Fluke 225C – Color ScopeMeter with Industrial Bus Health Test capability
Based on the 199C and 196C Color ScopeMeters, the 225C offers the full
functionality of those instruments yet with the addition of powerful test
capabilities for a wide variety of Industrial Bus systems. When in Bus health
Test mode, these ScopeMeters automatically make an analysis of the
electrical signals passing through the bus, and compare the parameters to
standard values as described in the industry standards for that bus type.
Alternatively, the user may select an ‘Eyepattern’ display to visually check the
overall signal quality.
Parameters are automatically qualified as ‘good’, ‘weak’ or ‘bad’ based on a
comparison to the appropriate industrial standards or to user set reference
values. Each of the measured parameters is presented with momentary value and
with statistical minimum and maximum values measured over time. The reference
values used are also displayed, to give the user an easier grip on the systems
behaviour. Tested parameters include signal amplitudes, bias voltage, rise- and
fall-times, jitter, distortion and noise levels (in-band noise as well as
out-of-band noise) depending on the requirements of the associated industry
standard.
Features
The Fluke 225C and 215C are the instruments of choice for maintenance
specialists who deal with industrial buses and networks as well as with general
electronics. You can verify the electrical integrity of your bus and network,
performing ‘physical layer tests’ and getting answers quickly and easily.
Based on the 200 MHz or 100 MHz 190C Series Color ScopeMeters, these
instruments offer all functions found in the 190C Series, with Bus Health Test
capabilities added on top.
Bus Health Test Bus
Health Test analyses the electrical signals on the industrial bus or network and
gives a clear “Good, “Weak or “Bad validation mark for each of the relevant
parameters, presented next to the actual measurement value. Measured values are
compared to standard values based on the selected bus type, or you may set your
personal reference values if you need different tolerances.
Automatic analysis and validation of electrical signal parameters
All common bus types are supported The 225C and 215C
ScopeMeters support not just one or two bus systems but all commonly seen
industrial buses. From the lower speed AS-i and CAN to the higher speed Ethernet
100Base-T based systems are covered by a single instrument. A simple menu
structure allows for selecting the main bus type and, where applicable,
sub-types listed in a sub-menu for easy selection. Tested parameters and
reference values are then set according the selection made.
All common bus types are supported and accessible through a simple menu
structure
Large color screen The large color screen of the 225C
and 215C shows the individual parameters with validation, the actual measured
value, the minimum and maximum values recorded over time, and the reference
values used for the validation. The choice of parameters differs with the bus
type and may include bias voltage, signal high- and low-levels, rise- and
fall-times, in-band and out-of-band noise levels, jitter, pulse width, baudrate,
and more. The activity indicators tell you the data ?ow is ongoing and they stop
?ashing the moment communications come to a halt.
Making test connections The large screen also gives
wiring information for each of the supported bus types, giving the user guidance
in making the test connections. A set of break-out adapters is included with the
225C and 215C to give access to each of the wires and pins of the commonly used
connection systems M12, DB-9 and RJ-45.
On screen ‘help’ information includes visual guidance on making the test
connections. The independently isolated input channels of the 225C support truly
differential measurements on bus systems.
BHT190 Break-out adapter with DB-9 connectors gives access to all individual
wires and pins of the connection system.
Eyepattern Mode The Fluke 225C and 215C can make the
signal quality validation as soon as electrical signals are passed along the
network, without looking at the data content. They ?nd errors like improper
cable connections, bad contacts, incorrect grounding and missing or super?uous
terminators. In the eye-pattern mode, a waveform display is built over
successive signal passes to give you a visual indication of overall signal
quality, noise levels and signal jitter, using the scope’s user selectable
persistence mode.
Eyepattern mode allows for a visual check of signal quality
Floating independently isolated input channels Thanks to
the independently isolated input channels and the ?oating inputs, the ScopeMeter
can take truly ?oating differential measurements from balanced 2-wire systems
such as RS-485 and CAN, giving a high level of suppression for common mode
disturbances and noise. One input channel can be connected to measure the
voltage between the two signal wires, and the other can be connected to measure
the common mode voltage over ground at the same time, independently. This way,
you may also measure the signals passing through the twisted wires of the
100Base-T Ethernet.
Isolated, floating channels give a high immunity to common mode noise and
allow for direct measurements on balanced, two-wire systems including Ethernet
100Base-T.
Fluke 225C compared with other ScopeMeters All
ScopeMeters allow you to perform the basic electrical tests (such as copper
resistance and isolation tests) on an electrical system or a cable. The Fluke
125 offers a cost-effective solution for making tests on industrial buses and
networks, using a common reference (‘ground’) connection. The Fluke 125 also
includes a fully featured 40 MHz Industrial ScopeMeter. The 225C gives more
extensive industrial bus signal analysis capabilities. Thanks to the isolated
channel structure, the 225C gives a far better immunity to common mode noise and
disturbances and can measure common mode voltages separately. On top, the 225C
comes with higher measurement speeds and gives you all the measurement
capabilities associated with the 190C Series.
Specifications
| Specifications |
| Bandwith |
|
| Sample rate: |
|
| Bus health test: |
|
Verifies the electrical parameters of industrial bus
systems using automatic measurement and analysis functions. Next to
that, an Eyepattern mode is provided for visual inspection of signal
quality. | |
| Parameter classification: |
|
Default values: |
| • |
well within limits = ‘good’, gives green tick mark |
| • |
within specified percentage of the limit values = ‘weak’,
gives orange tickmark |
| • |
beyond limit values = ‘bad’, gives red tickmark |
|
Limits values, as a default, are based on industry
standard for the selected bus type or may be set by the user. The
tolerance band (percentage) taken into account for the
classification ‘weak’ may be altered by the user.
| |
| Bus systems supported: |
| • |
AS-i (EN50295, 166 kb/s); |
| • |
CAN-bus (ISO-11898, up to 1 Mb/s); |
| • |
Modbus 232 (EIA-232 up to 115 kb/s); |
| • |
Modbus 485 (EIA-485 up to 10 Mb/s); |
| • |
Foundation Fieldbus H1 (61158 type 1, 31.25 kb/s); |
| • |
Profibus DP (EIA-485 up to 12 Mb/s); |
| • |
Profibus PA (61158 type 1, 31.25 kb/s); |
| • |
Ethernet 10Base2 (coaxial, 10 Mb/s); |
| • |
Ethernet 10BaseT (UTP, 10 Mb/s); |
| • |
Ethernet 100BaseT (100 Mb/s); |
| • |
RS-232 (EIA-232, up to 115 kb/s); |
| • |
RS-485 (EIA-485, up to 10 Mb/s). | |
| Modes: |
| • |
Waveform Parameter analysis with automatic read-out and
parameter validation (good / weak / bad); test limits are based on
industry standards or may be set by the user. |
| • |
Eyepattern display mode. | |
| Measured parameters (where
applicable): |
| • |
bias voltage level, |
| • |
signal amplitude, |
| • |
pulse width or baud rate, |
| • |
risetime, |
| • |
fall time, |
| • |
jitter, |
| • |
signal distortion, |
| • |
noise HF, |
| • |
noise LF, |
| • |
in-band noise. | |
| Eyepattern display mode: |
|
Gives waveform display of bus signals with user selectable
persistence of the display. Timebase, attenuator and persistence
settings may be altered by the user. | |
| Persistence modes: |
|
off – short – medium – long –
infinite | |
Includes:
- Fluke Networks 225C/003 ScopeMeter Color 200MHz Oscilloscope
- Fluke VPS 200-G 10:1 Voltage Probe Set Grey
- Fluke VPS 200-R 10:1 Voltage Probe Set Red
- Fluke 1000v Hard Point Test Leads (1 Red - 1 Black)
- Fluke BHT 190 Bus Health Test Adapter
- Fluke OC4USB Optical Interface Cable w/ Intruction Sheet
- Flukeview Scopemeter Software SW90W
- AC Adapter/Charger
- Fluke ScopeMeter 225C Safety Information
- Fluke ScopeMeter Accessories Guide
- User Manual On CD-ROM
- Hard Carrying Case
|