Fluke 190-102 kit with accessories

Fluke 190-102 ScopeMeter 100MHz 2CH 1.25GS/s

Fluke 190-204 kit with accessories

Fluke 190-204 ScopeMeter 200MHz 4CH 2.5GS/s

Fluke 190M-4 4 Channel 200 MHz Medical ScopeMeter

$6,359.00
Availability: Out of stock
SKU
1H236

Condition: Refurbished / Calibrated

Warranty: 1 YEAR WARRANTY

Request a Quote for

Have Questions or doubts? Submit the following request and expect our detailed quote within 24 hours!

we are commited to win your business!

 Fluke 190M-4 Medical Scopemeter
The 190M Medical ScopeMeter portable oscilloscope is a high-performance test tool built upon the legacy of Fluke and Fluke Biomedical oscilloscopes in partnership with real customers like you. The 190M is available with choice of two or four channels and offers an unprecedented level of performance, ruggedness, and portability. With the combined power of a high-performance oscilloscope, multimeter and paperless recorder in an easy-to-use test tool, the 190M is the one test tool you can rely on to tackle just about any troubleshooting task in the field.

To minimize downtime and repair costs, you need to get to the root cause of problems as quickly as possible. The 190M offers a number of unique features to help you quickly set up the scope and diagnose difficult problems like intermittent events, signal fluctuations or drift.

Extend your arsenal of troubleshooting capabilities with the new Fluke Biomedical 190M Medical ScopeMeter portable oscilloscope, designed to meet the demands of field service professionals.

Features:
  • Two or four electrically-isolated inputs
  • Fast sampling rate, up to 2.5 GS/s on two channels simultaneously with up to 400 ps resolution
  • Deep memory: 10,000 samples per channel waveform capture so you can zoom in on the details (scope mode)
  • Dedicated 5000 count digital multimeter in two-channel model
  • Quad meter measurements via scope BNC inputs in four channel model
  • Connect-and-Viewル triggering for intelligent, automatic triggering on fast, slow and even complex signals
  • Frequency spectrum using FFT-analysis
  • High-resolution, non-interlaced video
  • Smart averaging
  • ScopeRecord roll mode gives 30,000 points per input channel and capture waveform sample data for up to 48 hours
  • TrendPlot, trend measurement readings for up to 22 days
  • Advanced automatic measurements, power (Vpwm, VA, W, PF) and time (mAs, V/s, w/s)
  • Two USB ports make it easy to transfer data to a PC and store unlimited waveforms, screen captures and instrument setups on USB memory devices
  • New high-perfomance Li-ion battery technology delivers the longest battery life on the market
  • Easy-access battery door for quick swaps in the field
  • Security slot locks down oscilloscope with Kensington lock while unattended
  • Environmentally tested to meet IP-51 and withstand 3 g vibration or 30 g shock

Specifications:
Oscilloscope modes
Vertical deflection
Number of channels 4
Bandwidth 200 MHz
Rise time 1.7 ns
Number of scope inputs 4 input channels
Channel architecture All inputs fully insulated from each other and from ground Inputs may be activated in any combination
Input coupling AC or DC, with ground level indicator
Input sensitivity 2 mV/div to 100 V/div, plus variable attenuation
Bandwidth limiter User selectable: 20 kHz, 20 MHz or full bandwidth
Normal/invert/variable On each input channel, switched separately
Extended offset Not avalable currently
Input voltage CAT III 1000 V/CAT IV 600 V rated, see general specifications for further details
Vertical resolution 8 bit
Accuracy ± (2.1 % of reading + 0.04 x range/div) @ 5 mV/div to 100 V/div
Input impedance 1 MO ± 1 %/14 pF ± 2 pF
Horizontal
Maximum real-time sample rate
(sampled simultaneously)
2.5 GS/s (2ch) 1.25 GS/s (4ch)
Record length Up to 10,000 samples per channel
Time base range 2 ns/div to 4 s/div
Time base in a 1-2-4-sequence Slower time/division settings using ScopeRecordル roll mode (see recorder mode)
Maximum record length 10,000 samples per channel in scope mode
30,000 points per channel in ScopeRecordル roll mode (see recorder mode)
Timing accuracy ± (0.01 % of reading + 1 pixel)
Glitch capture  8 ns peak detect on each channel (using real time sampling and data compression, at any timebase setting)
Display and acquisition
Display 153 mm (6 in) full-color LCD with LED backlight
Display modes  Any combination of channels; average on/off; replay
Visible screen width 12 divisions horizontally in scope mode
Digital persistence modes Off/short/medium/long/infinite and envelope mode
Waveform mathematics A + B, A ヨ B, A x B, all with user-selectable scaling of resultant;
A versus B (X-Y- mode); frequency spectrum using FFT analysis
Acquisition modes Normal, averaged, auto, single shot, ScopeRecordル roll, glitch capture, waveform compare with automatic pass/fail testing; replay
Trigger and delay
Source Input A, B or external (via meter input) Input A,B,C or D
Modes Automatic Connect-and-Viewル, free run, single shot, edge, delay, dual slope,
video, video line, selectable pulsewidth (channel A only), N-cycle
Connect-and-Viewル Advanced automatic triggering that recognizes signal patterns, automatically sets
up and continuously adjusts triggering, time base and amplitude
Automatically displays stable waveforms of complex and dynamic signals like
motor drive and control signals can be switched off if preferred
Video triggering (on ch. A) NTSC, PAL, PAL+, SECAM; includes field 1, field 2 and line select
High-res, non-interlaced video Non-interlaced video with line-select, for line frequencies in the range 14 kHz up to 65 kHz
Pulse width triggering (on channel A) Pulse width qualified by time allows for triggering < t, > t, = t, ? t, where t is selectable in minimum steps of 0.01 div or 50 ns
Time delay 1 Full screen of pre-trigger view or up to 100 screens (= 1,200 divisions) of post trigger delay
Dual slope triggering Triggers on both rising and falling edges alike
N-cycle triggering Triggers on Nth occurrence of a trigger event; N to be set in the range 2 to 99
Automatic capture of 100 screens
When in oscilloscope mode, the instrument always memorizes the last 100 screensラno specific user setup required.
When an anomaly is seen, the replay button can be pressed to review the full sequence of screen events over and over.
Instrument can be set to trigger on glitches or intermittent anomalies and will operate in baby-sit mode capturing 100
specified events.
Replay Manual or continuous replay. Displays the captured 100 screens as a live animation or under manual control. Each screen has date and time-stamp
Replay storage Two sets of 100 screens each can be saved internally for later recall and analysis
Direct storage of additional sets on external flash memory drive through USB host port
Fast Fourier Transform (FFT) frequency spectrum analysis
Shows frequency content of oscilloscope waveform using Fast Fourier Transform
Window Automatic, hamming, hanning or none
Automatic window Digitally re-samples acquired waveform to obtain optimum frequency resolution in FFT resultant
Vertical scale Linear/logarithmic (in volts or amps)
Frequency axis Logarithmic frequency range automatically set as a function of timebase range of oscilloscope
Waveform compare and pass/fail testing
Waveform Compare Provides storage and display of a reference waveform for visual comparison with
newly acquired waveforms. Reference is derived from an acquired waveform and
can be modified in the oscilloscope or externally using FlukeView Software.
Pass/Fail Testing In waveform compare mode, the oscilloscope can be set to store only matching
(pass) or only non-matching (fail) acquired waveforms in the replay memory bank
for further analysis
Automatic scope measurements
V dc, V ac rms, V ac + dc, Vpeak max, Vpeak min, Vpeak to peak, A ac, A dc, A ac + dc, frequency (in Hz), rise time
(using cursors), fall time (using cursors), phase (between any 2 inputs), pulse width (pos./neg.), duty cycle (pos./neg.),
temperature °C, temperature °F (not for Japan), dBV, dBm into 50 O and 600 O
Advanced power and motor drive functions V/Hz Ratio (190M-2 only), Power Factor (PF), watts, VA, VA reactive, VPWMac and VPWM (ac + dc) for measurement on pulse width modulated motordrives and frequency inverters
Advanced functions mA×s (Current-over-time, between cursors); V×s (voltage over time, between cursors); W×s (energy, between cursors)
Cursor measurements
Source On any input waveform or on mathematical resultant waveform (Excluding X-Y-mode)
Dual horizontal lines Voltage at cursor 1 and at cursor 2, voltage between cursors
Dual vertical lines Time between cursors, 1/T between cursors (in Hz), voltage between markers, rise time with markers, fall time with markers; Vrms between cursors, watts between cursors
Single vertical line Min/max and average voltage at cursor position; frequency and rms-value of individual frequency component in the FFT resultant
ZOOM Ranges from full record overview to zoom-in up to sample level at any record length
Meter Modes
Meter inputs Via BNC scope inputs
Number of readings Up to 4 simultaneously
Maximum resolution 99 counts
Input impedance 1 MO ± 1 %/14 pF ± 2 pF

Advanced meter functions
Auto/manual ranging, relative measurements (Zero reference),
TrendPlotル recording
The specified accuracy is valid over the temperature range 18 °C to 28 °C Add 10
% of specified accuracy for each degree C below 18 °C or above 28 °C
Voltage
Vdc accuracy ± (0.5 % + 5 counts)
Vac true rms accuracy 15 Hz to 60
Hz: 60 Hz to 1 kHz: 60 Hz to 20 kHz:
 ± (1.5 % + 10 counts)
± (2.5 % + 15 counts)
Vac+dc true rms accuracy 15 Hz to
60 Hz: 60 Hz to 1 kHz: 60 Hz to 20 kHz:
± (1.5 % + 10 counts)
± (2.5 % + 15 counts)
Voltmeter ranges 500 mV, 5 V, 50 V, 500 V, 1,000 V
Resistance
Ranges Feature/function not available for this model
Accuracy
Other meter functions
Continuity Feature/function not available for this model
Diode test
Current (A) A dc, A ac, A ac + dc using an optional current clamp or shunt
Scaling factors: 0.1 mV/A, 1 mV/A to 100 V/A and 400 mV/A
Temperature With optional accessories. Scale factors 1 °C/mV or 1 °F/mV
Recorder Modes
ScopeRecordル Roll Mode
Dual or multiple input waveform storage mode, using deep memory
Source and display Any combination of inputs, up to four channels
All channels sampled simultaneously
Bandwidth 20 MHz or 20 kHz, user selectable
Memory depth 30,000 data points, each holding min/max pair of information
Min/max values Min/max values are created at samples that are measured at high sample rate, ensuring capture and display of glitches
Recording modes Single sweep, continuous roll,
Start-on-trigger (through any channel),
Stop-on-trigger (through any channel)
Stop-on-trigger ScopeRecord mode can be stopped by an individual trigger event or by an interruption of a repetitive trigger signal through any input channel
Horizontal scale Time from start, time of day
Zoom Ranges from full record overview to zoom in up to sample level, at any record length
Memory Two multiple input ScopeRecord waveforms can be saved internally for later recall and analysis. Direct storage on external flash memory drive through USB host port
ScopeRecordル Roll mode sample rate and recording timespan
Time base range 5 ms/div to 2 min/div
Recorded timespan 6 sec to 48 hr
Time/division in ムview allメ mode 0.5 s/div to 4 h/div
Glitch capture 8 ns
Sample rate 125 MS/s
Resolution 200 µsec to 4.8 sec
Trendplotル Recording
Multiple channel electronic paperless recorder graphically plots, displays and stores results of up to four automatic scope measurements or a DMM-reading over time
Source and display Any combination of scope measurements, made on any of the input channels, or DMM reading (two-channel instruments)
Memory depth 18,000 Points (sets) per measurement; each recorded sample point contains a minimum, a maximum and an average value, plus a date and time stamp
Ranges Normal view: 5 s/div to 30 min/div
In view-all mode: 5 min/div to 48 hr/div (overview of total record)
Recorded time span Up to 22 days, with a resolution of 102 seconds
Recording mode Continuous recording, starting at 5 s/div with automatic record compression
Measurement speed 3 Automatic measurements per second or more
Horizontal scale Time from start, time of day
Zoom Up to 64x zoom-out for full record overview, up to 10x zoom-in for maximum detail
Memory Two multiple input TrendPlot records can be saved internally for later recall and analysis. Direct storage on external flash memory drive through USB host port
Cursor measurements: all recorder modes
Source Any waveform trace in any waveform display mode (Scope, ScopeRecord or TrendPlot)
Dual vertical lines Cursors may be used to identify min, max or average value of any datapoint in a record, with time between cursors, time from start or absolute time
General specifications
Input voltage range
Rated maximum floating voltage CAT III 1000 V/CAT IV 600 V
(Maximum voltage between any contact and earth-ground voltage level)
Maximum probe voltage CAT III 1000 V/CAT IV 600 V
(Maximum voltage between any contact and earth-ground voltage level)
Maximum BNC input voltage CAT IV 300 V (Maximum voltage on BNC input directly)
Maximum voltage on meter input CAT III 1000 V/CAT IV 600 V (Safety designed banana input connectors)
Memory save and recall
Memory locations (internal) 15 Waveform memories plus 2 recording memories
15 waveform memory locations Stores ScopeTrace waveform data (2 traces each) plus screen-copy plus corresponding setup
Two recording memories Each may contain:
ユ a 100-screen replay sequence, or
ユ a ScopeRecord roll-mode recording (two traces), or
ユ a TrendPlot recording of up to four measurements
External data storage ユ On PC, using FlukeViewル Software, or
ユ Direct storage on external flash memory drive (maximum 2 GB) through USB host port
Screencopies ユ On PC, using FlukeViewル Software, or
ユ Internally (in instrument), which can be copied on to external flash memory drive as .BMP-file through USB host port
Volatility Measurement data is initially stored in RAM, which is maintained by the main battery with a 30-seconds back-up when battery is exchanged
When storing data, this is written in non-volatile flash-ROM
Real-time clock Provides date and time stamp information for ScopeRecord, for 100-screen replay sequences and for TrendPlot recordings
Case
Design Rugged, shock-proof with integrated protective holster.
Handstrap and hangstrap included as standard Kensington lock supported to lock down instrument when left unattended
Drip and dust proof IP 51 according to IEC 529
Shock and vibration Shock 30 g, vibration (sinusoidal) 3 g according to MIL-PRF-28800F Class 2
Display size 127 mm x 88 mm (153 mm/6.0 in diagonal) LCD
Resolution 320 x 240 pixels
Contrast and brightness User adjustable, temperature compensated
Brightness 200 cd/m2 typical using power adapter, 90 cd/m2 typical using battery power
Mechanical data
Size (HxWxD) 265 mm x 190 mm x 70 mm (10.4 in x 7.5 in x 2.8 in)
Weight (including battery) 2.2 kg (4.8 lb)
Power
Line power Mains adapter/battery charger BC190 included, version depending on country
Battery power Rechargeable double capacity Li-Ion battery (included). Battery swappable through easily-accessible battery door at the rear of the instrument
Battery charge indicator Battery has built-in status indicator for use with external charger, next to battery status indicator on instrument screen
Battery operating time (with backlight low) Up to seven hours using BP291
Battery charging time 5 hours BP291
Battery power saving functions Auto power-down with adjustable power-down time; auto display off with adjustable power-down time; on-screen battery power indicator
Safety
Compliance EN 61010-1:2001, Pollution Degree 2; CAN/CSA C22.2, No. 61010-1-04, with approval; UL61010B; ANSI/ISA-82.02.01
Environmental
Operating temperature 0 °C to +40 °C; +40 °C to +50 °C Excluding battery
Storage temperature -20 °C to +60 °C
Humidity 10 °C to +30 °C: 95 % RH Non-condensing
30 °C to +40 °C: 75 % RH Non-condensing
40 °C to +50 °C: 45 % RH Non-condensing
Maximum operating altitude Up to 2,000 m (6666 ft) for CAT IV 600 V, CAT III 1000 V; up to 3,000 m (10,000 ft) for CAT III 600 V, CAT II 1000 V
Maximum storage altitude 12 km (40,000 ft)
Electro-magnetic-compatibility (EMC) EN 61326 (2005-12) For emission and immunity
Interfaces Two USB ports provided. Ports are fully insulated from instrumentメs floating measurement circuitry.
USB-host port directly connects to external flash memory drive (up to 2 GB for storage of waveform data, complete datasets in which data and setup information is included, instrument settings and screen copies.
A mini-USB-B is provided which allows for interconnection to PC for remote control and data transfer under PC-control.



For full Fluke 190M-4 specifications, please click here: Fluke 190M-4

Fluke 190M-4 ScopeMeter 4 Channel 200MHz 2.5 GS/s Color Oscilloscope

This Unit Is The Fluke 190-204 ScopeMeter With Medical Option Installed!

With the combined power of a high-performance oscilloscope, multimeter and paperless recorder in an easy-to-use test tool, the 190M is the one test tool you can rely on to tackle just about any troubleshooting task in the field

Includes Carrying Case & Accessories As Listed

Fluke 190M-4 Scopemeter 190M-4-Scopemeter Handheld Oscilloscope Models On Sale Warranty Calibration Backed by The Best Service and Lowest Prices in the Industry.

BC# 34092-L/T*

  • Fluke 190M-4 Medical ScopeMeter 4 Channel 200MHz Oscilloscope (BC# 34092-L/T*) 
  • (4) Fluke Voltage Probes
  • (4) Fluke Ground Leads w/ Mini Clips
  • Fluke MA-190 Kit Medical Accessory Kit
  • USB PC Interface Cable
  • AC Adapter/Charger
  • SCopemeter Test Tools Software CD-ROM SW90W
  • Strap For Unit
  • Carrying Case (G)