New instruments with state-of-the-art displays based on the popular, field proven USN Series!

Now, there are ultrasonic flaw detectors with all the features you need for inspection in bright sunlight as well as in dark or poorly lighted conditions.

Krautkramerメs USN-L Series portable ultrasonic flaw detectors can be read easily in bright, direct sunlight. New モtransreflectiveヤ technology actually uses sunlight to make the display more visible outdoors.

The new USN-L instruments have a fast 60 Hz update rate,LCD display and a fine screen resolution of 480 x 320 pixels . Backlighting is used for excellent visibility indoors or in dark conditions. The L Series instruments include the USN 50L and the USN 52L providing a choice of ultrasonic features to address individual applications.

Trigonometric Flaw Location Function provides measurement information concerning the location of a discontinuity detected during an angle beam test. The function automatically calculates and displays the sound path, projected distance and depth when the instrument is properly calibrated.

Thickness Measurement and Data Recording are provided. Selectable thickness modes enable you to choose the best method for your job. The sequential datalogger provides thickness recording of up to 2500 readings in up to 99 configurable files. Evaluate the first echo in the gate or measure between two echoes - it doesnメt matter if the material is painted: you only measure thickness of the metal through paint.

Features:
  • 6 pounds (2.7 kg) total weight with batteries
  • Powered by standard NiCad or alkaline D-Cell batteries
  • Dataset memory with memory flag
  • Trigonometric flaw location
  • Digital measurement resolution: .001ヤ (.1 mm)
  • Thickness datalogger with 2500 readings
  • Two measurement gates
  • Display zoom feature
  • Gate magnify feature
  • RS-232 biderectional port
  • A-Scan store, freeze and print
  • Multiple language selections
  • High and low rep rate control
  • High and low damping control
  • Broadband amplifier
  • Dataset memory for 30 datasets

Specifications:
Range 0.2" to 200" at steel velocity (5mm to 5000mm), range selectable in fixed steps, or continuously variable
Velocity Continuously adjustable from .0394 to .3936 in/µsec (1000-9999 m/second); 2 programmable fixed velocities
Delay Minus 20 µsec to 999 µsec
Zero Offset 0 to 1600 µsec
Gain 0 to 110 dB controllable in selectable gain steps 0.1, 0.5, 1.0, 2.0, 6.0, and 24.0 (24dB step is programmable to other values)
Test Modes Pulse echo and dual
Pulser Spike/excitation pulse
Pulse Repetition Frequency Selectable, low & high; varies w/range
Rectification Positive halfwave,negative halfwave,fullwave
Reject (suppression) Controllable 0 to 80% absolutely linear
Units Inch or millimeter selectable
Display 4.5" x 3.0" (114mm x 76mm) Transreflective LCD with backlight 60 Hz update rate
Pixel density 480 x 320
Gate Monitor Controllable over entire sweep range in 0.1mm increments. Alarm indication by LED. Threshold controlled 10% to 90% screen height. Separate second threshold and start control in multi-echo measurement mode.
Measurement Modes Zero to first echo, 0.001" (0.1mm) resolution up to 10" (245mm) ; multi-echo in gate with controllable second threshold; time-of-flight to peak or flank in gate; amplitude evaluation as % FSH or above threshold to 127%; dB reference indicates REF gain and addition or subtraction; trigonometric flaw location
Memory Dataset memory locations store all instrument parameters plus A-Scan. Recall function displays stored dataset.
Data Logger 2,500 reading sequential thickness measurement storage with clear, review and direct report feature; configurable up to 99 files.
Operating Temperature 0°C to 55°C (ヨ20°C to +70°C survivable)
Outputs Gate violation output on open collector, digital thickness value output on serial interface
Language Selectable English, French, Spanish, Italian, Portuguese, German, Dutch, Danish, Finnish, Norwegian, Swedish, Russian
Connectors BNC or Lemo selectable at order
Keypad International symbols
Battery Power 6 D-size alkaline or NiCad cell up to 12 hrs operation
Size 9.8"Wx5.25"Dx5.75"H(249mmx133mmx146mm)
Weight 6lbs (2.7kg) with NiCad batteries 3.10lbs (1.4kg) without batteries
Damping Selectable: High and Low
Amplifier Bandpass Broadband: 0.4 MHz to 10.2 MHz
Memory 30 dataset memory locations with rapid clear functions, memory flag and A-Scan preview

 

KrautKramer USN 50L Ultrasonic Flaw Detector Thickness Gauge

Krautkramer’s USN-L Series portable ultrasonic flaw detectors can be read easily in bright, direct sunlight, new “transreflective” technology actually uses sunlight to make the display more visible outdoors

Includes Carrying Case & Accessories As Listed

USN50L USN-50L

KrautKramer USN 50L USN50L Ultrasonic Flaw Detector Models On Sale Warranty Calibration Backed by The Best Service and Lowest Prices in the Industry.

BC# 20009-L/T*

  • KrautKramer USN 50L Ultrasonic Flaw Detector Thickness Gauge (BC# 20009-L/T*)
  • (2) BNC Cables
  • Runs Off (6) "D" Batteries
  • Carrying Case (G)