Get through your jobs faster than ever today and prepare yourself for the future with LANTEK 6, the industry's most capable CAT 6/ISO E hybrid copper/fiber certifier, testing applications up to 350MHz, well beyond CAT 6/ISO E draft specifications.
The LANTEK 6 performs full Category 6/ISO E Autotest with graphs in approximately 25 seconds. Plus the LANTEK 6 is fully upgradeable to LANTEK 7, protecting your investment and giving you the maximum flexibility in meeting your evolving certification needs.
LANTEK 6 utilizes advanced link adapter method to reduce cost of ownership. LANTEK 6 comes with a pair of Category 6/ISO E channel adapters that fit into the case of the unit and are locked into place. This creates a stable and repeatable testing platform while eliminating bulky adapters. By simply plugging in a Category 6/ISO E reference patch cord to the channel adapter, you can now perform CAT 6/ISO E permanent link testing. Should the plug ever wear out, simply replace the patch cord rather than the entire assembly reducing lifetime ownership cost.
LANTEK 6 comes standard with all the items necessary to certify your job and create certification reports including: Display Unit (with battery); Remote Unit (with battery), LANTEK Reporter Software; Serial and USB Cables; two AC Wall Adapters; two Talksets; two CAT 6 Channel Adapters; two CAT 6 Reference Patch Cords; soft Carry Case; User Manual; Quick Start Guide; and Registration Card.
Features:
- Fully compliant with Category 6/ISO E draft standards
- Full Category 6/ISO E AutoTest with graphs in approximately 25 seconds
- Tests Cat 7/ISO F limits up to 350 MHz
- Advanced link adapter method provides more versatrility & reduces cost of ownership
- Built in TDR ready for copper and fiber
- Display unit comes with 1/4 VGA color screen, remote unit comes with two-line black and white LCD display
- Serial and USP ports for uploading tests and upgrading firmware
| FEATURES |
LANTEK 6 |
| Frequency Range |
350 MHz |
| Supports CAT7 & ISO-F |
Upgradeable |
| Supports CAT6a |
Upgradeable |
| Support CAT6/5e/3 and ISO-E/D/C |
✓ |
| Accuracy Level III/IIIe (Draft)/IV verified by |
ETL |
| Support DUALmode Testing to Save Time |
✓ |
| Test with Patchcords to Save Money |
✓ |
| Screen Display Area |
Best |
| CAT6 Test Storage with Graphs |
500 |
| Expansion Slots |
CompactFlash Card |
| Standard External Compact Flash Memory |
Option |
| USB/Serial Port |
✓ |
| Copper TDR Trace |
✓ |
| Fiber Loss Measurement (FIBERTEK) |
Option |
| Fiber Distance to Break (TRACETEK) |
Option |
| Talk over Fiber & Copper (Full Duplex) |
✓ |
| Display Screen on Remote |
✓ |
| Troubleshooting Tone Generator on Remote |
✓ |
| External Rapid Battery Charger & Extra Batteries |
Option |
Specifications:
| Internal memory |
No graphs approximately 6,000 tests |
With graphs approximately 100 tests |
| External memory 32MB compact flash |
No graphs approximately 24,000 tests |
With graphs approximately 400 tests |
| External memory 256MB compact flash |
No graphs approximately 192,000 tests |
With graphs approximately 3,200 tests |
| Standard test compliance |
ANSI/TIA/EIA 568B, Category 6 (draft), ISO C/D and ISO E/F (draft), AS/NZS
3080, IEEE 802.3
Ethernet, EN50173, EN50173A1 |
| Cable types |
UTP/ScTP/FTP
ISO C/D/E/F (Channel, Basic, and Permanent Link)
IBM STP Type 1,2,6,Coax |
| Dimensions |
10.1" x 5.0" x 2.3" Display and remote |
| Weight |
2.3 lb. Display |
2.0 lb. Remote |
1.2 lb Battery |
| Battery Packs |
NiMH rechargeable |
| Typical operating life (battery) |
8 hrs |
| Max. Operating Temp. |
32 to 122°F (0-50°C degrees) |
| Max Storage Temp. |
-4 to 158°F (-20 to +70°C degrees) |
| Humidity |
5-90% noncondensing |
| Series 6 |
Range |
Resolution |
Accuracy |
| Length (50-100Ω cable) |
0-2000ft |
1ft |
±(3% + 3ft) |
| Delay |
0-8000 ns |
1ns |
±(3% + 1ns) |
| Average Impedance |
35-180Ω |
0.1Ω |
±(3% + 1Ω) |
| Capacitance (bulk) |
0-100 nF |
1pF or 3 dig |
±(2% + 20 pF) |
| Capacitance |
0-100 pF/ft. |
0.1 pF |
±(2% + 20 pF) |
| DC Loop Resistance |
0-200Ω |
0.1Ω |
±(1% + 2Ω) |
| Noise Floor |
<-90 dB |
| Dynamic Range |
>90 dB |
|