PQ01 - Fluke 43B HandHeld Power Quality Analyzer Meter

Fluke 43B HandHeld Power Quality Analyzer

Trends voltage, current, frequency, power harmonics and captures voltage sags, transients and inrush current

Includes Hard Carrying Case & Accessories As Listed!

43b/003 43/003





Regular Price:$ 2,495.00 / Each
Sale Price:$ 1,995.00 / Each
You Save:$ 500.00 / Each


 
 
 
Condition Refurbished / Calibrated
Warranty 90 Day Exchange
Included
  • Fluke 43B HandHeld Power Quality Analyzer
  • Fluke 80i-500s AC Current Probe
  • Fluke TL24 Test Leads (1 Red, 1 Black) 
  • Fluke AC85A Large Jaw Alligator Clips (1 Red, 1 Black) 
  • Fluke AC20 Alligator Clips (1 Red, 1 Black)
  • Fluke TP1 Flat Blade Test Pins (1 Red, 1 Black) 
  • Fluke TP4 4mm Test Pins (1Red, 1 Black)
  • Fluke BB120 BNC to Banana Connector
  • Fluke PM9080 Optical Interface Cable
  • AC Adapter/Charger
  • Flukeview SW43W PQ Analyzer Software   
  • Fluke Scopemeter Accessories Guide
  • Hard Copy User Manual 
  • Hard Carrying Case
 

The Fluke 43 is a single phase power quality analyzer which combines the most useful capabilities of a power quality analyzer, multimeter and scope. It measures power harmonics, captures voltage sags, transients and inrush current. The Fluke 43's monitoring functions help track intermittent problems and power system performance.

The Fluke 43 Power Quality Analyzer performs the measurements you need to maintain power systems, troubleshoot power problems and diagnose equipment failures.

Features include:

  • New! NiMH Battery provides extended operating time of 6.5 hours
  • Combines the most useful capabilities of a power quality analyzer, multimeter and scope
  • Simulates 3-phase power (assuming balanced loads) from a single-phase measurement
  • Trends voltage, current, frequency, power harmonics and captures voltage sags, transients and inrush current
  • Monitoring functions help track intermittent problems and power system performance
  • Menus use familiar electrical terminology
  • New! Toggle through the most commonly used power quality modes with a single keystroke
  • Records two selectable parameters for up to 16 days
  • New! 20 measurement memories to save/recall screens and data with cursor readings
  • FlukeView® software can log harmonics and all other readings over time and provides a complete harmonics profile up to the 51st harmonic
  • Measures resistance, diode voltage drop, continuity, and capacitance
  • Users / applications manual and power quality video to help answer tough questions
  • Software and optically isolated interface cable
Technical Data
Input Characteristics Input impedance: 1 MW, 20 pF
Voltage Rating: 600V rms, CAT III
Volt/Amps/Hertz Display True-rms voltage (ac+dc) Ranges: 5.000V, 50.00V, 500.0V, 1250V* Accuracy: ±(1% +10 counts)
True-rms current (ac + dc) Ranges: 50.00A, 500.0A, 5.000 kA, 50.00 kA Accuracy: ±(1% +10 counts)
Mains frequency Ranges: 40.0 to 70.0 Hz Accuracy: ±(0.5% +2 counts)
Power Display Watts, VA, VAR Ranges: 250 W, 2.50 kW, 25.0 kW, 250 kW, 2.50 MW, 250 MW Accuracy: ±(4% + 4 counts)
Power Factor, PF Displacement Power Factor, DPF Range: 0.00 to 0.25 Accuracy: Not specified Range: 0.25 to 1.0 Accuracy: ±0.04
Harmonics Display Voltage Ranges: 1st to 51st harmonic Accuracy: ±(3% +2 counts) to ±(15% +5 counts)
Current Ranges: 1st to 51st harmonic Accuracy: ±(3% +8 counts) to ±(5% +8 counts)
Power Ranges: 1st to 51st harmonic Accuracy: ±(5% +2 counts) to ±(30% +5 counts)
Line frequency Ranges: 40 Hz to 70 Hz fundamental Accuracy: ±0.25 Hz
Phase Ranges: 2nd to 51st harmonic Accuracy: ±3 º to ±15 º
K-factor Ranges: 1.0 to 30.0 Accuracy: ±10%
Sags and Swells Recording Recording times: 4 min to 16 days (selectable)
True-rms voltage: Ranges: 5.000V, 50.00V, 500.0V, 1250V* Accuracy: ±(2% +10 counts)
True-rms current Ranges: 50.00A, 500.0A, 5.000 kA, 50.00 kA Accuracy: ±(2% +10 counts)
Other Recording

Recording times: 4 min to 16 days (selectable)
Parameters:
Choose up to two from one of the groups below
V/A/Hz: Line voltage, current, frequency
Power: Watts, VA, VAR, PF, DPF, frequency
Harmonics:
THD, harmonic voltage, (or current, or power), frequency, % of total, phase
Ohms: Ohms, diode, continuity, capacitance
Temperature: Temperature
Scope: DC voltage, dc current, ac voltage, ac current, frequency, pulse width, phase, duty cycle, peak max, peak min, peak min-max, crest factor

Transient Capture Minimum pulse width: 40 ns
Voltage threshold settings: 20%, 50%, 100%, 200% above or below normal voltage
Min voltage and max voltage at cursor: Ranges: 10V, 25V, 50V, 125V, 250V, 500V, 1250V Accuracy: ±5% of full scale
Inrush Capture Current ranges: Ranges: 1A, 5A, 10A, 50A, 100A, 500A, 1000A
Inrush times: Ranges: 1s, 5s, 10s, 50s, 100s, 5 min
Cursor readings, Current at cursor Ranges: 12.5A, 25A, 50A, 125A, 250A, 500A, 1250A, 2500A, 5 kA Accuracy: ±5% of full scale
Time between cursors
Ranges: 4 to 235 pixels (1 pixel = inrush time/250) Accuracy: ±(0.2% + 2 pixels)
Scope Display Time ranges: Ranges: 20 ns/div to 60 s/div
Max sampling rate: Ranges: 25 MS/s
Bandwidth: Voltage channel [1]: 20 MHz at inputs, 1 MHz with TL24 Leads Current channel [2]: 15 kHz at inputs, 10 kHz with 80i-500s Probe
Coupling: AC, DC
Vertical sensitivity: Ranges: 5 mV/div to 500V/div
Vertical resolution: 8 bit (256 levels)
Record length: 512 samples per channel
Timebase modes: Normal, roll, single
Pre-trigger: Up to 10 divisions
Measurements: dc, ac, ac+dc, peak, peak-peak, frequency, duty cycle, phase, pulse width, crest factor
Ohms, Diode,Continuity Ohms: Ranges: 500.0W, 5.000 kW, 50.00 kW, 500.0 kW, 5.000 MW, 30.00 MW Accuracy: ±(0.6% +5 counts)
Diode voltage: Accuracy: ±(2% +5 counts)
Continuity:
Beeper on at < (30W ±¤5W)
Max current: 0.5 mA
Capacitance: Ranges: 50.00 nF, 500.0 nF, 5.000 µF, 50.00 µF, 500.0 µF Accuracy: ±(2% +10 counts)
Temperature** Ranges: -100.0 ºC to 400.0 ºC, -200.0 ºF to 800.0 ºF Accuracy: ±(0.5% +5 counts)
Screen Memories 10
Optically Isolated RS-232 Interface To printer: Supports HP Laserjet®, Deskjet®, Epson FX/LQ and Postscript printers with optional PAC91 Printer Adapter Cable
To PC: FlukeView® Power Quality Analyzer Software included
FlukeView Power Quality Software Hardware requirements: PC or 100% compatible with Windows® 3.1, Windows® 95, or Windows NT® . Enough RAM for Windows operating system. 4 MB hard drive space. Pointing device (mouse) recommended.