Fluke Networks DTX-1800 Digital Cable
Analyzer
The DTX CableAnalyzer™ Series from Fluke Networks is
the testing platform for today and tomorrow. This revolutionary platform
significantly reduces total time to certify by improving every aspect of the
testing process. It all starts with a Cat 6 Autotest time that’s several times
faster than other testers and fiber testing that’s five times faster. DTX also
gives you a complete solution for 10 Gig testing over copper, Basic Tier 1 fiber
testing, and Extended Tier 2 fiber testing with the industry’s only modular
OTDR. The DTX makes you ready for whatever the world throws at you – today and
tomorrow.
Significantly reduces total time to
certify.
The DTX Digital CableAnalyzer Series gives you a
complete solution that streamlines every aspect of the certification job from
setup, to record fast testing and troubleshooting, to reporting results to the
customer. All told, DTX can save you considerable time and money up to four
hours a day.
Cat 6 certification in 9 seconds
The
DTX-1200 and DTX-1800 perform Cat 6 certification tests in just 9 seconds in
full compliance with industry standards and with superior accuracy. That’s
several times faster than existing testers. This incredible speed means you can
test up to 170 more links in an eight-hour shift.
Troubleshoot
faults twice as fast
When a link fails, the DTX Series provides
quick, easy-to-understand directions to identify the point of failure (distance
from the tester) and the possible reason(s) for the failure.
These
directions not only tell you the problem, but also identify corrective actions
your test technicians can take to solve the problem quickly all without having
to consult the project manager. Instead of spending time executing trial and
error corrections – and re-testing to find out whether the problem has been
resolved the technician knows exactly where to look and what to do to fix the
failing link. Even if only two percent of the cables certified in one shift fail
Autotest, you’ll save as much as two hours of labor time per day of
certifying.
Fast even when you’re not testing
The
DTX Series isn’t just a faster way to test. It cuts setup and reporting times.
Its ease-of-use lowers training time. Extended battery life means you can do
more on a single charge. And a bright color display, ample memory, and built-in
talk set all contribute to overall productivity while enhancing the user
experience. This all adds up to save you time and money every
day.
Enhance the power of DTX, Verify network service
availability
Improve the services you offer your customers with
the DTX CableAnalyzer and Network Service Module (DTX-NSM). Simply plug the
DTX-NSM module into the back of the main unit and you’re ready to verify network
service availability and link connectivity up to 1 Gigabit Ethernet. Verify if a
link is active, identify its data rate, duplex capabilities and whether power is
available for PoE. Then document all the network connectivity tests executed as
an integrated part of the cable certification documentation provided by
LinkWare.
Test cabling with Midspan PSEs for POE
applications
Midspan power sources block DC power from traveling
to the Ethernet switch or other active equipment in the wiring closet. This
prohibits Wiremap tests of the link with conventional DC test methods. The DTX
Series CableAnalyzer has the capability to test cabling using AC signals. This
unique feature allows full certification to ISO and TIA standards where Midspan
Power over Ethernet supplies are used.
Certify patch cord
performance
Test patch cords to ensure optimal network
performance with greater channel throughput and greater system margin. Attach
the optional DTX Patch Cord Adapters (DTX-PCU6S) to the DTX main and remote
units and you’re ready to certify patch cord performance to TIA Cat 6/5e
specifications and also ISO class D/E.
Test coaxial cable quickly
and easily
Extend the capabilities of your DTX CableAnalyzer to
test coaxial cabling systems including legacy data cabling (such as 10BASE-2 or
10BASE-5 Ethernet) and video distribution coaxial cabling. Test coax cable
length, propagation delay, cable (input) impedance and insertion loss as a
function of signal frequency.
Fluke Networks DTX-MFM
Fluke Networks' DTX-MFM set of
two Fiber Modules adds record-fast multimode fiber certification and fault
location to the DTX CableAnalyzer™ Series. Only Fluke Networks' DTX platform
offers optional on-board fiber modules so you'll never lose time searching for
your fiber adapter. Modules are easy to insert into the back of any DTX Series
CableAnalyzer. With a resident fiber module on board, fiber certification is
always ready when you are. Use the DTX-MFM Fiber Modules for certification of
50/125 and 62.5/125 multimode fiber. No other solution lets you switch between
copper and fiber with a touch of a button.
These modules deliver the
greatest time and cost savings. They accelerate testing through exclusive
technology and an easy-to-use interface. Press the Autotest button and you get
standards-compliant certification automatically. Test two fibers each at two
wavelengths, measure length and determine the pass or fail status -- all in
about 12 seconds. That's five times faster than other adapters. These fiber
modules let you test more fibers in less time, cutting testing costs and freeing
you up for other tasks. They can easily save more than 100 labor hours per
year.
DTX-MFM fiber modules use LED sources to ensure standards-compliant
certification of multimode fiber. Speed testing with TALK, FINDFIBER, MONITOR,
bi-directional and single fiber test features. Save, upload, manage and print
comprehensive certification reports using LinkWare PC software.
These
comprehensive Tier 1 certification solutions include loss, attenuation, length
and polarity measurements. You can validate fiber link performance and
installation quality. Measure optical loss at multiple wavelengths. And
bi-directionally test fibers at two wavelengths without swapping near- and
far-end units. Deliver Tier 1 fiber certification reports by uploading test
results to LinkWare PC software.
An integrated on-module visual fault
locator (VFL) makes troubleshooting simple link problems quick and incredibly
easy. The bright laser-driven VFL helps you locate many near-end fiber faults.
Also use it to locate fibers as well as verify continuity and polarity.
Exclusive integrated design ensures the visual fault locator is always on hand
when you need it.
Both modules incorporate 850-nm and 1300-nm LED sources
combined into a single output port, 850/1300/1310/1550-nm power meter and
integrated VFL.
Fluke Networks DTX-SFM
Fluke Networks DTX-SFM set of
two DTX Fiber Modules adds record-fast singlemode fiber certification and fault
location to the DTX CableAnalyzer™ Series. Only Fluke Networks' DTX platform
offers optional on-board fiber modules so you'll never lose time searching for
your fiber adapter. Modules are easy to insert into the back of any DTX Series
CableAnalyzer. With a resident fiber module on board, fiber certification is
always ready when you are. No other solution lets you switch between copper and
fiber with a touch of a button.
These modules deliver the greatest time
and cost savings. They accelerate testing through exclusive technology and an
easy-to-use interface. Press the Autotest button and you get standards-compliant
certification automatically. Test two fibers each at two wavelengths, measure
length and determine the pass or fail status -- all in about 12 seconds. That's
five times faster than other adapters. These modules let you test more fibers in
less time, cutting testing costs and freeing you up for other tasks. They can
easily save more than 100 labor hours per year.
DTX-SFM fiber modules use
laser sources to ensure standards-compliant certification of singlemode fiber.
Speed testing with TALK, FINDFIBER, MONITOR, bi-directional and single fiber
test features. Save, upload, manage and print comprehensive certification
reports using LinkWare PC software.
These comprehensive Tier 1
certification solutions include loss, attenuation, length and polarity
measurements. You can validate fiber link performance and installation quality.
Measure optical loss at multiple wavelengths. And bi-directionally test fibers
at two wavelengths without swapping near- and far-end units. Deliver Tier 1
fiber certification reports by uploading test results to LinkWare PC
software.
An integrated on-module visual fault locator (VFL) makes
troubleshooting simple link problems quick and incredibly easy. The bright
laser-driven VFL helps you locate many near-end fiber faults. Also use it to
locate fibers as well as verify continuity and polarity. Exclusive integrated
design ensures the visual fault locator is always on hand when you need
it.
Both modules incorporate 1310-nm and 1550-nm laser sources combined
into a single output port, 850/1300/1310/1550-nm power meter and integrated
VFL.
Fluke DTX-OTDR Module
The DTX Compact OTDR is a full featured Optical Time Domain Reflectometer
(OTDR) module that snaps onto the Fluke Networks DTX CableAnalyzer. It makes the
DTX powerful certification tool a complete, easy-to-use OTDR that shoots and
analyzes traces on singlemode and multimode fiber.
The DTX Compact OTDR module makes every technician a fiber expert with
unparalleled ease of use, automatic OTDR settings, loss limits for events and
fiber links, launch fiber compensation, automatic event analysis, and results
management - all with the familiar user interface of the DTX CableAnalyzer.
The DTX Compact OTDR Module leverages a contractor's investment in the DTX
CableAnalyzer by:
- Expanding installation revenue without expanding staff
- Shortening the technicians' learning curve for fiber testing
- Performing Basic (Tier 1) and Extended (Tier 2) fiber certification with a
single tool
- Accelerating troubleshooting with a powerful, single-ended OTDR
- Delivering integrated copper and fiber reports using LinkWare™
- Results Management Software
Specifications
| Key Specifications - DTX with OTDR |
| Dimensions |
Mainframe with Compact OTDR installed: 21.6 cm x
11.2 cm x 9.1 cm (8.5 in x 4.4 in x 3.6 in) nominal |
| Weight |
Mainframe with DTX Compact OTDR installed: 1.36 kg
(3 lbs) |
| Display size |
9.4 cm (3.7 in) diagonal, 240 dots wide by 320
dots high, passive color, transmissive LCD with backlight. |
| Case |
High-impact plastic with shock absorbing over mold
(mainframe) |
| Languages supported |
English, French, German, Spanish, Portuguese,
Italian, Japanese, and Simplified Chinese |
| Operating temperature |
0° C to 45° C (32° F to 113° F) |
| Non-operating temperature |
Storage: -20° C to 60° C (-4° F to 140° F) |
| Relative humidity |
% RH operating without condensation: 0° C to 35° C
(32° F to 95° F): 0% to 90% 35° C to 45° C (95° F to 113° F): 0% to
70% |
| Trace file format |
LinkWare or Bellcore GR-196 V1.1 |
| Typical trace storage capability |
>200 internal, thousands on removable MMC/SD
card |
Altitude (OTDR module) |
Operating: 3000 m Storage: 12000 m |
| EMC |
EN 61326-1 |
| OTDR laser safety |
Class I CDRH, complies to EN 60825-2 |
| Battery pack |
Removable/rechargeable 7.4 V, 4000 mAh Li
Lithium-ion |
| Battery pack life |
>8 hours |
Charge time* (with tester off) |
4 hours (below 40° C) |
| Vibration |
Random, 2 g, 5-500 Hz |
| Shock |
1 meter drop test with and without module attached
to mainframe |
| Safety class |
Class I C , Class 1 CDRH complies to
EN60825-2 |
| Safety |
CSA C22.2 No. 1010.1: 1992, EN 61010-1 1st.
edition + amendments 1, 2 |
| Calibration |
Service center calibration period is one
year |
| VFL specifications (23ş C) |
Output power (into SM fiber) |
316 µw (-5 dBm) = peak power = 1.0 mw (0
dbm) |
| Operating wavelength |
650 nm nominal |
| Spectral width (RMS) |
±3 nm |
| Output modes |
Continuous wave and pulse mode (2-3 Hz blink
frequency) |
| Connector adapter |
2.5 mm universal |
| VFL laser safety |
Class II CDRH |
| Extended specifications |
Multimode |
Singlemode |
| OTDR port connector |
Cleanable ferrule, UPC polish, with removable SC
adapter |
Cleanable ferrule, UPC polish, with removable SC
adapter |
| Fiber under test |
50/125 µm or 62.5/125 µm multimode |
9/125 µm singlemode |
| Emitter type |
Laser |
Laser |
| Wavelengths |
850 ±20 nm and 1300 ±30 nm |
1310 ±30 nm and 1550 ±30 nm |
| Dynamic range |
850 nm: 24 dB with 200ns, 1300 nm: 26 dB with 1
us |
1310 nm: 26 dB with 10 us, 1550 nm: 24 dB w/ 10
us |
| Event deadzone |
850 nm: 3.7m typical, 1300 nm: 3.5 m
typical |
1310 nm: 3.5 m typical, 1550 nm: 3.5 m
typical |
| Attenuation deadzone |
850 nm: 10 meters, 1300 nm: 13 meters |
1310 nm: 10 meters, 1550 nm: 12 meters |
| Pulse widths (nominal) |
850 nm: 20ns, 40 ns, 100 ns, 300 ns. 1300 nm:
20ns, 40 ns, 100 ns, 300 ns, 1us |
1310/1550: 40 ns, 100 ns, 300 ns, 1 us, 3 us, 10
us |
| Max distance range |
850 nm: 6 km, 1300 nm: 20 km |
1310 nm: 20 km, 1550 nm: 20 km |
| Linearity |
±0.05 dB/dB |
±0.05 dB/dB |
| Loss threshold |
0.01 dB to 1.5d B (settable in .01 dB
increments) |
0.01 dB to 1.5 dB (settable in .01 dB
increments) |
| Sample resolution |
3 cm to 4 m |
3 cm to 4 m |
| Distance accuracy |
±1 m ±0.005% of distance ±50% of resolution ± IOR
error ± event location error |
±1 m ±0.005% of distance ±50% of resolution ± IOR
error ± event location error |
| Testing speed per wavelength |
Auto OTDR: <15 seconds typical Manual OTDR: 15
sec – 3 minutes |
Auto OTDR: <15 seconds typical Manual OTDR: 15
sec – 3 minutes |
| Reflectance accuracy |
±4 dB |
±4 dB |
|