 x 178 mm
|
| Weight |
Splicer without accessories: 3.5
kg; |