Fluke 125 kit with accessories

Fluke 125 40 MHz Industrial ScopeMeter

Fluke 99B II kit with accessories

Fluke 99B 100MHz 2CH 5GSa/s Scopemeter

Fluke 93 ScopeMeter Dual Channel 50 MHz HandHeld Oscilloscope

$795.00
Availability: In stock
SKU
11H27

Condition: Refurbished

Warranty: 90 Day Exchange

Fluke 93 Scopemeter


Features:
- Dual Trace, 50Mhz Bandwidth Scope
- 25 million samples-per-second, 40 ns glitch capture capability
- 3 2/3 digit, 3000-Count Digital Multimeter (DMM)
- Menu-Driven Operator interface for easy operation
- Storage of 10 front panel setups (Meter and Scope Modes) allows for semi-automated operation
- Digital Strage for eight waveforms
- Simultaneous display of four waveforms (any combination of live and stored) allows for useful comparisons
- Auto set configures ScopeMeter to select the best voltage and time base settign for a meaningful display
- Undo feature allows you to step back through the 10 most recent key presses
- True portabillity and three power source choices allow for testing in real-life environments

Tilt Stand: The ScopeMeter is equipped with a multipurpose tilt stand allowing viewing from different angles. The stand can also be used to hang the ScopeMeter at a convenient viewing position, Simply push up on the quick release and tilt the stand.


NEW FUNCTIONS WITH VERSION 4 SOFTWARE
Your ScopeMeter now includes with the latest software release V4. You will find several new functions that are not described. The following list gives the most important changes:

IMPROVED USER INTERFACE
Improved accessibility of the alert function. Switching between METER mode and SCOPE mode no longer influences the original display. Pressing the METER key a second time results in the main meter display.

30Ω RANGE, 0.01Ω RESOLUTION
The 30-Ω range is accessible only in manual Range Mode. Maximum reading: 99.99Ω, Accuracy: ±2.5% ±25 counts.

INVERT WAVEFORM IN BOTH CHANNELS
Channel A can now be inverted just like Channel B.

MORE FREQUENCY COUNTER RESOLUTION
Increased frequency counter resolution to four full digits.


Specifications:

MULTIMETER
DC Volt Ranges: 300 mV, 3V, 30V, and 300V
Accuracy: ±0.5% ±5 counts
AC Volt Ranges: 300 mV, 3V, 30V and 250V
Accuracy: ±1% ±10 counts, 50 Hz to 60 Hz
±2% ±15 counts, 20 Hz to 20 kHz
±3% ±20 counts, 5 Hz to 1 MHz
Additional error ±1% >1 kHz
Accuracy valid from 5% to 100% of range

For <10 Hz with 10:1 probe or <100 Hz direct (1:1 probe), use function Vrms AC + V DC
mV DC Ranges: 300 mV and 3V
Accuracy: ±0.5% ±5 counts

This range has a low=pass filter with a bandwidth of 5 kHz
Ω Ranges: 300Ω, 3 kΩ, 30 kΩ, 300 kΩ, 3 MΩ and 30 MΩ
Accuracy: ±0.5% ±5 counts
Range: 30Ω
Accuracy: ±2.5% ±25 counts
Diode Measuring Current: 0.5 mA
Maximum Voltage: 4V
Display Modes
Frequency The frequency can be displayed within the following parameters:
Range: 1 Hz ... 5MHz
Accuracy: ±0.5%
Resolution: 4 digits
Trace Display The display trace can be switched off
Duty%+, Duty%- Relative on-to-off time of a varying input can be displayed as a percentage
Range: from <2.0% to >98.% for signal amplitudes >10% of the input voltage range.
Resolution: 0.1%
Accuracy ( Logic or pulse waveforms): Within ±0.5%
Accuracy (Sine or triangle waveforms): Within ±1% + ((Voltage Range/RMS Input Voltage) x 1%)
%DELTA Displays the difference after 0% or % Δ is pressed
SCALING 0% and 100% can be set as scale reference, and x is the measured value referred to 0%.
VOLT MATH Results can be displayed in DBV, dBm, dBW, or Audio Watt. The assumed load resistance can be chosen from: 1, 2, 4, 8, 16, 50, 760, 75, 93, 110, 125, 135, 150, 200, 250, 300, 500, 600, 800, 900, 1000, or 1200Ω , depending on the display mode.
Record In meter Mode, the actual value is displayed simultaneously with the maximum, average, and minimum values.
Touch Hold Feature Can be activated by pressing HOLD

OSCILLOSCOPE
Vertical System
DEFLECTION FACTOR 1 mV to 100V per division (5 mV to 100V per division for Model 94) in 102-5 Sequnecy, for time base 60s/ Division to 1ms/dvision. This can be expanded by a factor of 10 with the 10:1 probe.
Vertical Resolution 8 bits, 25 levels per division
DC ACCURACY ± (2% ± 1 digit)
Rise Time Vertical Amplifier response limits the rise time to 7 ns. For time base settings slower than 200 ns the rise time is smaller than the sample resistance, so the measured rise time is unreliable if it is smaller than (2 x s/Div)25
BANDIWTH With 10:1 probe only: > 50 MHz (-3 dB
NONLINEARITY Including Analog To Digital Converter, which will have no missing codes and is monotonic ±(2% ± digit)
MOVE CONTROL RANGE From +4 Divisions to -4 Divisions
DC BALANCE Base line is automatically readjusted after switching the attenuator o rac/dc/ground.
MIN/MAX Acquisition mode at 1 µs per division or slower on Channel A only. Pusle width for 100% probability of detections is 40 ns.
AVERAGE The running average can be set to 256 maximum. In Roll Mode, the average is fixed at 10.
ZOOM Expand or contract view centered around the 4th division, within the limits of the time base and the maximum delay.
HORZONTAL SYSTEM
RANGE 5 ns to 10 ns per division with triggered start.
The Roll Mode is active from 60s to 10s per division.
Single Shots are possible from 5s to 100 ns per division. For time base settings faster thana 1ms, and automatic interpolation takes place. The  useful bandwidth is about 6 MHz
GENERAL
Impedance: 1 M Ω // 25 pF Maximum Voltage: 300V up to 1 MHz (Maximum allowed voltage decreases 6 dB per octave at higher frequencies) The maximum input voltage between any terminal and earth ground is 600V
Input protection: The inputs are protected for line voltages of 600V and surge voltages of 4 kV
Display
LCD Type: Super Twisted Nematic
Active Area: 240x240 pixels, diagonal of 4.7 inches (12 cm)
Trace area: 200x240 pixels
INTERNAL BATTERY POWER
Operating Time: Ni-Cd Pack: 4 Hours (Typical)
Alkaline C-Cell: 4 Hours (KR27/50 or R-14 size can be used. )
Charging Time: 16 hours (typical) While not operating
Charging Current: 100 mA with ScopeMeter ON
200 mA with ScopeMeter OFF
Maximum Temperature During Charging: 45°C
Temperature And Humidity
Operating Temperature: 0°C to 50°C
Storage Temperature: -20°C to 70°C
Relative Humidity: 90% from 20°C to 30°C
70% From 30°C to 50°C
Shock & Vibration
Per MIL-T-28800 for a Class 3 instrument
SIZE (HxWxL)
ScopeMeter Only:  60 mm x 129 mm x 262 mm
(2.4 Inch x 5.1 inch x 10.3 inch)
With Holster:  62 mm x 140 mm x 281 mm
(2.5 Inch  x 5.5 inch x 11.1 inch)
Weight: ScopeMeter Only: 1.5 kG (3.3 lbs)
With Holster: 1.8 kg (4.0 lbs)
Safety
Designed to protection Class II per IEC 348 and UL1244 for 600V
Sealing
Dust and splash proof



For full Fluke 93 specifications, please click here: Fluke 93

Fluke 93 ScopeMeter, Dual Channel 50MHz HandHeld Oscilloscope

AC / DC Ranges:
- 300 mV, 3V, 30V and 250V

Ω Range:
- 30Ω

Includes Carrying Case & Accessories As Listed

Fluke 93 Scopemeter 93-Scopemeter Handheld Oscilloscope Models On Sale Warranty Calibration Backed by The Best Service and Lowest Prices in the Industry.

 

BC# -L/T*


 

  • Fluke 93 ScopeMeter 50MHz ScopeMeter (BC# -L/T*)
  • (2) Flexible Test Leads
  • AC Adapter/Charger
  • User Manual On CD-ROM
  • Carrying Case (G)
Request a Quote for

Have Questions or doubts? Submit the following request and expect our detailed quote within 24 hours!

we are commited to win your business!