The DTX Compact OTDR is a full featured Optical Time Domain Reflectometer (OTDR) module that snaps onto the Fluke Networks DTX CableAnalyzer. It makes the DTX powerful certification tool a complete, easy-to-use OTDR that shoots and analyzes traces on singlemode and multimode fiber.
The DTX Compact OTDR module makes every technician a fiber expert with unparalleled ease of use, automatic OTDR settings, loss limits for events and fiber links, launch fiber compensation, automatic event analysis, and results management - all with the familiar user interface of the DTX CableAnalyzer.
The DTX Compact OTDR Module leverages a contractor's investment in the DTX CableAnalyzer by:
- Expanding installation revenue without expanding staff
- Shortening the technicians' learning curve for fiber testing
- Performing Basic (Tier 1) and Extended (Tier 2) fiber certification with a single tool
- Accelerating troubleshooting with a powerful, single-ended OTDR
- Delivering integrated copper and fiber reports using LinkWareâ?¢
- Results Management Software
Specifications
Key Specifications - DTX with OTDR | |
Dimensions | Mainframe with Compact OTDR installed: 21.6 cm x 11.2 cm x 9.1 cm (8.5 in x 4.4 in x 3.6 in) nominal |
Weight | Mainframe with DTX Compact OTDR installed: 1.36 kg (3 lbs) |
Display size | 9.4 cm (3.7 in) diagonal, 240 dots wide by 320 dots high, passive color, transmissive LCD with backlight. |
Case | High-impact plastic with shock absorbing over mold (mainframe) |
Languages supported | English, French, German, Spanish, Portuguese, Italian, Japanese, and Simplified Chinese |
Operating temperature | 0° C to 45° C (32° F to 113° F) |
Non-operating temperature | Storage: -20° C to 60° C (-4° F to 140° F) |
Relative humidity | % RH operating without condensation: 0° C to 35° C (32° F to 95° F): 0% to 90% 35° C to 45° C (95° F to 113° F): 0% to 70% |
Trace file format | LinkWare or Bellcore GR-196 V1.1 |
Typical trace storage capability | >200 internal, thousands on removable MMC/SD card |
Altitude (OTDR module) |
Operating: 3000 m Storage: 12000 m |
EMC | EN 61326-1 |
OTDR laser safety | Class I CDRH, complies to EN 60825-2 |
Battery pack | Removable/rechargeable 7.4 V, 4000 mAh Li Lithium-ion |
Battery pack life | >8 hours |
Charge time* (with tester off) |
4 hours (below 40° C) |
Vibration | Random, 2 g, 5-500 Hz |
Shock | 1 meter drop test with and without module attached to mainframe |
Safety class | Class I C , Class 1 CDRH complies to EN60825-2 |
Safety | CSA C22.2 No. 1010.1: 1992, EN 61010-1 1st. edition + amendments 1, 2 |
Calibration | Service center calibration period is one year |
VFL specifications (23º C) | |
Output power (into SM fiber) |
316 µw (-5 dBm) = peak power = 1.0 mw (0 dbm) |
Operating wavelength | 650 nm nominal |
Spectral width (RMS) | ±3 nm |
Output modes | Continuous wave and pulse mode (2-3 Hz blink frequency) |
Connector adapter | 2.5 mm universal |
VFL laser safety | Class II CDRH |
Extended specifications | Multimode | Singlemode |
OTDR port connector | Cleanable ferrule, UPC polish, with removable SC adapter | Cleanable ferrule, UPC polish, with removable SC adapter |
Fiber under test | 50/125 µm or 62.5/125 µm multimode | 9/125 µm singlemode |
Emitter type | Laser | Laser |
Wavelengths | 850 ±20 nm and 1300 ±30 nm | 1310 ±30 nm and 1550 ±30 nm |
Dynamic range | 850 nm: 24 dB with 200ns, 1300 nm: 26 dB with 1 us | 1310 nm: 26 dB with 10 us, 1550 nm: 24 dB w/ 10 us |
Event deadzone | 850 nm: 3.7m typical, 1300 nm: 3.5 m typical | 1310 nm: 3.5 m typical, 1550 nm: 3.5 m typical |
Attenuation deadzone | 850 nm: 10 meters, 1300 nm: 13 meters | 1310 nm: 10 meters, 1550 nm: 12 meters |
Pulse widths (nominal) | 850 nm: 20ns, 40 ns, 100 ns, 300 ns. 1300 nm: 20ns, 40 ns, 100 ns, 300 ns, 1us | 1310/1550: 40 ns, 100 ns, 300 ns, 1 us, 3 us, 10 us |
Max distance range | 850 nm: 6 km, 1300 nm: 20 km | 1310 nm: 20 km, 1550 nm: 20 km |
Linearity | ±0.05 dB/dB | ±0.05 dB/dB |
Loss threshold | 0.01 dB to 1.5d B (settable in .01 dB increments) | 0.01 dB to 1.5 dB (settable in .01 dB increments) |
Sample resolution | 3 cm to 4 m | 3 cm to 4 m |
Distance accuracy | ±1 m ±0.005% of distance ±50% of resolution ± IOR error ± event location error | ±1 m ±0.005% of distance ±50% of resolution ± IOR error ± event location error |
Testing speed per wavelength | Auto OTDR: <15 seconds typical Manual OTDR: 15 sec â?? 3 minutes | Auto OTDR: <15 seconds typical Manual OTDR: 15 sec â?? 3 minutes |
Reflectance accuracy | ±4 dB | ±4 dB |
For full Fluke Networks DTX-QUAD-OTDR product specifications, please click here: Fluke Networks DTX-QUAD-OTDR
Fluke Networks DTX-QUAD-OTDR Singlemode 1310/1550nm & Multimode 850/1300nm OTDR Module With VFL
This Module Will Allow You To Perform Singlemode 1310/1550nm & Multimode 850/1300nm OTDR Testing w/ Your DTX-1800 Cable Analyzer
This Sale Is For The OTDR Module Only. DTX-1800 Not Included!
Dynamic Range:
850 / 1300 nm : 24 / 26 dB
1310 / 1550 nm : 26 / 24 dB
Includes Carrying Case & Accessories As Listed
DTX-OTDR DTX OTDR
Fluke Networks DTX-QUAD-OTDR DTXQUADOTDR SM MM Fiber OTDR Module Models On Sale Warranty Calibration Backed by The Best Service and Lowest Prices in the Industry.
BC# 44060-L/T*
- Fluke Networks DTX-QUAD-OTDR SM MM OTDR Module (BC# 44060-L/T*)
- SM OTDR Source:
- 1310nm
- 1550nm
- MM OTDR Source:
- 850nm
- 1300nm
- VFL
- SM OTDR Source:
- (2) Fluke Networks SM Launch Cable SC-SC
- (2) Fluke Networks MM Launch Cable SC-SC
- User Manual On CD-ROM
- Carrying Case (G)