Fluke AC85A Large Jaw Alligator Clips (1 Red, 1 Black)
Fluke AC20 Alligator Clips (1 Red, 1 Black)
Fluke TP1 Flat Blade Test Pins (1 Red, 1 Black)
Fluke TP4 4mm Test Pins (1Red, 1 Black)
Fluke BB120 BNC to Banana Connector
Fluke PM9080 Optical Interface Cable
AC Adapter/Charger
Flukeview SW43W PQ Analyzer Software
Fluke Scopemeter Accessories Guide
Hard Copy User Manual
Hard Carrying Case
The Fluke 43 is a single phase power quality analyzer which combines the most
useful capabilities of a power quality analyzer, multimeter and scope. It
measures power harmonics, captures voltage sags, transients and inrush current.
The Fluke 43's monitoring functions help track intermittent problems and power
system performance.
The Fluke 43 Power Quality Analyzer performs the measurements you need to
maintain power systems, troubleshoot power problems and diagnose equipment
failures.
Features include:
New! NiMH Battery provides extended operating time of 6.5 hours
Combines the most useful capabilities of a power quality analyzer,
multimeter and scope
Simulates 3-phase power (assuming balanced loads) from a single-phase
measurement
Trends voltage, current, frequency, power harmonics and captures voltage
sags, transients and inrush current
Monitoring functions help track intermittent problems and power system
performance
Menus use familiar electrical terminology
New! Toggle through the most commonly used power quality modes with a
single keystroke
Records two selectable parameters for up to 16 days
New! 20 measurement memories to save/recall screens and data with cursor
readings
FlukeView® software can log harmonics and all other readings over time and
provides a complete harmonics profile up to the 51st harmonic
Measures resistance, diode voltage drop, continuity, and capacitance
Users / applications manual and power quality video to help answer tough
questions
Software and optically isolated interface cable
Technical Data
Input Characteristics
Input impedance: 1 MW, 20 pF
Voltage Rating: 600V rms, CAT III
Volt/Amps/Hertz Display
True-rms voltage (ac+dc) Ranges: 5.000V,
50.00V, 500.0V, 1250V* Accuracy: ±(1% +10 counts) True-rms
current (ac + dc) Ranges: 50.00A, 500.0A, 5.000 kA, 50.00 kA
Accuracy: ±(1% +10 counts) Mains frequency Ranges:
40.0 to 70.0 Hz Accuracy: ±(0.5% +2 counts)
Power Display
Watts, VA, VAR Ranges: 250 W, 2.50 kW, 25.0
kW, 250 kW, 2.50 MW, 250 MW Accuracy: ±(4% + 4 counts) Power
Factor, PF Displacement Power Factor, DPF Range: 0.00 to 0.25
Accuracy: Not specified Range: 0.25 to 1.0 Accuracy: ±0.04
Harmonics Display
Voltage Ranges: 1st to 51st harmonic Accuracy:
±(3% +2 counts) to ±(15% +5 counts) Current Ranges:
1st to 51st harmonic Accuracy: ±(3% +8 counts) to ±(5% +8 counts)
Power Ranges: 1st to 51st harmonic Accuracy: ±(5% +2
counts) to ±(30% +5 counts) Line frequency Ranges: 40
Hz to 70 Hz fundamental Accuracy: ±0.25 Hz Phase
Ranges: 2nd to 51st harmonic Accuracy: ±3 º to ±15 º
K-factor Ranges: 1.0 to 30.0 Accuracy: ±10%
Sags and Swells Recording
Recording times: 4 min to 16 days (selectable)
True-rms voltage: Ranges: 5.000V, 50.00V, 500.0V,
1250V* Accuracy: ±(2% +10 counts) True-rms current
Ranges: 50.00A, 500.0A, 5.000 kA, 50.00 kA Accuracy: ±(2% +10 counts)
Other Recording
Recording times: 4 min to 16 days (selectable)
Parameters:Choose up to two from one of the
groups below V/A/Hz: Line voltage, current,
frequency Power: Watts, VA, VAR, PF, DPF, frequency
Harmonics: THD, harmonic voltage, (or current, or
power), frequency, % of total, phase Ohms: Ohms,
diode, continuity, capacitance Temperature:
Temperature Scope: DC voltage, dc current, ac
voltage, ac current, frequency, pulse width, phase, duty cycle, peak max,
peak min, peak min-max, crest factor
Transient Capture
Minimum pulse width: 40 ns Voltage
threshold settings: 20%, 50%, 100%, 200% above or below normal
voltage Min voltage and max voltage at cursor:
Ranges: 10V, 25V, 50V, 125V, 250V, 500V, 1250V Accuracy: ±5% of full
scale
Inrush Capture
Current ranges: Ranges: 1A, 5A, 10A, 50A,
100A, 500A, 1000A Inrush times: Ranges: 1s, 5s, 10s,
50s, 100s, 5 min Cursor readings, Current at cursor
Ranges: 12.5A, 25A, 50A, 125A, 250A, 500A, 1250A, 2500A, 5 kA Accuracy:
±5% of full scale Time between cursors Ranges: 4 to
235 pixels (1 pixel = inrush time/250) Accuracy: ±(0.2% + 2 pixels)
Scope Display
Time ranges: Ranges: 20 ns/div to 60 s/div
Max sampling rate: Ranges: 25 MS/s
Bandwidth: Voltage channel [1]: 20 MHz at inputs, 1
MHz with TL24 Leads Current channel [2]: 15 kHz at inputs, 10 kHz with
80i-500s Probe Coupling: AC, DC Vertical
sensitivity: Ranges: 5 mV/div to 500V/div Vertical
resolution: 8 bit (256 levels) Record
length: 512 samples per channel Timebase
modes: Normal, roll, single Pre-trigger: Up
to 10 divisions Measurements: dc, ac, ac+dc, peak,
peak-peak, frequency, duty cycle, phase, pulse width, crest factor
To printer: Supports HP Laserjet®, Deskjet®,
Epson FX/LQ and Postscript printers with optional PAC91 Printer Adapter
Cable To PC: FlukeView® Power Quality Analyzer
Software included
FlukeView Power Quality Software
Hardware requirements: PC or 100% compatible
with Windows® 3.1, Windows® 95, or Windows NT® . Enough RAM for Windows
operating system. 4 MB hard drive space. Pointing device (mouse)
recommended.