KL-300T
The KL-300T Core Alignment fiber optic fusion splicer made by Jilong
Communication is a solid reliable addition to any Technician’s tooling. In side
by side specification comparisons the KL comes up first in more categories than
the big three, Fujikura, Sumitomo or Fitel. The 300 triumphs in attributes like
a 39 second splice/shrink cycle time, the second highest magnification on the
market and lighter weight than all other standard fusion splicers.
But
the KL-300T stands out even more with features that can’t be weighed &
measured and put into a chart. Each and every time you interact with this
machine you will appreciate features like a lighted fusion area, the largest
screen on the market, a high resolution graphical user interface, easy to
interpret universal buttons and frustration free menu navigation. Additionally
when you see the video from the high resolution cameras you’ll know you’ve got a
machine that will spoil you.
Features:
- Core to core alignment by PAS technology
- ( PAS:Profile Alignment System)
- Digital fusion splicer with automatic focus function
- Fiber core can be display clearly
- Single X or Y view and X & Y view simultaneously
- Auto detect cleaved endface fault
- Display fiber cleaved and offset angle
- Display core and clad offset
- 5.6 inch TFT color LCD monitor with clear digital image display
- USB & VGA interface
- Software upgrade via USB interface
Specifications:
| Model |
KL-300T |
| Applicable fibers |
SM (ITU-T G.652), MM (ITU-T G.651), DS
(ITU-T G.653), NZDS (ITU-T G.655) |
| Fiber cleaved length |
8~16mm(Coating
diameter:250µm) 16mm(Coating diameter: 250 ~
1000µm) |
| Fiber diameter |
Cladding diameter:80 ~150µm
Coating diameter:100~ 1000µm |
| Fiber Count |
Single |
| Fiber aligning method |
Core or clad aligning |
| Image processing method |
Digital |
| Actual average splice loss |
0.02dB (SM), 0.01dB (MM),
0.04dB (DS), 0.04dB( NZDS) |
| Splicing time |
Typical 9 sec,with standard SM
fiber |
| Splicing mode |
53(templet), 40(user) |
| Splice loss estimate |
More accurate |
| Return loss |
>60dB |
| Storage of splice result |
4000 results,20 parameter per
result |
| Fiber display and magnification |
300X(X or Y view),150X(X and Y
view) |
| Tube heating time |
Typical 30 sec |
| Tube heating mode |
9(templet), 24(user) |
| Tube heating temperature |
Can be adjusted |
| Applicable Protection sleeve length |
60mm, 40mm and a series of micro
sleeves |
| Tension test |
2N |
| Electrode life |
2500 |
| No.of splice/heating with battery |
Typical 150 cycles (splice/tube heat)
with inner Li-battery |
| Display screen |
5.6 TFT inch color LCD monitor |
| Image change over |
The fiber image is turned upside
down |
| Terminals |
USB 1.1 and VGA |
| Operating condition |
0 ~ 5000m above sea level, 0 ~
95%RH and -10~50°C, respectively, Max.
wind velocity of 15m/s |
| Power supply |
AC 100-240V with AC adapter; inner
Li-battery(6600mAH) |
| Dimensions |
150mm(L) x150mm (W) x150mm (H) |
| Weight |
2.7 Kg excluding battery,3.2 Kg
including battery |
| Splicing mode |
Auto \Calibrate
Normal \Special |
| Fiber cleaved angle threshold set |
0.1 - 10.0 °
0.1°step |
| Display fiber cleaved angle |
• |
| Display fiber offset angle |
• |
| Auto aligning |
• |
| Auto detect cleaved endface fault |
• |
| Display core offset |
• |
| Display clad offset |
• |
| Fiber partial core Compensation |
• |
| Arc strength automatic adjustment |
• |
| Display inside temperature |
• |
| Display ambient temperature |
• |
| Display heater temperature |
• |
| Display air pressure |
• |
| Display battery voltage |
• |
| Taper Splice |
• |
| Sleep |
• |
| Auto Shut down |
• |
| Software upgrade |
• |
The CMA5000 is one of the most modular and flexible field service
offerings from Anritsu. Test Gigabit Ethernet, DWDM, SONET, OTDR, ORL, PMD
and CD all with the same easy-to-use instrument
The CMA5000 is a field portable, network testing platform designed for
installation, maintenance and troubleshooting of next generation, convergence
networks. It features a common user interface, open architecture design and
numerous test technologies that allow the platform to evolve with user testing
needs and address ever-changing telecommunication
infrastructures.
Comprehensive physical layer characterization is
simplified with all required testing applications including OTDR, Optical
Spectrum Analysis, Loss Test Set and Optical Return Loss. Supplemental
tools such as a Visual Fault Locator and Video Inspection Probe are also
available providing a complete testing solution. As services are deployed, the
CMA5000 expands to certify performance of Gigabit Ethernet and SONET/SDH
networks up to 10Gb/s.
Why choose the CMA5000?
Common platform supports all the tools needed for:
- Fiber installation and maintenance
- Rapid isolation of network problems
- In-depth analysis and monitoring of network performance
It combines Best-in-Class performance with:
- Exceptional ease-of-use
-Accurate results with little or no
training
- Common feature set across different test applications
- Leads to
greater productivity
- One button tests that speed troubleshooting
- Faster time to restore
service
- Multi-layer test capability
- Quickly isolate and resolve complex
network problems
CMA5000 provides significant advantages:
- The CMA5000 reduces the total cost of measurement
- Common platform
reduces the number of “boxes” needed to perform routine and emergency
testing - Common user interfaces reduces training required for effective
use of different applications
- The CMA5000 provides increased customer revenue
- Simple bandwidth
utilization monitoring leads to network optimization - Fast, efficient
testing enables rapid restoration of existing services and quicker deployment
of new ones
- Simple Go/NoGo tests are always backed up with detailed data for manual
analysis
Even though the unit is simple for the novice, the experienced users can
drill down to get more in-depth results
Today’s telecommunication professionals are faced with unprecedented
challenges ranging from accelerating the deployment of highspeed communications
services to reducing costs, including capital expenditures. NetTest answers
these challenges with the CMA 5000 Multi-Layer Network Test Platform.
The CMA 5000 is the industry’s premier test and measurement solution designed
with the high performance and scalability necessary to meet the stringent
demands of telecommunication professionals while simultaneously accelerating the
deployment of new services and reducing the total cost of measurement.
Reduce the Total Cost of Measurement One platform
providing complete testing solutions for multiple network layers saves time by
minimizing training, increasing user efficiency, reducing equipment inventory,
and decreasing test time via best-in-breed specifications - reducing the total
cost of measurement.
Accelerate the Deployment of Services Unparalleled
performance for all applications allows networks to be characterized and
commissioned faster than the competition, thereby providing accelerated time to
revenue.
Optimize Performance and Bandwidth The CMA 5000 fully
characterizes each fiber and network for maximum performance and revenue
generation.
Specifications:
| Wavelength |
Optical fiber type |
Pulse width |
Dynamic Range (SNR=1) |
Deadzone (back-scattered) |
Deadzone (Fresnel) |
| 850±30 nm 1300±30 nm 1310±20 nm 1550±20 nm |
Multimode(62.5 um), SingleMode(8-10 um) |
Singlemode: 5, 10, 20, 50, 100, 200, 500, 1000,
2000, 5000, 10000, 20000 ns Multimode: 5, 20, 50, 100, 200, 500, 1000
ns |
24/26/35/35 dB |
7/8/10/10m |
5/5/5/5m |
| Distance Range |
Single mode: 5, 20, 50, 75, 125, 250, 300 km
Multimode: 5, 15, 20, 40, 64 km |
| Sampling resolution |
Single mode: 0.125, 0.5, 1, 2, 4, 8, 16 m
Multimode: 0.125, 0.5, 1, 2, 4 m |
| Sampling Points |
Up to 256,000 |
| IOR settings |
1.300000-1.700000 |
| Distance Measurement Accuracy |
0.0025% of distance measurement± distance
resolution ± index uncertainty |
| Loss Measurement accuracy (linearity) |
±0.04 dB/dB |
| Loss Resolution |
0.001 dB |
| Laser Safety |
Meets IEC60825-1 Class I and CDRH Class 1
Requirements (Eye Safe) 21 CFR 1040 |
| Optical Connector |
Single mode: Universal with UFC, USC, UST, AFC,
ASC Multimode: Universal with FC, SC, ST |
| Operating Modes |
Fault Locate, Standard OTDR, Construction
(Automated Multi-wavelength, Multi-fiber testing), NetWorks (data
processing and report generation) |
JDSU OLS-6 Pocket-sized dual wavelength light sources,
1310 and 1550 nm
- Pocket class: Rugged, compact and lightweight
- Easy-to-use, straight forward operation
- Reliable basic functionality for most economical testing
- Three year calibration period
- OLS-6: dedicated for single mode at 1310 and 1550 nm
- Standard AA batteries or NiMH/NiCd cells
- FTTx ready
The JDSU OLS-6 pocket-sized light sources are the result of JDSU's many years
of experience in optical measurement technology. They are designed for dual
wavelength measurement alongside JDSU's pocket-sized or Smart optical power
meters.
The rugged OLS-6 is really pocket-sized and fit into a handy belt
bag so they are always ready to use. The simple three-button operation together
with an easy-to-read display makes them extremely easy-to-use.
The OLS-6
is designed for dual wavelength measurement in various single mode applications.
It has separate optical laser ports for each wavelength (1310 nm and 1550 nm,
1490 nm and 1550 nm, or 1550 nm and 1625 nm). Together with an JDSU optical
power meter (OLP) the automatic wave-length detection guarantees fast and
error-free results.
The 1625 nm wavelength of the OLS-6 allows additional
tests for detection of micro/macro-bending effects at optical fibers. This makes
it ideal for dense wavelength division multiplexing (DWDM) applications.
The OLS-6 with 1490/1550 nm is specially designed for tests in FTTx
applications.
|
Specifications |
|
Functions |
Details for 1310 and
1550 nm |
|
Emitter Type |
Dual FP Laser (laser class 1) |
| Wavelength Range |
1310 nm ± 20 nm |
| 1550 nm ± 20 nm |
| Spectral width (RMS) |
typically <5 nm |
| Output level (CW) |
| 9/125 µm fiber -7 dBm |
typically ± 1 dB |
| Modulated output level |
typically -10 dBm |
| Level stability (Short-term) |
| 1 h, -10 to +55°C |
typically ± 0.03 dB |
| Level stability (Long-term) |
| 8 h, -10 to +55°C |
maximum ± 0.25 dB |
| Modulated output signal (Rectangular, modulation
ratio 1:1); |
| Selectable |
270 Hz, 1 kHz, 2 kHz |
| Modes |
| CW |
continuous wave signal |
| Auto-? |
output signal includes ?
information (detectable by all JDSU power meters) |
| FMOD |
modulation for fiber
identification 270 Hz, 1 kHz, 2 kHz |
| Dual |
Both wavelengths
activated |
| Optical connector |
Two outputs (one for each
wavelength) each with the same connector (to be selected when ordering)
FC/PC, SC/PC |
JDSU OLS-5 Pocket-sized dual wavelength light sources,
850 - 1300 nm
- Pocket class: Rugged, compact and lightweight
- Easy-to-use, straight forward operation
- Reliable basic functionality for most economical testing
- Three year calibration period
- Dedicated for multimode at 850 and 1300 nm
- Standard AA batteries or NiMH/NiCd cells
- FTTx ready
The JDSU OLS-5 pocket-sized light sources are the result of JDSU’s many years
of experience in optical measurement technology. They are designed for dual
wavelength measurement alongside JDSU’s pocket-sized or Smart optical power
meters.
The rugged OLS-5 is really pocket-sized and fit into a handy belt
bag so they are always ready to use. The simple three-button operation together
with an easy-to-read display makes them extremely easy-to-use.
For
multimode applications the OLS-5 is the ideal choice. Via one single port 850
and 1300 nm LEDs are connected to the test cable. Together with an JDSU optical
power meter (OLP) automatic wavelength detection and TwinTest guarantee fast and
error-free results at a high test speed.
|
Specifications |
|
Emitter Type |
LED
(laser class 1) |
| Wavelength
Range |
850 nm ± 20 nm
1300 nm ± 50 nm |
| Spectral width (FWHM) |
850nm |
| 1300
nm |
| Output level
(CW) |
50/125 µm fiber
|
-20 dBm
± 1.7 dB |
| 62.5/125 µm fiber
|
-17 dBm
± 3 dB |
| 100/140 µm fiber
|
-13 dBm
± 3 dB |
| 9/125 µm fiber
|
-40 dBm
± 3 dB |
| Modulated output
level |
3 dB
less than in CW mode |
Level stability
(short-term) |
15 min, +23°C ±3 K,
?T = ± 0.5 K |
± 0.25
dB |
15 min, -10 to
+55°C, ?T = ± 0.5 K |
± 0.08
dB |
Level stability
(Long-term) |
15 min, +23°C ±3 K,
?T = ± 0.5 K |
± 0.25
dB |
15 min, -10 to
+55°C, ?T = ± 0.5 K |
± 0.08
dB |
Modulated output
signal (Rectangular, modulation ratio 1:1);
Selectable |
1 kHz, 2
kHz |
| Modes |
CW |
continuous wave signal |
| Auto-? |
output
signal includes ? information (detectable by all JDSU power
meters) |
| FMOD
|
modulation for fiber identification 270 Hz, 1 kHz, 2
kHz |
| TWINTest
|
Automatic toggling between 850 nm and 1300 nm |
| Fixed optical
connector |
ST |
JDSU OLP8 The JDSU OLP8 was designed for the installation and maintenance
of singlemode and multimode cables, systems, and networks
The JDSU OLP product line of pocket-sized optical power meters provides an
excellent price/performance ratio for universal, singlemode loss test and
systems power measurements.
Highlights
- TWINtest cuts test time in half and simplifies handling due to automatic
attenuation measurements at 850/1300 nm or 1310/1550 nm.
- Auto-lambda automatic wavelength detection and simple fiber identification
together with an JDSU OLS light source.
- Easy three-button operation lets you concentrate on your work at hand.
- Lightweight, portable, rugged, and shock-proof design guarantees long
life.
- Includes a handy nylon belt pouch.
Applications
- The OLP-6 is the universal solution for telecommunications applications
with a dynamic range of -65 to +10 dBm.
- The OLP-8 is the solution for the measurement of high optical power values
in the range of -50 to +23 dBm.
Key Features
- Extra long battery lifetime (>130 hours).
- Battery replacement indicator.
- Powered from standard dry batteries or rechargeable cells.
|
Specifications |
|
Display range |
-50 to +23 dBm |
| Max. permitted input
level |
+23 dBm |
| Accuracy |
| Intrinsic
uncertainty |
± 0.20 dB (± 5%) |
| Linearity |
± 0.06 dB (-35 to +20
dBm) |
| Wavelength
range |
780 to 1650 nm |
| Standard wavelength
settings |
980, 1310, 1480, 1550
nm |
Wavelength and modulation detection together with
OLS-5, OLS-6, OLS-55/56, OLT-55 |
270 Hz, 330 Hz, 1 kHz, 2
kHz |
| 1310, 1550
nm |
-35 to +23 dBm |
| 980
nm |
-30 to +23 dBm |
Connectable fiber types |
9/125 µm to 10/125
µm |
|