Fluke Networks TiR32 Building Diagnostic Thermal Imager
The greatest technological advancement in thermography may be how Fluke has made it so simple to capture images and analyze data right out of the box.
When You Need to See the Most Subtle Temperature Differences from Short or Long Distances
We know you work long hours in the field. That’s why we built this camera tough, so you can quickly and easily move from job to job. The TiR32 can save you time and money by allowing you to quickly identify building application problems and cut energy waste. Combining powerful 320 x 240 resolution with IR-Fusion® Technology, the blending of digital and infrared images into a single image, the TIR32 delivers strikingly crisp detailed images, making problem detection extremely easy. The TiR32 also produces partially transparent images that help you identify issues and report findings easier (AutoBlend™).
A Precision Instrument for Advanced Infrared Camera Trouble Shooting A Precision Instrument for Advanced Infrared Camera Trouble Shooting
With thermal sensitivity of ≤ 0.04°C at 30°C (40 mK) and temperature ranges from -20°C to 150°C (-4°F to 302°F) the TiR32 is ideal for all building applications including energy audits, weatherization and restoration. Field installable telephoto and wide angle lenses are available for added versatility for special applications and voice annotation makes pen and paper no longer necessary.
Superior image quality
Industry-leading thermal sensitivity and spatial resolution combined with a high definition display, creates the sharpest images in the industry.
One-handed, easy-to-use interface
With just a push of your thumb, go from one-handed manual smart focus to adding picture-in-picture and even add voice comments.
Torture tested™
Before a Fluke goes into your hands, we drop it from ours. Only Fluke thermal imagers are designed from the inside out to withstand a 6.5 ft drop.
Patented Fluke IR-Fusion®
(Picture-in-picture and auto blending) Precision visible and IR image alignment allows Fluke to offer the only on-camera blended infrared and visible image to better diagnose issues.
Interchangeable lenses
Interchangeable wide-angle and IR-Fusion compatible telephoto lenses to cover any application.
Features:
- Delivers the clear, crisp images needed to find problems fast with its 320 x 240 sensor.
- Identify even the smallest temperature differences that could indicate problems with thermal sensitivity (NETD)
- Automatic alignment (parallax correction) of visual and infrared images with Fluke patented IR-Fusion®
- Field replaceable batteries give you maximum flexibility no matter where your work takes you.
- Intuitive, three-button menu is easy to use—simply navigate with the push of a thumb.
- No need to carry pen and paper—record findings by speaking into the imager. Voice annotations can be recorded with every image you take. Voice comments are saved along with individual images for future reference
- One-handed focus capability, emissivity correction, reflected background temperature compensation, and transmission correction increase the accuracy of measurements in most situations.
- Adjustable hand strap for left-or right-handed use.
Specifications:
Temperature | |
Temperature measurement range (not calibrated below -10 °C) |
-20 °C to +150 °C (-4 °F to +302 °F) |
Temperature measurement accuracy | ± 2 °C or 2 % (at 25 °C nominal, whichever is greater) |
On-screen emissivity correction | Yes |
On-screen reflected background temperature compensation |
Yes |
On-screen transmission correction | Yes |
Imaging performance | |
Image capture frequency | 9 Hz refresh rate or 60 Hz refresh rate depending upon model variation |
Detector type | Focal Plane Array, uncooled microbolometer, 320 x 240 pixels |
Thermal sensitivity (NETD) | ≤ 0.04 °C at 30 °C target temp. (40 mK) |
Total pixels | 76,800 |
Infrared spectral band | 7.5 µm to 14 µm (long wave) |
Visual (visible light) camera | Industrial performance 2.0 megapixel |
Minimum focus distance | 45 cm (approx. 18 in) |
Standard infrared lens type | |
Field of view | 23 ° x 17 ° |
Spatial resolution (IFOV) | 1.25 mRad |
Minimum focus distance | 15 cm (approx. 6 in) |
Focus mechanism | Manual, one-handed Smart Focus capability |
Image presentation | |
Palettes | |
Standard | Ironbow, Blue-Red, High Contrast, Amber, Amber Inverted, Hot Metal, Grayscale, Grayscale Inverted |
Ultra Contrast™ | Ironbow Ultra, Blue-Red Ultra, High Contrast Ultra, Amber Ultra, Amber Inverted Ultra, Hot Metal Ultra, Grayscale Ultra, Grayscale Inverted Ultra |
Level and span | Smooth auto-scaling and manual scaling of level and span |
Fast auto toggle between manual and auto modes | Yes |
Fast auto-rescale in manual mode | Yes |
Minimum span (in manual mode) | 2.0 °C (3.6 °F) |
Minimum span (in auto mode) | 3.0 °C (5.4 °F) |
IR-Fusion® information | |
Automatically aligned (parallax corrected) visual and IR blending |
Yes |
Picture-In-Picture (PIP) | Three levels of on-screen IR blending displayed in center of LCD |
Full screen infrared | Three levels of on-screen IR blending displayed on LCD |
Color alarms (temperature alarms) | Dewpoint temperature alarm (user-selectable) |
Voice annotation | 60 seconds maximum recording time per image; reviewable playback on imager |
Image capture and data storage | |
The TiR32, TiR29 and Ti27 allows the user to adjust palette, blending, level, span, IR-Fusion® mode, emissivity, and reflected background temperature compensation, and transmission correction on a captured image before it is stored. |
|
Image capture, review, save mechanism | One-handed image capture, review, and save capability |
Storage medium | SD Memory Card (2 GB memory card will store at least 1200 fully radiometric (.is2) IR and linked visual images each with 60 seconds voice annotations, or 3000 basic bitmap (.bmp) images, or 3000 jpeg (.jpeg) images; transferrable to PC via included multi-format USB card reader |
File formats | Non-radiometric (.bmp) or (.jpeg) or fully-radiometric (.is2) |
No analysis software required for non-radiometric (.bmp and .jpeg) files | |
Export file formats w/SmartView® software | BMP, DIB, GIF, JPE, JFIF, JPEG, JPG, PNG, TIF, and TIFF |
Memory review | Thumbnail view navigation and review selection |
Operating temperature | -10 °C to +50 °C (14 °F to 122 °F) |
Storage temperature | -20 °C to +50 °C (-4 °F to 122 °F) without batteries |
Relative humidity | 10 % to 95 % non-condensing |
Display | 9.1 cm (3.7 in) diagonal landscape color VGA (640 x 480) LCD with backlight and clear protective cover |
Controls and adjustments | User selectable temperature scale (°C/°F) Language selection Time/Date set Emissivity selection Reflected background temperature compensation Transmission correction User selectable hot spot and cold spot, and center point on the image (other custom markers and shapes in SmartView® software) Dewpoint temperature alarm User selectable backlight: “Full Bright” or “Auto” Information display preference |
Software | SmartView® full analysis and reporting software |
Batteries | Two lithium ion rechargeable smart battery packs with five-segment LED display to show charge level |
Battery life | Four+ hours continuous use per battery pack (assumes 50 % brightness of LCD) |
Battery charge time | 2.5 hours to full charge |
AC battery charging | Two-bay ac battery charger (110 V ac to 220 V ac, 50/60 Hz) |
AC operation | AC operation with included power supply (110 V ac to 220 V ac, 50/60 Hz) |
Power saving | Sleep mode activated after five minutes of inactivity, automatic power off after 30 minutes of inactivity |
Safety standards | CSA (US and CAN): C22.2 No. 61010-1-04, UL: UL STD 61010-1 (2nd Edition), ISA: 82.02.01 |
Electromagnetic compatibility | Meets all applicable requirements in EN61326-1:2006 |
C Tick | IEC/EN 61326-1 |
US FCC | CFR 47, Part 15 Class B |
Vibration | 0.03 g2/Hz (3.8 grms), IEC 68-2-6 |
Shock | 25 g, IEC 68-2-29 |
Drop | 2 meter (6.5 feet) with standard lens |
Size (H x W x L) | 27.7 cm x 12.2 cm x 17.0 cm (10.9 in x 4.8 in x 6.7 in) |
Weight (battery included) | 1.05 kg (2.3 lb) |
Enclosure rating | IP54 (protected against dust, limited ingress; protection against water spray from all directions) |
Supported Languages | Czech, English, Finnish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, and Turkish |
For full Fluke TiR32 product specifications, please click here: Fluke TiR32
Fluke TiR32 60Hz Building Diagnostic Infrared Thermal Imager
The TiR32 is ideal for all building applications including energy audits, weatherization and restoration
60Hz With a Focal Plane Array Of 320 x 240
Temperature Range: -20 °C to +150 °C (-4 °F to +302 °F)
Includes Carrying Cases & Accessories As Listed
Fluke TiR32 TiR 32 Thermal Imager Models On Sale Warranty Calibration Backed by The Best Service and Lowest Prices in the Industry.
BC# 33676-L/T*
- Fluke TiR32 Building Diagnostic Thermal Imager (BC# 33676-L/T*)
- Fluke TiSBC3B Battery Charger
- Fluke To Delkin USB Card Reader
- Kingston Micro SD Adapter w/ 4GB SD Card
- (2) Battery Packs
- AC Adapter/Charger
- User Manual on CD-ROM
- Hard Copy User manual
- Hard Carrying Case
- Carrying Case w/ Strap