Corning 340M-57 top down

Corning 340M-57 SM MM Fiber OTDR Module

EXFO FTB-400 FTB-7323B FTB-8510 Kit with accessories

EXFO FTB-400 FTB-7323B SM Fiber OTDR w/ FTB-8510

EXFO FTB-400 FTB-7300D SM Fiber OTDR w/ FTB-PSB

$0.00
Availability: Out of stock
SKU
3F118

Condition: Refurbished / Calibrated

Warranty: 90 Day Exchange

Request a Quote for

Have Questions or doubts? Submit the following request and expect our detailed quote within 24 hours!

we are commited to win your business!

The FTB-400 Universal Test System (UTS) provides a simple, yet efficient,way to perform multiple advanced test operations in outside plant installation,maintenance, and troubleshooting.

If you're looking for high efficiency, the FTB-400 Universal Test System is the answer. Benefit from advanced test operations in outside plant installation, maintenance and troubleshooting. Evolve with the latest technologies. From power readings and OTDR testing to optical switching, CD and PMD analysis, DWDM testing, protocol, datacom and data post-processingラthe FTB-400 Universal Test System does it all. More importantly, the FTB line of swappable test modules continues to expand with new test applications and accelerated test routines. The powerful FTB-400 can perform simultaneous acquisitions and data post-processing.

The ultimate platform for network experts

  • Simultaneous acquisitions and fast data post-processing
  • Scalable range of test applications and field-interchangeable modules
  • Pentium-powered Windows operating system
  • Easy-to-read, high-resolution 30.7 cm transflective (TFT) screen

Combining physical, optical, transport and datacom testing in a single box

  • Physical and optical testing: complete fiber and signal characterization using OTDR, OLTS, PMD, CD and OSA test modules
    Transport and datacom testing: QoS assurance validation using SONET/SDH and Ethernet test modules

Powerful

  • Power management is a snap, thanks to the ToolBox software. EXFOメs FTB-400 is based on the Windows® 2000 operating system, run by a Pentium-series processor with up 512 MB of SDRAM
    • Fast, intuitive Sleep mode for power conservation
    • Far-ranging operating time
    • Automated power management

Rapid

  • Get moving faster, get results faster. New-generation processing power means acquisitions and data analysis are quicker than ever. And enjoy the advantage of EXFO's exclusive online data post-processing.
    • Quick, easy data transfer
    • Extremely fast acquisitions
    • Efficient data post-processing
    • Two USB ports
    • Infrared (IrDA) port
    • PCMCIA type III
    • Writable CD-ROM

SPECIFICATIONS

  • Display:
    • Touchscreen, color, 800 x 600 TFT 307 mm (12 1/16 in)
  • Interfaces
    • Serial RS-232
    • Parallel port
    • External monitor
    • Two USB 1.1 ports
    • Infrared (IrDA) port
    • Audio microphone In 3.5 mm
    • Audio speaker Out 3.5 mm
    • Two PCMCIA type II or one PCAMCIA type III
  • Storage
    • Internal 40 GB hard drive minimum (over 750 000 OTDR test files)
    • Internal 3.5 in 1.44 MB floppy drive
    • External USB read/write CD-ROM (optional)
    • Flash memory cards (256, 512, 1024 MB) (optional)
    • NTFS file system
  • Batteries
    • Rechargeable NiMH battery pack (two batteries for two-slot receptacle, two for four-slot receptacle, four for seven-slot receptacle, two for eight-slot receptacle) > 8 h of continuous operation as per Bellcore TR-NWT-001138
  • Power supply
    • 100ヨ240 VAC, 50/60 Hz and 12ヨ24 VDC for the two-slot (GP-402) and the seven-slot (GP-407) module receptacles; 100ヨ240 VAC, 50/60 Hz and 24 VDC for the four-slot (GP-404) module receptacle; and 100-240 VAC, 50/60 Hz for the eight-slot
      (GP-408) module receptacle GENERAL SPECIFICATIONS
  • Temperature
    • operating: 0 ºC to 50 ºC (32 ºF to 122 ºF)
    • storage: ヨ40 ºC to 60 ºC (ヨ40 ºF to 140ºF)
  • Relative humidity
    • 0 % to 95 % (non-condensing)

  • Size (H x W x D)
    • Mainframe + eight-slot module receptacle: 318 mm x 343 mm x 246 mm
      (12 1/2 in x 13 1/2 in x 9 11/16 in)

  • Weight
    • Mainframe + eight-slot module receptacle, including two NiMH batteries: 11.1 kg (24.5 lb)

  • Vibration:
    • < 1.5 g. at 10 Hz to 500 Hz (on three main axes)

  • Mechanical shock:
    • e < 760 mm on six sides and eight main edges (according to GR-196-CORE)

  • Isolation:
    • Spillproof and splashproof

  • CE compliance:
    • Class A certification

Specifications:

FTB-7300D SM

Short Dead Zones

EXFO's FTB-7200D and FTB-7300D OTDRs help you boost test productivity for inside-plant applications. Their exceptional 1 m event dead zone enables you to easily locate and characterize all events between the transmitter and the central office's fiber distribution panel. This feature also comes in handy in metro, access and FTTH network applications, where events are usually closely spaced.

Multimode and Singlemode Flexibility

The FTB-7200D model combines singlemode and multimode functionalities, ideal for private/premises/enterprise network testing. It offers the industry's shortest dead zones, as well as lightning-fast acquisitions. Test multimode fiber within premises, or singlemode fiber between premisesラall with a single OTDR unitラand maximize your return on investment.

Optimizing Passive Optical Network (PON) Testing

Designed to meet the testing requirements brought by FTTH networks in general, and PONs in particular, the FTB-7300D enables testing at 1310, 1490 and 1550 nm. What's more, EXFO's next-generation OTDR software lets you test through high-port-count splittersラeven 1x32 splittersラwith loss levels of up to18 dB.

Delivering Higher Accuracy for Event Location

The FTB-7200D and FTB-7300D OTDRs locate events with pinpoint accuracy:

  • Up to 128 000 sampling points for higher trace resolution
  • Sampling resolution down to 4 cm, for ultra-accurate fault location
  • Better linearityラdown to ±0.03 dB/dBラfor more accurate event characterization

Technical Specifications:

Parameter Specification
Wavelength i (nm) 1310 ± 20/1550 ± 20
Dynamic range at 20 µs j (dB) 39/37
Event dead zone k (m) 1/1
Attenuation dead zone k (m) 4.5/5
Distance range (km) 1.25, 2.5, 5, 10, 20, 40, 80, 160, 260
Pulse width (ns) 5, 10, 30, 100, 275, 1000, 2500, 10 000, 20 000
Linearity (dB/dB) ±0.03
Loss threshold (dB) 0.01
Loss resolution (dB) 0.001
Sampling resolution (m) 0.04 to 5
Sampling points Up to 128 000
Distance uncertainty n (m) ± (0.75 + 0.0025 % x distance + sampling resolution)
Measurement time User-defined (60 min maximum)
Typical real-time refresh (Hz) 3
Stable source output power o (dBm) ヨ7 (7200D), ヨ3.5 (7300D)
Visual fault locator (optional) Laser, 650 nm ± 10 nm
CW, typical Pout in 62.5/125 µm: 3 dBm (2 mW)

EXFO Pulse Suppressor Box

An OTDR testing essential

Combined with EXFO OTDR equipment, the Pulse Suppressor Box (PSB) enables loss measurement on the first and last connections of the fiber under test.

Choice of configurations
Typically, dead zones are about the same length as the optical pulse plus a few meters. So the Pulse Suppressor Box configuration should be longer than the pulse selected for the test session. The PSB is available in lengths of 300 m, 500 m and 1500 m, with a choice of singlemode or multimode fiber. EXFO also offers a wide range of connectors for quick connection to most OTDR and patch panel ports. The PSB is housed in a compact, field-proof case for maximum protection.

How it works
Often, the longest dead zone occurs at the first connection (the OTDR bulkhead connector). Because it is impossible to measure loss within a dead zone, loss due to splices and connectors close to the OTDR launch point cannot be determined under ordinary circumstances. However, you can work around this problem by connecting the Pulse Suppressor Box between the OTDR and the fiber under test. The length of fiber in the PSB distances the dead zone from the splices and connectors to be checked, and these crucial loss values can then be measured.

Loss from the last connector of the fiber under test can be measured in the same way, by placing the extra fiber length of the PSB after the connector. This extra fiber enables the OTDR to compare backscatter levels before and after the event to calculate the connector loss.

Features:

  • Rugged and compact case
  • Metal lid support prevents lid from falling and damaging patchcords

Specifications:

 
Size (H x W x D) 20 cm x 15 cm x 10 cm (8 in x 6 in x 4 in)
Weight < 2.5 kg (< 5.5 lb)
External patchcord length 2 x 3 m (2 x 10 ft)
Multimode fiber 50/125 µm
Attenuation Range:
850 nm 2.4 to 3.0 dB/km
1300 nm 0.6 to 1.2 dB/km

 

EXFO FTB-400 MINI-OTDR Fiber Mainframe w/
FTB-7300D-023B-EI Singlemode 1310 / 1550nm OTDR Module
&
FTB-PSB Pulse Suppressor Box Module

Dynamic Range:
1310 / 1550 nm : 39 / 37 dB

Combined with EXFO OTDR equipment, the Pulse Suppressor Box (PSB) enables loss measurement on the first and last connections of the fiber under test

Includes Carrying Case & Accessories As Listed

FTB-7300D FTB 7300D 400 FTB 400 FTB7300D PSB

EXFO FTB-400 FTB-7300D FTB-PSB FTB400 FTB7300D FTBPSB OTDR Models On Sale Warranty Calibration Backed by The Best Service and Lowest Prices in the Industry.

BC# 22043 22205 22207

  • EXFO FTB-400 OTDR Main Frame (BC# 22043)
  • EXFO FTB-7300D-023B-EI SingleMode OTDR Module (BC# 22207)
    • SM OTDR Source:
      • 1310nm
      • 1550nm
  • EXFO FTB-PSB Pulse Suppressor Box Module (BC# 22205)
  • Ethernet Cable
  • (2) SM SC-SC Fiber Cables
  • Stylus
  • (4) Fiber Wipes
  • AC Adapter/Charger
  • Power Cord
  • RS232 PC Interface Cable
  • User Manual On CD-ROM
  • Carrying Case (G)