 Olympus 38DL Plus
The 38DL PLUS is an innovative instrument that signals a new era in ultrasonic thickness gaging. Ideally suited for almost every ultrasonic thickness application, this handheld thickness gage is fully compatible with a full line of dual and single element transducers. The versatile 38DL PLUS can be used in applications ranging from wall thinning measurements of internally corroded pipes with dual element probes to very precise thickness measurements of thin or multilayer materials with single element transducers.

The 38DL PLUS comes standard with many powerful but easy-to-use measurement features and a host of application-specific software options. Its sealed case is designed to meet IP67 requirements to withstand the rigors of very wet or dusty environments. The color transflective VGA display provides superior readability from bright sunlight to complete darkness. It features a simple, ergonomic keypad that can be operated with the left or right hand for easy access to all functions.

The 38DL PLUS is designed to meet the challenges of demanding applications and built to withstand tough conditions in the field and on the production floor. Whether you work in very wet or dusty conditions, cold or hot climates, or bright or dark areas, the 38DL PLUS can handle any inspection job. Need an instrument tough enough to tolerate shocks, drops, and rough handling? The 38DL PLUS with its protective rubber boot and designed for IP67 rating is your answer.

Built for Tough Environments:
  • Compact, weighs only 0.814 kg (1.80 lb)
  • Rugged, designed for IP67
  • Explosive Atmosphere: Safe operation as defined by Class I, Division 2, Group D, as found in the National Fire Protection Association Code (NFPA 70), Article 500, and tested using MIL-STD-810F, Method 511.4, Procedure I.
  • Shock tested using MIL-STD-810F, Method 516.5, Procedure I, 6 cycles each axis, 15 g, 11 msec Half sine
  • Vibration tested using MIL-STD-810F, Method 514.5, Procedure I, Annex C, Figure 6, general exposure: 1 hour each axis.
  • Wide operating temperature range
  • Color transflective VGA display with indoor and outdoor color set ings for superior clarity
Designed for Easy Operation:
  • Simple keypad for right hand/left hand operation
  • Easy operator interface with direct access to all functions
  • Internal and External MicroSD memory card storage
  • USB and RS-232 communication ports
  • Alphanumeric data logger with 475,000 thickness readings or 20,000 waveforms
  • VGA output to connect to computer or monitor
  • Default/Custom dual element transducer setups
  • Default/Custom single element transducer setups
  • Password protected function allows locking of instrument features
Thickness Measurements on Internally Corroded Metals
One of the major applications of the 38DL PLUS is measuring the remaining thickness of pipes, tubes, tanks, pressure vessels, hulls, and other structures affected by corrosion or erosion. Dual element transducers are most commonly used for these applications:
  • Automatic Probe Recognition for standard D79X series dual element transducers
  • Ten custom dual element transducer setups
  • Optimized default gain during calibration for dual element transducer
  • V-Path Builder for custom V-path compensation
  • Calibration Doubling warning when echo doubling may occur during calibration
  • THRU-COAT® and Echo-to-Echo measurements on painted and coated surfaces
  • High temperature measurements; up to 500 °C (932 °F)
  • Boiler tube and Internal Oxide measurements (optional) with M2017 or M2091 single element transducers
  • EMAT transducer (E110-SB) for no-couplant measurements of boiler tubes with external oxide/scale buildup

Data Logger and PC Interface
The 38DL PLUS has a full-featured internal bidirectional alphanumeric data logger that is designed to easily collect and transfer thickness readings and waveform data:
  • Internal memory of 475,000 thickness readings or 20,000 waveforms with thickness readings
  • 32 Character File name
  • 20 Character ID# (TML#)
  • 9 file formats: Incremental, Sequential, Sequential with custom point, 2-D Grid, 2-D Grid with custom point, 3-D Grid, 3-D custom, Boiler, and Manual 
  • The ability to store up to 4 comments (notes) per ID# (TML)
  • Stores comments (notes) at an ID# or to a Range of ID#â??s
  • Internal and External MicroSD memory cards
  • File copy with the ability to copy files between Internal/External MicroSD memory cards
  • Standard USB and RS-232 communication
  • Two-way transfer of both single and dual element transducer setups
  • Onboard statistical report
  • Onboard DB Grid View with three programmable colors
  • GageViewâ?¢ interface program can communicate with the 38DL PLUS using the USB, RS-232 ports, and can read and write to a MicroSD memory card.
  • Direct export of internal files to MicroSD memory card in Excel compatible CSV (comma-separated values) format

Features:
  • Dual and single element transducer compatibility
  • Wide thickness range: 0.08 mm (0.003 in.) to 635 mm (25 in.) depending on material and transducer selection
  • Corrosion thickness gaging with dual element transducers
  • THRU-COAT® and Echo-to-Echo measurements on painted and coated surfaces
  • Standard resolution of 0.01 mm or 0.001 in. for all transducers
  • High Resolution software option of 0.001 mm or 0.0001 in. with single element transducers 2.25 MHz to 30 MHz
  • Thickness, Velocity, and time-of-flight measurements
  • Differential mode and Reduction Rate mode
  • Time-based B-scan mode; 10,000 reviewable readings per scan
  • Olympus High Dynamic Gain technology with digital filters
  • V-Path Builder for custom V-path compensation
  • Designed for EN15317
     
Specifications:
Dual element transducer measurement mode Time interval from a precision delay after the excitation pulse to the first echo
THRU-COAT® measurement Measurement of true metal and coating thicknesses with a single back-wall
echo (with D7906-SM and D7908 transducers)
Thru-Paint Echo-to-Echo Time interval between two successive back-wall echoes to eliminate paint or coating thickness
Single element transducer measurement modes Mode 1: Time interval between the excitation pulse and the first back-wall echo
Mode 2: Time interval between the delay line echo and the first back-wall echo (with delay or immersion transducers)
Mode 3: Time interval between successive back-wall echoes following the first interface echo after the excitation pulse (with delay line or immersion transducers)
Thickness range  0.080 mm to 635.00 mm (0.003 in. to 25.000 in.) depending on material, transducer surface conditions, temperature, and selected configuration
Material velocity range 0.508 mm/µs to 13.998 mm/µs (0.020 in./µs to 0.551 in./µs)
Resolution (selectable) Low: 0.1 mm (0.01 in.)
Standard: 0.01 mm (0.001 in.)
Transducer frequency range Standard: 2.0 MHz to 30 MHz (â??3 dB)
General
Operating temperature range â??10 °C to 50 °C (14 °F to 122 °F)
Keypad Sealed, color-coded keypad with tactile and audible feedback
Case Impact-resistant and water-resistant, gasketed case with sealed connectors. Designed for IP67.
Dimensions (W x H x D) Overall: 125 mm x 211 mm x 46 mm (4.92 in. x 8.31 in. x 1.82 in.)
Weight 0.814 kg (1.80 lb)
Power supply AC/DC adaptor, 24 V; lithium-ion battery 23.760 Wh; or 4 AA auxiliary batteries
Battery life, lithium-ion Operating time: minimum 12.6 h, 14 h typical, 14.7 h maximum Fast charge: 2 h to 3 h
Standards Designed for EN15317
Display
Color transflective VGA display Liquid crystal display, display area 56.16 mm x 74.88 mm (2.2 in. x 2.95 in.)
Rectification Full wave, RF, half-wave positive, or half-wave negative
INPUTS/OUTPUTS
USB 1.0 client
RS-232 Yes
Memory card Maximum capacity: 2 GB External MicroSD memory card
Video output VGA output standard
Internal Data Logger
Data logger The 38DL PLUS identifies, stores, recalls, clears, and transmits thickness readings, waveform images, and gage configuration information through the standard RS-232 serial port or USB port.
Capacity 475,000 thickness measurements or 20,000 waveforms with thickness measurements
File names, IDs, and comments 32-character file names and 20-character alphanumeric location codes with four comments per location
File structures Nine standard or custom application-specific file structures
Reports On-gage reporting of summary with statistics, Min./Max. with locations, Min. review, file comparison, and alarm report



For full Olympus 38DL product specifications, please click here: Olympus 38DL

Olympus 38DL Thickness Gauge 

Measurement Modes:
- Thickness
- Velocimeter
- Time Of Flight

Thickness Range: 0.080 mm to 635.00 mm (0.003 in. to 25.000 in.) (Depending on material, transducer surface conditions, temperature, and selected configuration)

Ideally suited for almost every ultrasonic thickness application, this handheld thickness gage is fully compatible with a full line of dual and single element transducers

Includes Hard Carrying Case & Accessories As Listed 

Gauge

Olympus 38DL Plus 38-DL Plus Ultrasonic Thickness Gage Models On Sale Warranty Calibration Backed by The Best Service and Lowest Prices in the Industry.

 

BC# 42135-L/T*

  • Olympus 38DL Plus Ultrasonic Thickness Gage w/ Options: (BC# 42135-L/T*)
    • Measurements Modes:
      • Thickness
      • Velocimeter
      • Time Of Flight
  • Olympus Thickness Gauge
  • Olympus 221E Steel Gauge
  • AA Battery Holder
  • Olympus Couplant B Glycerin Bottle
  • AC Adapter/Charger
  • Power Cord
  • USB PC Interface Cable
  • Wrist Strap For Unit
  • User Manual On CD-ROM
  • Hard Carrying Case
Request a Quote for

Have Questions or doubts? Submit the following request and expect our detailed quote within 24 hours!

we are commited to win your business!