Viavi JDSU OLP-82P SM MM Power Meter Fiber Inspection Kit

Viavi JDSU OLP-82P SM MM Power Meter Fiber Inspection Kit

Fluke Networks SimpliFiber Pro SM Fiber Optic Source

Fluke Networks SimpliFiber Pro SM Fiber Optic Source

JDSU 4138 RMP65 SM Long Haul Fiber OTDR Module 1650nm

$2,995.00
Availability: In stock
SKU
3L99

Condition: Refurbished / Calibrated

Warranty: 1 YEAR WARRANTY

JDSU 4138 RMP65 SM Fiber OTDR Module
The JDSU MP OTDR module provides the optimum performance that fiber installers and service providers need to test metro, cable TV (CATV) and FTTH networks with high-port-count splitters.

With various wavelength combinations including filtered wavelengths for in-service testing, an improved dynamic range, and optimized resolution and dead zones at short pulses, the MP module is the ideal OTDR to test any PON system with up to a 1x128 splitting ratio.

The MP module's optical performance, combined with the T-BERD/MTS platform's complete suite of features, ensures that testing is done right the first time.

Standard testing features include:
  • Automatic macrobend detection
  • Summary results table with pass/fail analysis
  • Bidirectional OTDR analysis
  • FastReport on-board report generation
Features:
  • Up to 43 dB dynamic range and 256,000 acquisition points
  • PON-optimized to test up to a 1x128 splitter
  • Single-, dual-, and tri-wavelength versions with 1310/1490/1550/1625/1650 nm
  • Single connector port for 1310, 1550, and inservice 1625 nm or 1650 nm wavelengths
  • Integrated CW light source and power meter
  • FiberComplete™ compatible
  • Ready for SLM, FTTA-SLM, and FTTH-SLM intelligent optical application software
  • Instantly detects traffic when connected to live fiber

Specifications:
General (typical at 25°C)
Weight 0.35 kg (0.77 lb)
Dimensions (w × h × d) 128 x 134 x 40 mm (5 x 5.28 x 1.58 in)
Optical Interfaces
Interchangeable optical connectors FC, SC, DIN, LC and ST
Technical Characteristics
Laser safety class (21 CFR) Class 1
Distance units Kilometers, feet, and miles
Group index range 1.30000 to 1.70000 in 0.00001 steps
Number of data points Up to 256,000 data points
Distance measurement Automatic or dual cursor
Display range 0.5 to 260 km
Cursor resolution 1 cm
Sampling resolution 4 cm
Accuracy ±1 m ±sampling resolution ±1.10−5 x distance (excluding group index uncertainties)
Attenuation Measurement
Automatic, manual, 2-point, 5-point, and LSA
Display range 1.25 dB to 55 dB
Display resolution 0.001 dB
Cursor resolution 0.001 dB
Linearity ±0.03 dB/dB
Threshold 0.01 to 5.99 dB in 0.01 dB steps
Reflectance/ORL Measurements
Reflectance accuracy ±2 dB
Display resolution 0.01 dB
Threshold −11 to −99 dB in 1 dB steps
CW Source
CW Source output power leve −3.5 dBm
MP OTDR (typical at 25°C)
Central wavelength 1310 ±20 nm
1550 ±20 nm
1650 ±20nm
Pulse width 3 ns to 20 µs
RMS dynamic range 43 dB
41 dB
40 dB
Event dead zone 80 cm
Attenuation dead zone 4 m
   



For full JDSU 4138 RMP65 product specifications, please click here: JDSU 4138 RMP65

JDSU 4138 RMP695 SM 1310 / 1550 / 1650nm Long Haul Fiber OTDR Module

For Use With JDSU T-BERD 2000 & 4000 OTDR Mainframes
(OTDR Mainframe Not Included In Sale!)

Dynamic Range:
1310 / 1550 / 1650 nm : 43 / 41 / 40 dB

4138RMP65 4138-RMP65

JDSU 4138 RMP65 4138RMP65 OTDR Module Models On Sale Warranty Calibration Backed by The Best Service and Lowest Prices in the Industry.

 

BC# 41635-L/T*

  • JDSU 4138 RMP65 SM Long Haul Fiber OTDR Module (BC# 41635-L/T*)
    • SM OTDR Source:
      • 1310nm
      • 1550nm
      • 1650nm
Request a Quote for

Have Questions or doubts? Submit the following request and expect our detailed quote within 24 hours!

we are commited to win your business!