MT04 - Fluke ESA601 Electrical Safety Analyzer Tester

Fluke ESA601 Electrical Safety Analyzer

Tests medical equipment to both US and international standards

Includes Carrying Case & Accessories As Listed

ESA 601 ESA-601

BC# 16053





Price: $ 2,995.00 / Each


 
 
 
Condition Refurbished
Warranty 90 Day Exchange
Included
  • Fluke ESA601 Electrical Safety Analyzer (BC# 16053) 
  • Test Leads (1-Red, 1-Black)
  • Fluke Biomedical ESA601 Software
  • Power Cord
  • RS232 PC Interface Cable
  • Hard Copy User Manual
  • Carrying Case
 

Fluke ESA601 Electrical Safety Analyzer


ESA601 Electrical Safety Analyzer tests medical equipment to both US and international standards. Users simply flip a switch to change between AAMI or IEC electrical safety testing load. The US version includes overlays in AAMI or IEC nomenclature so technicians use the terms that are most familiar to them. Multiple language overlays, outlets, and power cords are available for convenient use in many countries.

Ten applied part connections allow for lead-toground (patient), lead-to-lead (patient auxiliary), and lead isolation (mains on applied part) leakage testing of equipment with multiple applied parts. Designed for on-the-go testing, the portable analyzer is lightweight and compact and comes with a sturdy handle for easy carrying.


Key features
  • Selectable AAMI or IEC test loads
  • Ten applied parts-lead connectors
  • 90 V (min) to 264 V (max) autoswitching power supply
  • Dual-lead leakage and dual-lead voltage tests
  • Easy-to-read display
  • Compact and portable
  • Ansur plug-in software available to automate testing and document results
  • Multiple outlets and power cords for compatibility in multiple countries
  • Overlays in English, German, French, and Italian
  • Overlay for USA version with either IEC or AAMI nomenclature
  • RS-232 serial port for PC control and printing

Specifications:


Power Mains power operating range
90 min to 264 max V ac (47 Hz to 63 Hz), autoswitching
Power ratings
16 A at 264 V max
Mains inlet The instrument uses a standard  IEC 60320-1/C20 mains inlet rated at 16 A and 250 V for
class-1 equipment in cold conditions
Voltage measurements Autoranging
Yes
Display units
V
Display resolution
1 V
Range (mains voltage)
90 V to 264 V true RMS
Range (accessible voltage)
0 V to 264 V true RMS
Accuracy
± 2 % of reading ± 2 V
Frequency response
DC to 1000 Hz (-3 dB point)
Crest factor
< 3
DC input impedance
1 M?
Earth-resistance
measurements
Autoranging
Yes
Display units
?
Display resolution
0.001 ?
Range
0 ? to 1.999 ?
Accuracy
± 2 % of reading ± 5 M? Current source amplitude 1 A DC (± 10 %)
Insulation measurements Autoranging
Yes
Display units
M?
Display resolution
0.1 M?
Range
0.5 M to 100 M?
Accuracy
0.5 M? to 20 M?, ± 2 % of  reading, ± 200 k?; above 20 M?, ± 5 % of reading, ± 200 k?
Voltage source amplitude
500 VDC (± 10 %)
VDE differential current Autoranging
Yes
Display units
µA
Display resolution
10 µA
Range
10 µA to 10000 µA
Accuracy
± 2 % of full scale
Leakage-current measurements
Autoranging
Yes
Display units
µA
Display resolution
1 µA
Configuration
RMS current flowing through  the ANSI/AAMI ES1 1993 or IEC60601-1 test load
Measurement range
0 µA to 8000 µA true RMS
Accuracy
± 1 % of reading ( ± 2 µA) @ dc  and 25 Hz to 1000 Hz*; ± 2.5 %
of reading (± 2 µA) 1 kHz to 200 kHz*
*Full scale input
Accuracy of mains-on-applied-part leakage  currents: ± 2 % of reading ± 6 µA
Measururing instrument frequency response
DC to 1 MHz (-3 dB)
Crest factor
< 3
Input impedance
Per figure 15 of IEC601-1 or AAMI ES 1
Applied-part connections The instrument contains ten banana jacks that serve as the applied-part
connectors RA (or R and AP1), RL (or N and AP2), LA (or L and AP3),
LL (or F  and AP4), and V1-V6 (or C1-C6  and AP5-AP10)
RS-232 serial port The ESA601 utilizes a null modem serial cable connection to its RS-232 port.
This port is used to Provide test-result outputs (sent in ASCII format when the PRINT
pushbutton is pressed) to a computer or serial ASCII printer
Download processor firmwareProvide an interface for remote operation of the ESA601
Protection circuitry All signal I/O connections,  excluding the RS-232 port and  earth connections,
withstand  a continuous input of 264 Vac, 47 Hz to 63 Hz, or ± 264 Vdc without
causing permanent  damage. (Blowing a fuse does not cause permanent damage)
The mains input is protected by a double-pole circuit breaker
Temperature

Operating
10 °C to 40 °C (50 °F to 104 °F)
Storage
-25 °C to 50 °C (-13 °F to 122 °F)
Maximum Humidity
80 % relative humidity up to 31 °C (88 °F), decreasing
linearly to 50 % relative humidity at 40 °C (104 °F)

Size
Dimensions (WxDxH)
21.1 cm 24 cm x 7.6 cm (8.2 in x 9.8 in x 3 in)
Weight
2.4 kg (5.2 lb)