Fluke FiberLight FiberEye kit with accessories

Fluke Microtest FiberLight FiberEye MM Test Kit

Siecor OS-850V optical source with fiber cables

Siecor Corning OS-850V Optical Light Source 850nm

Fluke Networks FTK-300 SimpliFiber MM Test Kit

$0.00
Availability: Out of stock
SKU
4H23

Condition: Refurbished

Warranty: 90 Day Exchange

Request a Quote for

Have Questions or doubts? Submit the following request and expect our detailed quote within 24 hours!

we are commited to win your business!

 Fluke Networks FTK-300 Multimode Verification Kit

Verify optical loss and power levels
SimpliFiber Power Meter is calibrated for accuracy at 850 nm, 1300 nm, 1310 nm and 1550 nm. The meter features the ability to save a reference power level, allowing a direct display of fiber loss. It has an intuitive four-button panel, a large LCD display screen and a serial port to upload test results to a PC running LinkWare. SimpliFiber Sources include a dual wavelength SimpliFiber 850/1300 nm Source and separate 1310 nm and 1550 nm SimpliFiber Source. The 1310 Source features a 1310 nm laser.

Ensure smooth, clean fiber connections
Inspect the ends of fiber optic connectors with Fluke Networksメ handheld Fiber Viewer microscopes. Fiber Viewers ensure your termination is smooth, clean and ready for optical transmission. The FT120 200x Fiber Viewer is used to inspect multimode fiber end-faces. The Fiber Viewer contains a special safety filter to minimize risk of eye exposure to harmful infrared rays.

Verify and locate faults
Diagnose and repair simple fiber link problems with Fluke Networksメ VisiFaultル Visual Fault Locator (VFL). The laser-powered VisiFault locates fibers, verifies continuity and polarity, and helps find breaks in cables, connectors and splices. Continuous and flashing modes make for easier identification. Compatible with 2.5mm and 1.25mm (with optional adapter) connectors for easy connection.

Reporting made simple
Manage test results, print professional reports or export data into popular spread sheet formats. Both SimpliFiber and CableIQ store test results in memory. SimpiFiber stores up to 100 test results which can be uploaded to your PC using LinkWare Software that comes free with your SimpliFiber. For CableIQ use the included CableIQ Reporter Software.

Multimode Fiber Verification Kit
Choose this option if you are a contractor or network technician who installs and maintains multimode premise networks. Use this kit to verify optical loss and power levels at 850 nm and 1300 nm, inspect fiber endfaces and locate cable faults, connector problems and polarity issues.

Features:
  • Verify loss and power levels for multimode fiber links
  • Ensure smooth, clean fiber connector endfaces
  • Locate cable faults, connector problems and polarity issues
  • Count on tools that are field tough and user-friendly
  • Convenient carrying case provides protection and easy transport 
  • Ensure you have the tools you need when you need them
Specifications:
 
Simplifiber Optical Power Meter
Detector Type InGaAs
Calibrated Wavelengths 850 nm, 1300 nm, 1310 nm, 1490 nm, 1550 nm, 1625 nm
Measurement Range +10 to -52 dBm (850 nm)
+10 to -60 dBm (1300, 1310, 1490, 1550, 1625 nm)
Power Measurement Linearity ±0.2 dB (850 nm)
±0.1 dB (1300, 1310, 1490, 1550, 1625 nm)
Power Measurement Uncertainty ±0.25 dB
Display Resolution, dB or dBm 0.01 dB
Auto Dual-Wavelength Switching Yes
Power Display Units dBm, mW, µW
Auto-Wavelength Detection Yes
Data Storage 1000 records, multiple wavelengths per record
External Interface USB, 2.0 full speed
Optical Connector Removable adapter, SC adapter as default, optional adapters include LC, ST
Display update rate 1 reading per second
Reference Individually set for each wavelength
FindFiber ID detection Yes
Power Requirement 2 AA Alkaline batteries
Battery Life > 50 Hours (typical)
Automatic Power Off 10, 20, 30 or 60 minutes (can be disabled by user)
Low Battery Warning Yes, low battery icon blinks
Size (L x W x H) 6.4 in x 3.2 in x 1.5 in (16.5 cm x 8.0.cm x 3.9 cm)
Weight 11.5 oz (325 grams)
 
Simplifiber Multimode Source
Emitter Type LED
Central Wavelength 850, 1300nm
Wavelength Accuracy 850 nm: +/-30 nm
1300 nm: +/- 20 nm
Spectral Width (FWHM) 850 nm: 50 nm (typical)
1300 nm: 135 nm (typical)
Minimum Output Power 850/1300 nm: ³  -20 dBm
Power Output Stability ±0.1 dB over 8 hours
Auto Dual-Wavelength Switching Yes. Can be enabled/disabled by user.
Optical Output Connector Fixed SC
FindFiber Code Generation Yes. Fixed at ID 1.
Modes CW, 2 kHz modulated, Auto-wavelength
Power Requirement 2 AA Alkaline batteries.
Battery Life 40 hrs (typical)
Automatic Power Off 30 minutes (can be disabled by user)
Low Battery Warning Yes, LED blinks
Size (L x W x H) 5.6 in x 3.2 in x 1.6 in (14.2 cm x 8.1 cm x 4.1cm)
Weight 1.8 oz (278 g)
 
FT120 Fiber Viewer
Magnification 200x
Fiber adapter 2.5 mm universal ferrule adapter for multimode or singlemode fibers
Power supply Three 1.5 V AAA batteries (NEDA 24A or IEC LR03). 35 hours typical use with alkaline batteries
Light source White LED (100,000 hour life)
 
VisiFault Visual Fault Locator
Fiber Compatability Multimode and Singlemode
Wavelength 650nm
Laser saftey rating Class II
Output power < 1.3 mW
Output modes Continous (steady) and flashing (2-3Hz plused)
Range 3 km multimode, 4 km singlemode
Environmental and Mechanical
Operating Temperature 0 °C to 40 °C
Storage Temperature -20 °C to 60 °C
Relative humidity 95% (10 to 35 °C)
Vibration Random, 2g, 5-500 Hz
Shock 1 m drop onto all corners and face
Altitude 3000 m
General
Dimensions 157 x 52 x 37 mm (6.2 x 2.0 x 1.3 inch)
Weight (including batteries) 0.18 kg (5.7 oz)
Adapter 2.5 mm universal
Adapter cap Tethered protective end cap
Controls On/off, continous/flashing
Battery type 2 x AA
Battery life > 80 hours in continous mode
Safety CSA C22.2 No. 1010.1 1992, EN 61010-1, CE





For full Fluke Networks FTK-300 product specifications, please click here: Fluke Networks FTK-300

Fluke Networks FTK-300 Simplifiber MultiMode 850 / 1300nm Loss Test Kit w/ VisiFault VFL & FT120 200x Fiberscope

Power Meter:
- 850nm
- 1300nm
- 1310nm
- 1550nm

Use this kit to verify optical loss and power levels at 850 nm and 1300 nm, inspect fiber endfaces and locate cable faults, connector problems and polarity issues

Includes Carrying Case & Accessories As Listed

Fluke Networks FTK-300 FTK300 MM Fiber Loss Test Kit Models On Sale Warranty Calibration Backed by The Best Service and Lowest Prices in the Industry.

BC# 25642 25643 25644 25645

  • Fluke Networks SimpliFiber MM Source (BC# 25642)
    • MM Source:
      • 850nm
      • 1300nm
  • Fluke Networks SimpliFiber Power Meter (BC# 25643)
    • Power Meter:
      • 850nm
      • 1300nm
      • 1310nm
      • 1550nm
    • SC Connector For Power Meter
  • Fluke Networks VisiFault Visual Fault Locator (BC# 25644)
  • Fluke Networks FT120 Fiber Viewer (BC# 25645)
  • (2) MM SC-SC Fiber Cables
  • (2) SC-SC Fiber Connectors
  • Linkware Version 2.71 Software
  • (4) Fiber Wipes
  • RS232 PC Interface Cable
  • User Manual On CD-ROM
  • Hard Copy User Manual
  • Carrying Case