Fluke 98 Series II Automotive Dual Channel Scopemeter

Fluke 98 Series II Automotive Dual Channel Scopemeter

Fluke 376 kit with accessories

Fluke 376 FC True RMS Clamp Meter

Fluke 87 IV True RMS Industrial Digital Multimeter

$695.00
Availability: In stock
SKU
10H20

Condition: Refurbished

Warranty: 1 YEAR WARRANTY

Fluke 87 IV Multimeter
The Fluke Model 87 and Model 89 Series IV True RMS Multimeters (hereafter referred to as the “meter”) comply with:

  • EN61010.1:1993
  • ANSI/ISA S82.01-1994
  • CAN/CSA C22.2 No. 1010.1-92
  • 1000V Overvoltage Category III, Pollution Degree 2
  • UL 3111-1

Turning the Meter On
To turn the meter on, turn the rotary switch from OFF to any switch setting.

The ac volts function is assumed in the following discussion. You do not need connections to the input terminals at this time.

If you want a view of the full display (all segments illuminated), press and hold Q while turning the meter on. Release the button when you are done viewing the full display.

Battery Considerations
The meter uses four AA alkaline batteries. The following paragraphs describe several techniques used to conserve battery power.

Automatic Power Off
The display blanks and the meter goes into a “sleep” mode if you have not changed the rotary switch position or pressed a button for a set period. While in Sleep mode, pressing any button turns the meter on. The meter then returns to the display for the function selected with the rotary switch; all previously activated button features (HOLD, Hz, etc.) are discarded.

The automatic power off is preset to 15 minutes. From the setupmenu, you can specify a maximum period of 23 hours, 59 minutes. If you set the period to 0, the meter remains on until you turn the rotary switch to OFF or the batteries become too weak.

Automatic Backlight Off
select A backlight level (low, high, or off.) In low or high, the backlight turns off automatically after a given period. This period is also preset to 15 minutes and can be set to a maximum of 99 minutes from the setup menu. If the period is set to 0, the backlight is on indefinitely and can only be turned off by pressing T or turning the meter off.

Rotary Switch
Turn the meter on by selecting any measurement function (identified with white letters around the rotary switch). The meter presents a standard display for that function (range, measurement units, modifiers, etc.) The display may also be influenced by some of the choices made in Setup.

Use the blue button to select any rotary switch alternate function (labeled in blue letters). You can also use other buttons to choose modifiers for the selected function.

When you turn the rotary switch from one function to another, a display for the new function appears. Button choices made in one function do not carry over into another function.

Specifications:
Maximum Voltage between any Terminal and Earth Ground 1000 V ac/dc
Surge Protection 8 kV peak per IEC 1010.1-92
Fuse Protection for mA or µA inputs
Fuse Protection for A input
44/100 A, 1000 V FAST Fuse
11 A, 1000 V FAST Fuse
Display (LCD) Digital: 50000/5000 primary display, 5000 counts secondary display; updates 4/second.
Analog: 51 segments, updates 40/second
Temperature Operating: -20 °C to +55 °C;
Storage: -40 °C to +60 °C
Altitude Operating: 2000 m;
Storage: 10,000 m
Temperature Coefficient 0.05 x (specified accuracy) / °C (<18 °C or >28 °C)
Electromagnetic Compatibility (EMC) Susceptibility and Emissions: Commercial Limits per EN61326-1
Relative Humidity 0 % to 90 % (0 °C to 28 °C);
0 % to 70 % (28 °C to 55 °C)
Battery Type 4 AA Alkaline, NEDA 15A or LR6
Battery Life 72 hrs typical (with backlight off)
Shock Vibration Per MIL-T-PRF 28800 for Class II instruments
Size 3.94 in x 8 in x 1.97 in (10.0 cm x 20.3 cm x 5.0 cm)
Weight 1.2 lbs (545 g)
Case Sealing IP-42 per IEC 529, Section 3
Compliances Complies with ANSI/ISA S82.01-94, CSA 22.2 No. 1010.1- 92 to 1000 V Overvoltage Category III, Pollution Degree 2.
Certifications (listed and pending) CSA per standard CSA/CAN C22.2 No. 1010.1-92
UL per standard UL3111-1 (pending)
TÜV per standard EN 61010 Part 1-1993 (pending)
DC Voltage 0 to 1000 V
AC Voltage, true RMS 15 mV to 1000 V – 100 kHz bandwidth
Basic Accuracy DC voltage: 0.025 %
AC voltage: 0.4 %
DC Current 0 to 10 A (20 A for 30 seconds)
AC Current, true RMS 25 µA to 10 A (20 A for 30 seconds)
Resistance 0 to 30 M?
Conductance 0 to 50 nS
Capacitance 0.001 nF to 50 mF
Diode Test 3.1 V
Temperature −200 °C to 1350 °C (−328 °F to 2462 °F)
Frequency 0.5 Hz to 1000 kHz





For full Fluke 87 IV product specifications, please click here: AFluke 87 IV

Fluke 87 IV True RMS Industrial Digital Multimeter

Includes Carrying Case & Accessories As Listed 

87-IV 87IV

Fluke 87 IV Fluke-87 IV Multimeter Models On Sale Warranty Calibration Backed by The Best Service and Lowest Prices in the Industry.

BC# 40722-L/T*

  • Fluke 87 IV True RMS Industrial Digital Multimeter (BC# 40722-L/T*)
  • (2) 1000V Hard Point Test Leads
  • User Manual On CD-ROM
  • Carrying Case (G)
Request a Quote for

Have Questions or doubts? Submit the following request and expect our detailed quote within 24 hours!

we are commited to win your business!