Authorize.Net Secure Checkout   Buy Now Pay Later  
Fusion Splicer OTDR Kits
 
 
 
 
 
Smart Phone Users
Scan Here To Bookmark This Page
 
 

2D52 - FiTel S-174H Fusion Splicer & HP E6000B SM OTDR

FiTel S174H Core Alignment Fiber Fusion Splicer with Fujikura CT-04 Fiber Cleaver
&
HP Agilent E6000 B Mini-OTDR With E6003A Singlemode 1310nm/1550nm & E6007A VFL Modules
Dynamic Range:
1310/1550 nm : 35/34 dB
Includes Fujikura CT-04 Fiber Cleaver, Carrying Cases & Accessories As Listed!



Price: Contact Sales


 
 
 
Condition Refurbished / Calibrated
Warranty 90 Day Exchange
Included
  • FiTel S-174H Fiber Optic Fusion Splicer 
  • Fujikura CT-04 Fiber Cleaver
  • (20) Fiber Protection Sleeves
  • Working Tray
  • Clauss Fiber Optic Stripper
  • Power Cord
  • DC Power Cord
  • Spare Electrode Set 
  • Hard Copy User Manual
  • Hard Carrying Case

 

  • HP E6000B OTDR Mainfame
  • HP E6003A SinlgeMode Module
    • 1310nm
    • 1550nm
  • HP E6007A VFL Module
  • Fiber Cables:
    • (2) SM SC-SC
  • Battery Pack
  • AC Adapter/Charger
  • Power Cord
  • RS-232 PC Interface Cable
  • User Manual On CD-ROM
  • Soft Carrying Case
 

Furukawa FiTel Fusion Splicer S-174H

A high-precision fusion splicer for singlemode fiber and multimode fiber. The core of each fiber is viewed dirctly ensuring accurate alignment of fibers. The lightweight, compact design makes the splicer easily transport for field use.

 

Key Features

  • The S174H automatically measures the core/clad offset, aligns and splices the fibers, and then estimates the splice loss.
  • The TV monitor displays operational information and the fusion splice process.
  • Splicing parameters for 30 types of fibers can be stored.
  • Data from a hundread splices can be stored in memory.
  • A heater with an air-cooling fan is built in . This reduces the splice reinforcement time, compared with conventional product.
  • A short exess length is required for splicing due to the heater location.
  • An electrical discharging circuit with sophisticated correction ensures stable fusion splicing even in high altitudes.

 

Applicable fibers

  • Multi-mode fiber 50/125, 62.5/125
  • Single-mode fiber 10/125
  • Material type: Silica glass
  • Coating diameter: 0.25 to 1.00 mm

 

Splice loss

  • SM fiber 10/125 (identical)*: Average 0.04 dB
  • MM fiber (identical)*: Average 0.03 dB

 

Output terminals

  • Data communications: RS-232C DIN 8-pin jack
  • Video: BNC-type jack

 

Input power

  • 85 to 246 VAC, 50/60Hz,
  • 10 to 15 VDC
  • 100 W

 

Size

  • Body: 200mm (W)x190mm (D)x180mm (H)
  • Case: 420mm (W)x316mm (D)x350mm (H)

 

Weight

  • Body: 7.9 Kg
  • Case: 4.3 Kg

 

HP E6000B OTDR Mainfame

The Agilent/HP E6000B Mainframe maximizes your network uptime by locating and characterizing faults quickly and accurately.

The combination of 16,000 data points and a minimum sample spacing of 8cm allows the powerful analysis algorithm to determine the exact location and characteristic of an event.

The Agilent/HP E6000B OTDR repeatedly outputs an optical pulse into the connected fiber and measures the reflections from this pulse. The trace displayed on the screen is a graph of this reflected power (backscatter) as a function of the distance along the fiber.

Events are changes in the fiber causing the trace to deviate from a straight line. Events can be Reflective or Non-Reflective.

Reflective Events occur when some of the pulse energy is reflected, for example at a connector. Non-Reflective Events occur at parts of the fiber where there is some loss but no light is reflected. Non-Reflective Events produce a dip on the trace.

The E6000B OTDR calculates the distance of such an "event" in the fiber from the time it takes the reflected signal to return. The further away an event is, the longer it takes for its reflection to return to the E6000B OTDR.

A fully automatic function is available and the E6000B OTDR sets itself up to achieve the best results for the measurements such as the location (distance) of events on the link, the end of the link or a break, the attenuation coefficient of the fiber in the link, the loss of an individual event or the total end-to-end loss of the link, the magnitude of the reflection (or reflectance) of an event, such as a connector, the cumulative loss to an event can be measured automatically.

The Agilent E6000B can operate through the supplied AC adapter between 100V and 240V ±10%, at a frequency in the range from 50 to 60 Hz. The maximum power consumption is 30VA with all options installed.

The Agilent E6000B can operate from a DC power source that supplies between 16V and 24V. The maximum power consumption during a quick charge is 30W with all options installed. Typical power consumption is below 8W.

 

Key Points:

  • Built in Applications
  • Built in multi fiber test
  • With template mode
  • One button operation
  • Automatic event adjustment
  • 15 secs power up cycle
  • Automatic fiber characteristic

 

Brand Agilent / HP
Model E6000B
Description Mini OTDR Mainframe
Category OTDR
Sub Category N/A
Specifications:
User Interface Proprietary
Input Power Universal
Inter memory Up to 200 traces
Operating Temperature 0 to 50 deg C
Storage Temperature -40 to 60 deg C
Dimensions 194 mm H, 290 mm W, 75 mm D (7.7" x 11.4" x 3.0")
Weight net < 2.9 kg (6.4 lbs)

E6003A Specifications:

Wavelength 1310/1550nm
Dynamic Range (dB) 35/34dB
Event Deadline 3m
Attenuation Dead Zone 10/12m
Recommended Application Metropolitan/Trunk
Fiber Type Single-Mode
Module E6003A

 

E6007A

Characteristics

Source type: Laser diode

Center Wavelength: 635 nm ± 10 nm (visible red light)

Output power level (CW)

  • 0 dBm maximum
  • into 9µm fiber (typ.): -3 dBm

Detection range: up to 5 km

Optical output: User-exchangeable Connector Interface

Laser Class II (21 CFR 1040), Class II (IEC 825-1)

Supplementary Performance Characteristics

  • Continuous Wave and Blink Mode(1 Hz for better visibility).
  • Single-Mode and multimode fibers applicable.

General Specifications:

Dimensions: ca. 120 mm H x 40 mm W x 25 mm D (4.7? x 1.6? x 1.0?)

Weight: < 100g

Operating Temperature: 0 to 40 °C

Storage Temperature: -40 to +60 °C

Humidity: 95% R.H. from 0°C to 40°C non cond


Copyright © 2003-2011 AAATesters.com | Phone: 419-517-6681 Toll Free: 1-800-548-2381