Fujikura FSM-20RSII12 Arc Fusion Splicer
The FSM-20RSII12 ARC Fusion Splicer is used to splice optical single fiber or
fiber ribbons. The FSM-20RSII12 can splice up to 12 fiber ribbons.
This Fusion Splicer has installed a 4 inch LCD monitor and a heater for
spliced portion reinforcement. Besides, it has a built-in microprocessor to
perform image processing so that automatic fusion splicing with estimated loss
can be achieved. This Fusion Splicer can use AC100-240V 50/60Hz. (Max. 3A) or
DC12V (Max. 10A) power sources
Features
- Fiber Splicing Capabilities : SM, MM
- Splice Loss Estimation Function / Calculation Capability
- Atmosphere, humidity and temperature compensation functions
provided
- 3" LCD monitor with excellent view ability in direct sunlight
- Memory : 100 splice data sets with internal memory
- High Intensity Halogen Inspection Lamp
Fujikura FSM20RS Ribbon fusion splicer utilizes a PAS (Profile Alignment
System) that aligns the core of single-mode and the cladding of multimode
fibers. A built in monitor allows cross-sectional viewing of the prepared fiber
ends, and displays cleave angle and estimated splice loss. the system will
splice both single-mode and mult-mode fibers. Alignment, fusion and splice loss
estimation are automatically completed by the built-in computer. Applicable
fibers: SMF at 1310nm; DSF at 1550nm; GI fibers. Average splice loss: 0.03 dB
(SMF); 0.05 dB (DSF); 0.02 dB (GI). Includes a built-in tube heater for
installing splice protective sleeves. AC- or external 12 Vdc- powered.
Tektronix TFS3031 Tekranger SingleMode OTDR
TekRanger TFS3031 mini-OTDR (optical time domain reflectometer). The product
features IntelliTraceTM, a new patented technology for unprecedented accuracy
and ease of use in testing fiber optic networks. TekRanger, which replaces the
popular FiberMiniTM, adds an optional disk drive and is the first mini-OTDR with
both singlemode and multimode test capability in one instrument.
"The accelerating deployment of broadband networks is driving a need for
rugged test tools that are smaller, faster, and more intelligent," said Ken
Ditto, TekRanger product manager at Tektronix. "TekRanger answers this need in
data, cable TV and telephony applications." IntelliTrace Includes Enhanced
Acquisition and Display
IntelliTrace provides complete and accurate results by adjusting acquisition
parameters, such as pulse width and number of averages, as it automatically
analyzes a fiber link. As a result, it more accurately measures small and
closely spaced events, even over long distances. Near-in events are also
captured because of TekRanger's superior dead zone performance, allowing
one-button testing from five meters to more than 100 km.
IntelliTrace features enhanced display of acquired data, with events such as
splices and excessive bends in the cable automatically marked and viewable in
table format simultaneously with the waveform. Operators can customize the event
table, add comments, and eliminate or add events.
TekRanger also features a range of user language options, including English,
Chinese, Japanese, French, Portuguese, Spanish and German.
TekRanger is the first mini-OTDR to offer the capability to test both
singlemode and multimode fiber with the same instrument. The unique two port
design, which allows users to test multimode and singlemode fiber without having
to change modules, makes the TekRanger very durable.
Designed for Optimal Performance in the Field
Like its predecessor, the TekRanger mini-OTDR is rugged, splash-proof and
shock-resistant. It weighs only nine pounds (4.2 kg) and measures 11.25 in. x
9.5 in. x 4 in. (29.2 cm x 24.1 cm x 11.4 cm). TekRanger operates using an
internal, eight-hour NiCAD battery or standard "C"-size alkaline batteries. An
enhanced power management system includes a battery level indicator, low-battery
warning and the ability to be recharged from a vehicle.
The large, high-resolution 640 x 480 backlit display, makes waveforms and
tables easy to read, even under difficult lighting conditions. Users can easily
store up to 200 waveforms in the expanded internal memory, or use the optional,
integrated disk drive for waveform documentation and archiving. The disk drive
also allows software upgrades, enabling TekRanger to meet evolving customer
requirements.
Features & Benefits
- One-button Fully Automatic IntelliTrace Fiber Analysis
- Singlemode Distance and Loss Measurements Traceable to NIST
- Large, Backlit, High-resolution Display
- Keyboard Port and Optional Mini-keyboard
- RS-232 and Parallel Ports for Printing and PC Access
- Shock, Water and Dust Resistant
- Auto Echo Detection
- Selectable Splice Loss and Reflectance Thresholds
- Files are Compatible with FiberMaster™ OTDR, TARGET1™, PC
- Spreadsheets
- Context Sensitive Help
Applications
- Installation and Acceptance Testing of Fiber Optic Networks
- Fiber Optic System Maintenance Testing
- Locating Optical Cable Faults During Restoration
- Optical System Documentation
Wavelengths
General Specs:
- Readout Resolution: 25 cm minimum.
- Loss threshold: 0.02 dB.
- Loss resolution: 0.001 dB.
- Distance Measurements: Meters, feet, miles.
- OTDR Distance Range Settings: Singlemode: 1 to 240 km.
- Distance Resolution (IntelliTrace™): 1.25 m to 40 m.
- Hardware Scale Accuracy: *3 -
- Horizontal Time Base: ±1.25 m ±1.25 m ± 10-5 x distance.
- Vertical Linearity: 0.02 dB/dB.
- System Measurement Accuracy: *4 -
- Distance: ±4 m.
- Loss: ±0.01 dB.
- Reflectance Accuracy: Exceeds Bellcore GR-196-CORE*2.
- Measurement Time (Auto): Less than 3 minutes (20 dB loss).
- Dead Zone*2:Singlemode/ Loss: 5m, Loss Measurement: 15m
- Display: High resolution 640 x 480; 7.2 in., high contrast; operator
switchable backlight.
- Selectable Pulse Widths: 1 m, 5 m, 10 m, 20 m, 50 m, 100 m, 200 m, 500 m,
1000 m, 2000 m.
- Memory Capacity:100 traces in internal memory (typical).
- 3.5 in. floppy disk drive (optional).
- Output Ports: RS-232 serial; Centronics parallel printer, mini-DIN
(keyboard).
- Power Options: AC (100 to 240 V, 50 to 60 Hz). DC Operation: 9 to 16 VDC.
- Internal NiCad rechargeable battery (4 hours of operation depending on
operating mode).
- Laser Safety: Class 1 per 21 CFR 1040, Class 1 per CEI/IEC 825-1: 1993,
- Options 3T, 4T and 7T are Class 1,
- Option 6T is Class 2, Environmental (without internal disk drive)
- Temperature Range: Operating: -10 °C to +40 °C, Nonoperating: -20 °C to
+60 °C,
- Storage Temperature - -20 °C to +60 °C.
- Relative Humidity: 5% to 95% (noncondensing).
- Field Usage*2: Shock, water and dust resistant, Shock*2 - 30 in. drop.,
Safety - UL 3111-1, CSA 1010.1,
- Physical Characteristics:11.5in (W) x 4.5 (H) x 9.5in (D)
|