Fluke i430-Flexi-TF
Introducing the i430-Flexi-TF
The i430-Flexi-TF is a flexible AC current probe for use with the Fluke 430 series Power Quality Analyzers including Series II. The i430-Flexi-TF is optimized for current measurement on thick and hard to reach conductors.
Instrument Compatibility
The i430-Flexi-TF can only be used with the Fluke 433/434/435/437 including Series II Power Quality Analyzers.
Maintenance
Before each use, assure continued safety by inspecting the flexible probe and its latching system for any damage. Pay particular attention to the insulation surrounding the flexible probe. An i430- Flexi-TF under warranty will be promptly repaired or replaced (at Fluke's discretion) and returned at no charge.
Cleaning and Storage
• The flexible probe and its latching system require no special care. Ensure that no foreign body obstructs the latching mechanism.
• Clean the i430-Flexi-TF with a damp cloth and a mild detergent. Do not use abrasives, solvents, or alcohol.
Specifications:
For full Fluke i430 Flexi-TF product specifications, please click here: Fluke i430 Flexi-TF
Introducing the i430-Flexi-TF
The i430-Flexi-TF is a flexible AC current probe for use with the Fluke 430 series Power Quality Analyzers including Series II. The i430-Flexi-TF is optimized for current measurement on thick and hard to reach conductors.
Instrument Compatibility
The i430-Flexi-TF can only be used with the Fluke 433/434/435/437 including Series II Power Quality Analyzers.
Maintenance
Before each use, assure continued safety by inspecting the flexible probe and its latching system for any damage. Pay particular attention to the insulation surrounding the flexible probe. An i430- Flexi-TF under warranty will be promptly repaired or replaced (at Fluke's discretion) and returned at no charge.
Cleaning and Storage
• The flexible probe and its latching system require no special care. Ensure that no foreign body obstructs the latching mechanism.
• Clean the i430-Flexi-TF with a damp cloth and a mild detergent. Do not use abrasives, solvents, or alcohol.
Specifications:
SAFETY | |
The i430-Flexi-TF complies with: | CAN/CSA-C22.2 No. 61010-1-04ANSI / UL 61010-1:2004EN / IEC 61010-1:2001EN / IEC 61010-2-032:2002EN / IEC 61010-031:2002+A1:2008 |
ELECTRICAL SPECIFICATIONS | |
Measuring range | 0.5 to 6000 A ac |
Maximum non-destructive current | 100 kA (50/60 Hz |
Output signal | 86.6 mV at 1000A/50Hz (on 1 M?) 85.0 mV at 1000A/50Hz (on 50 k?) |
Basic accuracy | ±1% of reading at 25 °C, 50 Hz |
Linearity | ±0.2% of reading at 10%...100% of range |
Noise | < 1 mV rms at 10 Hz …10 kHz |
Additional errors: ? temperature coefficient over operating temperature range ? with position of conductor in the probe window (see figure 1): A = 12.7 mm (0.5 in) B = 20.3 mm (0.8 in) C = 35.6 mm (1.4 in) ? 0.5 to 30 A |
0.05% of reading /°C, 0.09% of reading /°F ±0.5% of reading ±1.0% of reading ±2.0% of reading ±1 count or 0.1 A (whichever is greater) |
External magnetic field rejection in reference to external current | 40 dB (with cable >100mm from the head coupling and r-coil) |
Phase shift (fundamental frequency) | < ±1° |
Bandwidth (-3dB) | 10 Hz to 10 kHz |
Frequency derating | I x f ≤385 kA Hz |
Working voltage | 1000V CAT III, 600V CAT IV |
GENERAL SPECIFICATIONS | |
Weight | 195 g |
Transducer length | 610 mm (24 in) |
Transducer diameter | 7.5 mm (0.3 in) |
Minimum bending radius | 38 mm (1.5 in) |
Cable length from transducer to BNC | 2.5 m (98.4 in) |
Temperature, operating | -20 to +70°C (-4 to +158°F) Temperature of conductor under test shall not exceed 80°C (176°F) |
Temperature, non-operating | -40 to + 80°C (-40 to +176°F) |
Relative Humidity, operating | 15 to 85%, non condensing |
Altitude, operating | 3000 m |
For full Fluke i430 Flexi-TF product specifications, please click here: Fluke i430 Flexi-TF
Set of 4 Fluke i430 FLEXI-TF AC Current Probes
The i430-Flexi-TF can only be used with the Fluke 433/434/435/437 including Series II Power Quality Analyzers.
The i430-Flexi-TF is optimized for current measurement on thick and hard to reach conductors.
i430FlexiTF i430 Flexi TF
Fluke i430 Flexi-TF i 430 Flexi-TF AC Current Probe Models On Sale Warranty Calibration Backed by The Best Service and Lowest Prices in the Industry.
BC# 23195M-L/T*
- (4) Fluke i430 FLEXI-TF AC Current Probes w/ Instructions (BC# 23195M-L/T*)
Request a Quote for