AFL NOYES M100-K-SM Singlemode Fiber OTDR
Condition: Refurbished / Calibrated
Warranty: 90 Day Exchange
The Noyes M100 OTDR is the world'''s first handheld, singlemode and multimode, four-wavelength Optical Time Domain Reflectometer with integrated VFL (visual fault locator).
M100 is ideal for premises network Tier 2 fiber link certification and fault-location measurements including: connection loss and reflectance, splice loss, and fiber loss slope (attenuation rate).
The M100 is also suited for broadband service providers looking for a highly portable OTDR to document and trouble-shoot fiber links in their access and FTTx (fiber to the home/curb/office) networks.
Features:
- Hand-held size and < 2.7 lb (1.2 kg)
- 850/1300/1310/1550 nm
- Integrated Visual Fault Locator (650 nm)
- OTDR port adapters (ST/SC/FC)
- Bellcore (GR-196) file format
- Compact Flash memory card
- PC software for trace analysis and printing
- Active-matrix colour display
Applications:
- Premises network "Tier 2" certification
- Broadband/access network testing
- Baseline tracing
- Fault-location
- Connection loss and reflectance
- Splice verification CATV and DWDM networks
SINGLEMODE SPECIFICATIONS:
- Emitter type: Laser
- Safety class: Class I FDA 21 CFR 1040.10 & 1040.11
- Center wavelengths: 1310/1550 nm
- Wavelength tolerance: ± 30 / ± 30 nm
- Dynamic range: 26/ 26 dB @ 10 ?s, 3 min. test
- Event dead zone: 6 m
- Attenuation dead zone: 20 m
- Pulse width: 30 ns, 100 ns, 300 ns, 1, 3, 10
- Distance ranges: 300 m to 160 km
Miscelaneous:
- Group Index of Refraction adjustment range: 1.4000 to 1.6000
- Trace file format: Bellcore GR-196, Version 1.1
- Trace file storage medium: CompactFlashル Type 1 memory card
- Trace file storage capacity: > 200 per 16 MB CF memory card
Visual Fault Locator:
- Emitter type: Laser
- Safety class: Class II FDA 21 CFR 1040.10 & 1040.11; IEC 825-1: 1993, EN60825-1: 1994
- Wavelength: 650 nm
- Output power (nominal): 0.8 mW into 9/125 Single-mode or multimode optical fiber
General:
- Size: (H x W x D): 190 x 100 x 70 mm (7.5 x 4 x 2.75 inches)
- Weight: 1.2 kg (2.7 lb)
- Operating temperature: 0 oC to + 40 oC
- Storage temperature: -10 oC to + 60 oC
- Relative humidity: 0 to 95% RH (non-condensing)
- Power: Rechargeable NiMH or 110/220 VAC adapter
- Battery life: > 2 hours
For full Noyes M100-K-SM product specifications, please click here: Noyes M100-K-SM
NOYES M100-K-SM Singlemode 1310nm/1550 Fiber OTDR With VFL
Dynamic Range
1310/1550 nm : 26/ 26 dB
Includes Carrying Case And Accessories As Listed!
M100 M 100 M100-K
Noyes M100-K-SM M100KSM OTDR Module Models On Sale Warranty Calibration Backed by The Best Service and Lowest Prices in the Industry.
- Noyes M100-K-SM Singlemode OTDR
- Source:
- 1310nm
- 1550nm
- Interchangeable FC Connector
- VFL
- Interchangeable 2.5mm Universal Connector
- Source:
- (2) SM FC-FC Fiber Cables
- (6) Fiber Optic Cleaning Pads
- AC Adapter/Charger
- Power Cord
- OTDR Emulation Software
- User Manual On CD-ROM
- Carrying Case