The Fluke 125 Industrial ScopeMeter is a rugged, reliable solution for
industrial troubleshooting and installation applications. Integrated test
tool, with oscilloscope, multimeter, and “paperless” recorder in one affordable,
easy-to-use instrument.
As the latest addition to the Fluke 120 Series
ScopeMeters, the Fluke 125 has advanced features for installing and
troubleshooting field buses and electrical machines. The ScopeMeter performs a
bus health test on industrial buses, for example, which are rapidly becoming a
headache for Service, Maintenance and Installation (SMI) engineers. The test
quickly determines whether the bus is working and if not, helps to identify the
cause. The rugged ScopeMeter works with many Industrial Networks including AS-I
bus, CAN-bus, Profibus, Foundation Fieldbus and Ethernet.
In addition,
the instrument can test power input, sensor timing, motor windings, drive output
timing and power measurements – thus eliminating the need for expensive, more
specialized test equipment.
The ScopeMeters are 600 V CAT III safety
certified for machinery, instrumentation, control and power systems. The new
Fluke 125 has all the features of the successful Fluke 123 and Fluke 124
ScopeMeters and, in addition to the bus health test, it also carries out
effective (Vpwm) voltage measurements of motor drive output, and has 0.01 ohm
resolution on the 50 Ohms range for testing motor windings. User-named data
setups make for easy use. The 125 extends the 120 series by adding;
Industrial networks bus health testing and Measure harmonics and power, VA, VAR,
W, and PF
Simple good/bad readout for Field Bus parameters The bus
health tests of the Fluke 125 ScopeMeter find defects like bad or missing
terminators, bad cable splits, missing links, incorrect line loading, line
interrupts, short circuit conditions and reflections. The instrument
continuously acquires the bus signal and compares parameters to official
specifications. It displays bus speed and measures signal quality with ‘good’ or
‘bad’ indications for parameters like rise- and fall-time, amplitude, bias
level, pulse width and distortion. The instrument checks at the hardware (not
protocol) level. An eye-pattern mode allows for a visual check of signal
integrity.
Harmonic analysis and power consumption Extended Harmonics
Analysis of mains waveforms reaches up to the 33rd harmonic. That includes the
important 3rd and 5th harmonics, which may be the cause of overheating in
neutral wire or motor, as well as flat-topping of the mains voltage from
non-linear loads like SMPS units. The wide frequency range covers railway (16.66
Hz) and airplane systems (400 Hz) applications.
Power measurements cover
single-phase and balanced-3-phase, 3-wire systems (Watt, VA, VAR and Power
Factor). Unlike PQ analyzers, the instrument is not restricted to 50/60 Hz, and
can measure power at the output of motor drives and frequency
converters.
The Vpwm measurement capability shows the output voltage of
motor drives exactly as the motor perceives it. For electrical and combustion
engines, the 125 can indicate revolutions-per-minute (rpm), and can be set up
for 1 or 2 rotations per pulse, or 1 rotation per 2 or 4 pulses. A 50-ohm
resistance range brings excellent 0.01-ohm resolution for checking motor
windings and other wiring.
Series automates measurements from industrial
systems The Fluke ScopeMeter 120 Series performs automated measurements on
motor, switch and similar signals. The 123 has a 20 MHz bandwidth, while the 124
is a 40 MHz bandwidth instrument that performs more advanced measurements. The
125 is also a 40 MHz instrument but includes features for testing Field Bus and
motors. All incorporate Fluke’s unique Connect-and-View to recognize signal
patterns, and automatically set up correct triggering.
Features
- Industrial Network Bus Health mode
- Power Measurements for single phase and balanced 3-phase systems
- Harmonics mode, up to 33rd harmonic
- High resolution, low impedance measurements
- Reading of Hz and Rotations Per Minute (RPM) for use with electrical and
combustion engines
- Measurement of Vpwm for use on motor drive outputs
- ‘Save and recall’ using a user-defined name
- Fluke i400s Current Clamp included as a standard
Bus Health
mode allows for an analysis of the signal quality on industrial network,
comparing measured signals to the standards’ signal requirements. Fluke
125 is the ScopeMeter of choice for the maintenance engineer who deals with
industrial machinery and the industrial network connecting his machinery the
like. The Fluke 125 has all the functionality of the 124 plus it comes with the
following extensions:
- Bus Health mode gives a clear “Good” / “Bad” indication for the electrical
signals on industrial buses and networks, such as CAN-bus, Profi-bus, RS-232
and many more. The Fluke 125 validates the quality of the electrical signals
as soon as any electrical signals are passed along the network. It checks the
signal levels and speed, transition times and distortion, and compares these
to the appropriate standards to help you find errors like improper cable
connections and terminators. It helps you find the source of error in case
communication comes to a halt. All the commonly found industrial network types
are supported!
- Power Measurements for single phase and balanced 3-phase systems. The
Fluke 125 can directly present you the Total Power (Watts), Apparent Power
(VA), Reactive Power (VAR) and the Power Factor (PF), over a wide range of
applied frequencies, including those seen with motor drives and inverters. As
a result, you are able to easily see the effects on the various power
measurements during start-up or under changing operational conditions. A
current clamp is included as a standard.
- Harmonics mode graphically displays harmonics up to the 33rd harmonic to
assist in fault-finding, e.g. with large non-linear loads.
- RPM and Hz reading for use with electrical and combustion engines.
- Vac pwm for use on motor drive outputs, reading the true output voltage
experienced by the motor itself.
- Low impedance measurements giving a 0.01 ohms resolution for motor
windings and the like.
Specifications |
| Oscilloscope Bandwidth |
|
| Dual input True RMS Meter |
|
Vdc, Vac, Vac+Vdc, Ohms,Continuity ,
Diode-test |
|
Current, °C, °F, Capacitance, dBV, dBM,
Crest Factor, Touch Hold and Zeroset | |
| TrendPlot Recording |
|
Automatic vertical scaling and time
compression. |
|
Display the actual, MIN, MAX and AVG
reading. | |
| Cursors |
| ?T, 1/?T, V, ?V, rise- and fall
time | |
| Real-time sample rate |
|
| Inputs and digitizers |
|
| Timebase range |
|
| Input sensitivity |
|
| Trigger types |
|
Connect-and-View™, Free Run, Single Shot,
Edge, Video, External | |
| Glitch capture |
|
| Scope measurements |
|
| Maximum record length |
|
512 min/max pts per
input | |
| Memory |
|
Environmental Specifications |
| Operating Temperature |
|
| Storage Temperature |
|
| Operating Altitude |
|
Safety Specifications |
| Electrical Safety |
|
Mechanical & General Specifications |
| Size |
|
| Weight |
|
| Battery Life |
|
| RS-232 Interface |
|
Optically isolated via optional PM9080 or
OC4USB for interfacing to Printer or
PC | |
|