Furukawa FiTel Fusion Splicer S-174H
A high-precision fusion splicer for singlemode fiber and multimode fiber. The
core of each fiber is viewed dirctly ensuring accurate alignment of fibers. The
lightweight, compact design makes the splicer easily transport for field
use.
Key Features
- The S174H automatically measures the core/clad offset, aligns and splices
the fibers, and then estimates the splice loss.
- The TV monitor displays operational information and the fusion splice
process.
- Splicing parameters for 30 types of fibers can be stored.
- Data from a hundread splices can be stored in memory.
- A heater with an air-cooling fan is built in . This reduces the splice
reinforcement time, compared with conventional product.
- A short exess length is required for splicing due to the heater location.
- An electrical discharging circuit with sophisticated correction ensures
stable fusion splicing even in high altitudes.
Applicable fibers
- Multi-mode fiber 50/125, 62.5/125
- Single-mode fiber 10/125
- Material type: Silica glass
- Coating diameter: 0.25 to 1.00 mm
Splice loss
- SM fiber 10/125 (identical)*: Average 0.04 dB
- MM fiber (identical)*: Average 0.03 dB
Output terminals
- Data communications: RS-232C DIN 8-pin jack
- Video: BNC-type jack
Input power
- 85 to 246 VAC, 50/60Hz,
- 10 to 15 VDC
- 100 W
Size
- Body: 200mm (W)x190mm (D)x180mm (H)
- Case: 420mm (W)x316mm (D)x350mm (H)
Weight
- Body: 7.9 Kg
- Case: 4.3 Kg
HP E6000B OTDR Mainfame
The Agilent/HP E6000B Mainframe maximizes your network uptime by locating and
characterizing faults quickly and accurately.
The combination of 16,000 data points and a minimum sample spacing of 8cm
allows the powerful analysis algorithm to determine the exact location and
characteristic of an event.
The Agilent/HP E6000B OTDR repeatedly outputs an optical pulse into the
connected fiber and measures the reflections from this pulse. The trace
displayed on the screen is a graph of this reflected power (backscatter) as a
function of the distance along the fiber.
Events are changes in the fiber causing the trace to deviate from a straight
line. Events can be Reflective or Non-Reflective.
Reflective Events occur when some of the pulse energy is reflected, for
example at a connector. Non-Reflective Events occur at parts of the fiber where
there is some loss but no light is reflected. Non-Reflective Events produce a
dip on the trace.
The E6000B OTDR calculates the distance of such an "event" in the fiber from
the time it takes the reflected signal to return. The further away an event is,
the longer it takes for its reflection to return to the E6000B OTDR.
A fully automatic function is available and the E6000B OTDR sets itself up to
achieve the best results for the measurements such as the location (distance) of
events on the link, the end of the link or a break, the attenuation coefficient
of the fiber in the link, the loss of an individual event or the total
end-to-end loss of the link, the magnitude of the reflection (or reflectance) of
an event, such as a connector, the cumulative loss to an event can be measured
automatically.
The Agilent E6000B can operate through the supplied AC adapter between 100V
and 240V ±10%, at a frequency in the range from 50 to 60 Hz. The maximum power
consumption is 30VA with all options installed.
The Agilent E6000B can operate from a DC power source that supplies between
16V and 24V. The maximum power consumption during a quick charge is 30W with all
options installed. Typical power consumption is below 8W.
Key Points:
- Built in Applications
- Built in multi fiber test
- With template mode
- One button operation
- Automatic event adjustment
- 15 secs power up cycle
- Automatic fiber characteristic
| Brand |
Agilent / HP |
| Model |
E6000B |
| Description |
Mini OTDR Mainframe |
| Category |
OTDR |
| Sub Category |
N/A |
| Specifications: |
| User Interface |
Proprietary |
| Input Power |
Universal |
| Inter memory |
Up to 200 traces |
| Operating Temperature |
0 to 50 deg C |
| Storage Temperature |
-40 to 60 deg C |
| Dimensions |
194 mm H, 290 mm W, 75 mm D (7.7" x 11.4" x 3.0") |
| Weight |
net < 2.9 kg (6.4 lbs) |
E6003A Specifications:
| Wavelength |
1310/1550nm |
| Dynamic Range (dB) |
35/34dB |
| Event Deadline |
3m |
| Attenuation Dead Zone |
10/12m |
| Recommended Application |
Metropolitan/Trunk |
| Fiber Type |
Single-Mode |
| Module |
E6003A |
E6007A
Characteristics
Source type: Laser diode
Center Wavelength: 635 nm ± 10 nm (visible red light)
Output power level (CW)
- 0 dBm maximum
- into 9µm fiber (typ.): -3 dBm
Detection range: up to 5 km
Optical output: User-exchangeable Connector Interface
Laser Class II (21 CFR 1040), Class II (IEC 825-1)
Supplementary Performance Characteristics
- Continuous Wave and Blink Mode(1 Hz for better visibility).
- Single-Mode and multimode fibers applicable.
General Specifications:
Dimensions: ca. 120 mm H x 40 mm W x 25 mm D (4.7? x 1.6? x
1.0?)
Weight: < 100g
Operating Temperature: 0 to 40 °C
Storage Temperature: -40 to +60 °C
Humidity: 95% R.H. from 0°C to 40°C non cond
|