Dual-wavelength Fiber SmartProbes allow the WireScope™ Pro to measure length
and propagation delay on optical fiber links. Also, they enable high-performance
optical loss and power measurement.
| Part Numbers |
Description |
| Power Meter Detector Type Calibrated Wavelengths
Measurement Accuracy Power Measurement Range |
InGaAs 1310 nm, 1550 nm ±0.25 dB at –20 dBm 0 to
–50 dBm |
| Transmitter Source Type Center Wavelength Output
Power Laser Stability |
Fabry-Perot Laser 1310 nm ± 30 nm, 1550 nm ± 30 nm
= –6 dBm (into 9/125 µm fiber) ±0.1 dB (1 hour, after 5 minutes
warm-up) |
| Fiber Network Specifications Cabling Standards
Ethernet Legacy Networks ATM/SONET FDDI/Fiber Channel |
ANSI/EIA/TIA 568A, 568.3, ISO/IEC 11801
10GBASE-LR, -LW, -ER, -EW, -LX4 1000BASE-LX, -LX10 100BASE-LX10 ATM-622,
ATM/SONET OC-3, OC-12, OC-48 FDDI |
| Propagation Delay Accuracy (whichever is greater)
Resolution Measurement Range |
±2% or ±3.6 ns 4.2 ns 0 to 300 µs |
| Fiber Length Accuracy (whichever is greater)
Resolution Distance Range |
±2% or ±0.72 m 0.83 m at Refractive Index 1.4785 0
to 50 km for 1.50 dB/km at 1310 nm |
|