Fluke Networks OF-500 OptiFiber OFTM-5732 OFTM-5612B SM MM OTDR
$2,495.00
Availability:
In stock
SKU
1H301
Condition: Refurbished / Calibrated
Warranty: 1 YEAR WARRANTY
Features
- Tier 2 Fiber Certification
- Powerful Diagnostics
- Auto OTDR Analysis
- Loss Length Certification
- Fiber End-face Inspection
- ChannelMap View
- Power Meter
- Results Management
- Easy-to-use Interface
- OTDR Port Check
- Multiple Languages
- Modularity and Portability
With OptiFiber, network engineers have in-house capability to:
- Perform inspection, verification, certification, troubleshooting, and documentation of fiber cabling in a single, easy tool
- Save time and money when diagnosing fiber cabling problems that are causing network performance issues
- Easily locate and eliminate fiber problems
- Check the work of subcontractors
General OptiFiber Specifications | |
Weight | Main with module and battery: 4.5 lb (1.9 kg) |
Dimensions | Main with module and battery: 11.4 x 7.5 x 2.5 in (29.0 x 19/1 x 6.4 cm) |
Battery | Li Ion |
Battery Life | 8 hr typical |
Connections | USB, RS-232, PS-2 keyboard, Fiber Inspector Camera |
Memory Card | SD MMC (128 MB maximum) |
Operating Temperature | O °C to 40 °C (35 °C in continuous Real Time Trace |
Key OTDR Specifications (23ºC) | Singlemode: OFTM-5732 |
Output/Input Connector | SC/UPC Removable/Cleanable |
Wavelengths | 1310 ± 25nm and 1550 ± 30nm |
Fiber Under Test | 9/125µm singlemode |
Event Deadzones | 1310/1550nm: 1m typical |
Attenuation Deadzone | 1310/1550nm: 8m typical |
Pulse Width | 1310/1550 nm: 5ns, 20ns, 40ns, 100ns, 300ns, 1us, 3us, 10us |
Max Distance Range | 1310nm/1550nm: 60km |
Dynamic Range | 1310 nm: >26 dB 1550 nm: >24 dB |
Testing Speed for MultiMode Modules | Auto OTDR 15 seconds Typical Manual OTDR 15 seconds to 3 min |
Output Power | 1310nm >28mW-pk 1550nm >24mW-pk |
Distance Accuracy | |
Loss Threshold | .01 dB to 1.5 dB inclusive |
Linearity | +-.05dB/dB |
Sample Spacing | 3cm to 400cm |
Reflectance Accuracy | +- 4dB |
ORL Accuracy | +- 4dB |
Key OTDR Specifications (23ºC) for OFTM-5612B | |
Output/Input Connector | SC/UPC/Removeable/Cleanable |
Wavelengths | 850 ± 20nm and 1300 ± 20nm |
Fiber Under Test | 50/125µm or 62.5/125µm multimode |
Event Deadzones | 850nm: 0.5m typical 1300nm: 1.3m typical |
Attenuation Deadzone | 850nm: 4.5m typical 1300nm: 10.5m typical |
Pulse Width | 850 nm: 4 ns, 20 ns 1300 nm: 8 ns, 40 ns, 100 ns, 200 ns, 400 ns, 650 ns |
Max Distance Range | 850nm: 3 km 1300nm: 7 km |
Dynamic Range | 850 nm: >15 dB 1300 nm: >14 dB |
Testing Speed for MultiMode Modules | <10s for two wavelengths at 2 km with 25 cm resolution <30s for two wavelengths at 400 m with 3 cm resolution |
Output Power | 850nm >110mW-pk 1300 >22mW-pk |
Distance Accuracy | +- 1m +- 0.005% of distance+-50% of resolution +-IOR error +-event location |
Loss Threshold | .2dB |
Linearity | +- .07dB/dB |
Sample Spacing | 3cm to 50cm |
Reflectance Accuracy | +- 4dB |
ORL Accuracy | +- 4dB |
Fluke Networks OF-500 OptiFiber MainFrame With OFTM-5732 Singlemode 1310/1550nm OTDR Module With Power Meter & VFL And OFTM-5612B Multimode 850/1300nm Loss/Length Certification OTDR Module
Dynamic Range
1310 / 1550 nm : 26 / 24 dB
850 / 1300 nm : 15 / 14 dB
Power Meter
- 850nm
- 1300nm
- 1310nm
- 1550nm
Includes Carrying Case & Accessories As Listed
OF-500 OFTM OFTM 5612 OFTM5732 OFTM 5732
Fluke OF-500 OFTM-5612B OFTM-5732 OF 500 OFTM 5612B OFTM 5732 OTDR Models On Sale Warranty Calibration Backed by The Best Service and Lowest Prices in the Industry.
BC# 31254 31256 31257
- Fluke Networks OptiFiber Mainframe (BC# 46320)
- Fluke Networks OFTM-5732 SM OTDR Module (BC# 46322)
- SM OTDR Source:
- 1310nm
- 1550nm
- Power Meter:
- 850nm
- 1300nm
- 1310nm
- 1550nm
- Visual Fault Locator
- SM OTDR Source:
- Fluke Networks OFTM-5612B MM OTDR Module (BC# 46321)
- MM OTDR Source:
- 850nm
- 1300nm
- Power Meter:
- 850nm
- 1300nm
- 1310nm
- 1550nm
- MM OTDR Source:
- (2) SC Connectors For Source
- (2) SC Connectors For Power Meter
- 64MB SD Card
- (2) SM SC-SC Fiber Cables
- (2) MM SC-SC Fiber Cables
- Linkware Software Version 2.6
- Fluke Networks Optifiber Smart Remote Options CD
- Fluke Networks Certifying OTDR CD
- AC Adapter/Charger
- Power Cord
- USB PC Interface Cable
- Hard Copy user manual
- Carrying Case (G)
Request a Quote for