Authorize.Net Secure Checkout   Buy Now Pay Later  
OTDR's GNNettest LaserPrecision
 
 
 
 
 
Smart Phone Users
Scan Here To Bookmark This Page
 
 

2D40 - Siecor M90 5000 Fusion Splicer & PK7500 SM OTDR

Siecor Corning M90 Fusion Splicer 5000 Series
&
GN Nettest PK7500 OTDR Mainframe with 742S Singlemode 1310nm/1550nm OTDR Module With Power Meter & VFL
Dynamic Range:
1310/1550nm : 34.0/32.0dB
OTDR
1310nm
1550nm
Power Meter
1310nm
1550nm
Includes Siecor FBC-005 Fiber Cleaver, Attached Heat Shrink Oven & Overhead Work Lamp!





Price: $ 6,495.00 / Each


 
 
 
Condition Refurbished / Calibrated
Warranty 90 Day Exchange
Included
  • Siecor M90 3000 Series Fusion Splicer
  • Siecor FCB-005 Attached Fiber Cleaver
  • 250 Micron Singlemode Fiber Holder Set
  • RXS S4699-M7-S287 Attached Heat Shrink Oven
  • Clauss Fiber Optic Stripper
  • Assorted Tool Kit
  • Power Cord
  • RS232 PC Interface Cable
  • Corning FBC-005 Operating Manual
  • Hard Copy User Manual
  • Integrated Hard Case

 

  • GN Netetest PK7500 OTDR Mainframe
  • GN Nettest 742S Module
    • Singlmode
      • 1310nm
      • 1550nm
    • Power Meter
      • 1310nm
      • 1550nm
    • VFL
  • Interchangeable FC Connector For Meter
  • (2) SM FC-FC Fiber Cable
  • FC-FC Fiber Connector
  • SoftView Plus OTDR Emulation Software
  • AC Adapter/Charger
  • Power Cord
  • DC Car Charger
  • RS232 PC Interface Cable
  • User Manual On CD-ROM
  • Hard Carrying Case
 

Siecor M90 5000 Series Fusion Splicer

The microprocessor controlled fusion splicer is used for mechanically durable, low-loss fusing of optical fibers with long-term stability.

Fiber Diameters
Single-mode fibers, dispersion-shifted single-mode fibers and multimode fibers with coating diameters of up to 900 um can be fused. The splicer is designed for use with the standard 125 um outside fiber diameter (without coating). If you need to splice fibers with other diameters, please contact the manufacturer.

Automatic Fiber Positioning
Fiber positioning and the fusion process run automatically. This assures uniform high quality results independent of the operator. Two mutually independent processes for positioning and automatic splice loss determination have been integrated into the splicer. The time tested LID system (Local Injection and Detection) allows for accurate core-to-core positioning of the fiber ends such that good splicing results can even be achieved with singlemode fibers with eccentric cores. It also allows for the measurement of splice loss at an operational wavelength of 1300 nm. If the LID system cannot be used (e.g. with tight-buffered fibers), the completed splice is analyzed with the L-PAS -video system (Lens Profile Alignment System), and splice loss is indicated in dB as well.

Fiber Requirements: Single and multimode glass fiber with 125 um glass diameter, 250 to 900 um coating diameters
Fiber Display: High contrast 5.5" color LCD
Magnification: Approximately 100 power
Fiber Positioning: Fully automatic in X, Y and Z axes
Mean Splice Loss for Identical, Standard Single-Mode Fibers:
        Multimode fiber: typ. < 0.01 dB
        Standard single-mode fiber: typ. < 0.02 dB
Tensile Test: Automatic / OFF
Splicing Programs: Preset, special and user programs
Video Output: CCIR output (75 ohm)
Mains Power: 95 to 260 V with automatic voltage range selection, 50 - 60 Hz, max 100 VA
External 12 V Power Supply: 12 - 14.5 V, max. 5 A, pole reversal protected
Data Memory Capacity: 1000 splice values
Data Output: RS 232 interface with adjustable baud rate
LID System: Wavelength: 1300 nm, temperature compensated
Attenuation Splices: 1 to 10 dB (in steps of 0.1 dB)
Real-Time Clock: Time and date display with battery backup
Operating Temperature: -5° C to +45° C
Storage Temperature: -20° C to +70° C

 

PK7500 OTDR

The Model 7500 Mini-OTDR ( OPTICAL TIME DOMAIN REFECTOMETER ) offers >32dB of Dynamic range, 20 meter attenuation dead zone and 5 meter event dead zone. There is an Auto Test function and information is displayed on a 9.4-inch , VGA, LCD screen.

The Model is ideal for use in telecom , CATV, LAN, and manufacturing applications.

TELECOM
The Model 7500's dynamic range can be used for testing long trunk or interoffice fiber spans. The unit's short dead zone allows closely spaced features to be measured. Configured with the visual fault locator option, the Model 7500 will troubleshoot fiber in splice cabinets/enclosures, giving a virtual "zero" dead zone performance.

CATV
The Loss Table automatically calculates the reflectance of mechanical splices as well as the Optical Return Loss (ORL) for the fiber span. The optional OTDR emulation software for your PC allows you to analyze data and generate hard copy documentation in your office.

LAN
The Model 7500 offers single-mode and multimode plug-ins that can be used in LAN applictations where there is a need to test different types of fiber cable or composite cable. The Auto Test function allows fast, easy measurements without a skilled operator. Size, weight, and battery operation give the Model 7500 optimum portability. (includes only Single-Mode Module 742s)

MANUFACTURING
The Model 7500's dynamic range and accuracy make it convenient for quick distance measurements on the production floor. Attenuation and lenght of fiber may be obtained quickly by generating a Loss Table.

Specifications:
Acquisition/Distance Range (KM) 4,8,16,32,64,128,256
Distance Accuracy ±0.8 Meters ±0.01% of length measured
Distance Readout Resolution 10.0cm
Refractive Index Range 1.4000 to 1.7000
dB Linearity 0.05dB/dB
Loss Modes 2pt, LSA (dB/KM), auto or manual splice (dB), reflectance (dB), Power Meter (dB, dBm, Watts), ORL (dB)
Display 9.4" diagonal, backlit, VGA (640 x 480) LCD
Storage Internal RAM, 1.44MB 3-1/2" disk drive option
Weight 3.2kg (7lbs)
Dimensions 34.3cm x 24.1cm x 7.6cm (13.5in x 9.5in x 3.0in)
Battery Life > 6 hours (rechargeable), 180 scans
External Power 85-264VAC/47-440Hz; 10-15VDC
Interfaces RS-232C, parallel, keyboard accessory port (data entry)

742S Singlemode Module:
Center Wavelength (nm) 1310/1550 ± 20
(m)    Pulse Width     (sec) Dynamic Range
1000 10.0µs 34.0/32.0
500 5.0µs 32.5/30.5
100 1.0µs 29.0/27.0
50 500.0ns 27.5/25.5
10 100.0ns 24.0/22.0
50 50.0ns 13.0/11.0
2.5 25.0ns 11.0/9.0
1 10.0ns 9.0/7.0
Attenuation Dead Zone (m) 20.0/25.0
Event Dead Zone (m) 5.0


Copyright © 2003-2011 AAATesters.com | Phone: 419-517-6681 Toll Free: 1-800-548-2381

Find Us On FacebookFind Us On Twitter