The Fluke 572 non-contact thermometers are ideal professional diagnostic
tools for maintenance professionals requiring the most accurate temperature
readings at all distances. The Fluke 572 infrared (IR) measures surface
temperatures, helping to quickly locate lubrication problems, overloads,
short-circuits or misaligned and overheated equipment, reducing work and
follow-up time, and improving performance.
From close-up electrical connections, to distant room balancing checks, the
Fluke 572s can take IR temperature measurements with ease.
Features:
- Backlit display for poorly lit areas
- Last ten temperature readings displayed on bar graph for easy reference
- Enhanced optics (distance to spot ratio up to 60:1) allow measurements of
smaller objects from farther away
- Coaxial three-dot laser sighting system highlights the true diameter of
measurement spots at all distances (90% energy)
- Extra bright appearing 635nm laser (tested to the same safety and power
standards as less bright laser sights) to clearly highlight the targeted area
- Close-focus option available for specialized applications
- MIN/MAX measurements calculations instantly computed
- Audible and visible HI temperature alarm for instant recognition
- Comfortable, overmolded pistol grip makes target sighting easy
- Adjustable emissivity setting (.01 increments) for more accurate
measurement
- Durable hard plastic storage case included
| Technical
Specifications |
| Temperature range |
|
-30 to 900°C |
|
(-25 to 1600
°F) | |
| Display Resolution |
|
0.1°C of reading up to 900°C |
|
0.2°F of reading up to
999.8°F | |
| D:S (Distance to spot size) |
|
60:1 Standard focus |
|
50:1 Close
focus | |
| Minimum measurement diameter |
|
19mm (0.76 in) Standard focus |
|
6mm (0.24 in) Close
focus | |
| Laser sighting |
|
Three point coaxial
laser | |
| Emissivity |
|
Digitally adjustable from 0.10 to 1.0
by 0.01 | |
| Display Accuracy [Assumes ambient
operating temperature of 23°C(73°F) to 25°C(77°F)] |
|
±0.75% of reading |
|
±1% of reading or ±0.75°C (±1.5°F),
whichever is greater | |
| Response time |
|
250 mSec (95% of
reading) | |
| Repeatability |
|
±0.5% of reading or ±1°C (±2°F),
whichever is greater | |
| Spectral response |
|
| Laser Sighting |
|
Laser turns off above ambient
temperature of 40°C (104°F) | |
| Laser Power |
|
Class 2(II) operation; Output <1mW,
wavelength 630-670 nm | |
| Relative humidity |
|
10% to 90% RH non-condensing, at
<30°C (86°F) | |
| Tripod mount |
|
| Power |
|
| Battery life (alkaline) |
| |
13 hours with laser and backlight on
50% | |
| Display hold |
|
| LCD backlit |
|
| Warranty |
|
| Operating temperature |
|
0°C to 50°C |
|
32°F to
120°F | |
| Storage temperature |
|
-20°C to 50°C |
|
-25°F to
120°F | |
| MAX, MIN temperatures |
|
| Audible and visible alarms |
|
| Bar graph display |
|
|