Ideal Lantek II kit with accessories

IDEAL LANTEK 2 1000 Cat6 Cat6a LAN Cable Certifier (Lantek II-1000)

EXFO LFD-100 kit with accessories

EXFO LFD-100 Live Fiber Detector LFD 100

WWG Acterna OLP-18C SM MM Fiber Power Meter

$125.00
Availability: In stock
SKU
4P65

Condition: Refurbished / Calibrated

Warranty: 90 Day Exchange

The OLP-18C is a compact, high performance optical power meter for installation, maintenance and repair in fiber optic networks. They can be used on their own for simple system power measurements, or with a light source for insertion lossmeasurements.

The full functionality of the high performance OLP range is realized when used with an Acterna Optical Light Source (OLS).

Together with a variable optical attenuator the OLPs are the right instruments for the commissioning of optical transmission systems, for example: DWDM systems.

Highlights

  • Easy report generation with FiberASSISTANT software
  • Data storage and RS-232 interface
  • Rugged, impact resistant, splash-proof
  • Three year recalibration period
  • High precision, easily exchangeable adapter including UPP

High performance measurement
High performance OLPs feature a wide dynamic range making them suitable for use in many different applications. The OLP-18C is designed for those with high power levels such as CATV systems, optical amplifiers and DWDM systems.

Precision calibration to traceable national standards ensures high accuracymeasurement in user selectable units. Two unique Universal Push Pull (UPP) adapters provide reliable, reproducible connection to all common 1.25 and 2.5 mm connectors, ensuring the user always has the correct connection in the field.

Absolute power level can be stored with a single keystroke, making it easy to take relative loss test measurements.

AutoWavelength Detection and TwinTest
Used with an Acterna Optical Light Source (OLS), high performance OLPs feature two powerful functions, designed to avoid the possibility of measurement errors.

The AutoWavelength Detection function detects the actualwavelength being used and switches automatically to the appropriate wavelength range. TwinTest performs two wavelength loss measurements automatically.

Automatic identification of individual fibers
High performance OLPs can be used to detect the modulation frequency of the fiber to be measured, for identification purposes. To speed this process, an audible signal identifying the fiber as one of four standard frequencies sounds as soon as the fiber is brought near the input.

Data storage
High performance OLPs can store up to 1000 sets of testmeasurements. Data can be downloaded to a printer for hard copy records, or to a PC for long-term storage and further analysis using Acternaメs FiberASSISTANT PC software.

Rugged field instrumentation
OLP-18C features low power consumption for long battery life. It can be operated with AC, dry or rechargeable AA batteries which can be changed in the field very easily. The unit is supplied in a robust housing, with splashproof foil keypad and protectors for the optical connectors, to ensure reliable operation even in harsh field conditions.

Specifications

Wavelength range 800 to 1700 nm
Photodiode filtered InGaAs
Fiber type 9/125 to 50/125 µm
Standard wavelengths, switchable
850, 980, 1310, 1480, 1510, 1550, 1625 nm
Display range -60 to +26 dBm
Max. permitted level + 26 dBm
Intrinsic uncertainty ±0.13 dB (±3%)
Overall measurement uncertainty
For the level range -50 to +23 dBm
850nm ±0.33 dB ±10 nW
1300, 1310 nm ±0.25 dB ±2 nW
1550 nm ±0.25 dB ±2 nW
1625 nm ±0.5 dB ±2 nW
Wavelength detection
automatic switching and display of nominal wavelength
Fiber detection automatic display of line ID
Data memory 1000 measurement results
Data readout/remote control RS-232 interface

Display
Modulation detection
270Hz, 330 Hz, 1 kHz, 2k Hz
Result display LCD, 4 digit
Results displayed in dBm, dB, mW, µW
Resolution 0.01 dB/0.001 µW
Backlight function switchable via separate key
Reference level
transfer of measured value or entry of any reference level in the range ヨ80 to +30 dBm, storage of one reference value per wavelength
Optical connector interchangeable adapter interchangeable adapter from the BN 2014/00.X range suitable for measurements on flat or angled physical contact systems
e.g. 2.5 mm plugs: FC, ST, SC, DIN, E2000, SMA,ナ
e.g. 1.25 mm plugs: LC,MU-Adapter
BN 2014/00.28 and many more
Power supply
Dry batteries x Mignon (AA) 1.5 V
Or NiCd rechargeable cells 2 x Mignon (AA) 1.2 V
Operating time
from batteries typically 36 h
NiCd cells typically 12 h
Batteries/NiCd power saving
the instrument switches off automatically after approx. 20 min (function can be disabled)
AC line operation (OLP-1xC) separate AC adapter
Electromagnetic compatibility
corresponds to EN 50081-1 and EN 50082-1
(CE conformance)
Recommended calibration interval 3 years
Ambient temperature
Nominal range of use -10°C to +55°C
Storage and transport -40°C to +70°C
Dimensions (w x h x d) Approx. 95 x 49 x 185 mm
Weight Approx. 500 g



For full JDSU OLP-18C product specifications, please click here: JDSU OLP-18C

WWG Acterna JDSU OLP-18C High Performance Optical Power Meter

Power Meter Test Capabilities
850nm
980nm
1310nm
1480nm
1510nm
1550nm
1625nm

OLP 18C OLP18C

JDSU OLP-18C OLP18C SM MM Fiber Power Meter Models On Sale Warranty Calibration Backed by The Best Service and Lowest Prices in the Industry.

 

BC#: 07385 07386

  • WWG OLP-18C High Performance Optical Power Meter (BC#: 07385 07386)
    • 850nm
    • 980nm
    • 1310nm
    • 1480nm
    • 1510nm
    • 1550nm
    • 1625nm
  • Interchangeable SC Connector
  • Fiber Cables:
    • SM SC-SC
    • MM SC-SC
  • User Manual
Request a Quote for

Have Questions or doubts? Submit the following request and expect our detailed quote within 24 hours!

we are commited to win your business!