Powerful cable certification solution for every budget
The OMNIScanner® LT meets your technology needs and your budget requirements for
testing, certifying and documenting copper and fiber networks. That’s because
the LT version has the same digital technology as the OMNIScanner2, but without
some of the “extras,” making it the most affordable solution you can find.
The OMNIScanner LT provides advanced certification for Cat 5/5e/6 cabling
links to 300 MHz delivering unprecedented Level III accuracy. Its superior
diagnostics precisely pinpoint faults, while identifying specific connection
failures, saving you hours of wasted troubleshooting time. You can test cable
compliance with the current TIA/ISO/IEC cabling standards and add powerful
adapters like the OMNI-LIA101S Permanent Link Adapter or OMNIFiber MM or SM
Adapters for superior test capability.
The OMNIScanner LT features:
- Certification for Cat5/5e/6 cabling links - Support up to 300MHz
bandwidth for testing Category 6/Class E links - S-Bands diagnostics for
precise fault location - Intuitive graphical interface for maximum technician
productivity - Pre-installed manufacturer-specific cable libraries -
Compliance with TIA/ISO/IEC cabling standards - The ability to easily manage
and document copper and fiber links with new LinkWare™ Software
From beginning to end of the network testing process, OMNIScanner LT
accelerates your work, simplifies your tasks and delivers higher productivity to
your bottom line.
Speed your testing cycle From beginning to end of the
network testing process, OMNIScanner LT accelerates your work, simplifies your
tasks and delivers higher productivity to your bottom line.
Easy set-up The vendor-specific cable libraries in
OMNIScanner LT make setting up and executing your test operations easy.
Regardless of the type of cable you are certifying, OMNIScanner LT speeds
through the required test with ease.
Digital test technology Built on a digital platform, the
OMNIScanner LT ensures compliance with new standards as they are approved. So
when you purchase an OMNIScanner LT, you know that your investment is
future-ready. The OMNIScanner LT processes the measurement results with Digital
Signal Processing technology. This measurement method has proven to exceed all
other methods for accuracy and repeatability. What does this mean for you?
You’ll get the same answer every time. The OMNIScanner LT rivals the accuracy of
laboratory test equipment.
Pinpoint accuracy You, your customer and your cable
manufacturer will all be reassured by the laboratory standard accuracy of the
OMNIScanner LT - five times more precise than the Level III standards. Fluke
Networks’ patent pending S-Bands™ diagnostics can save hours of confusion about
network problems by instantly identifying (or eliminating) specific connection
failures.
Fiber is a snap Transforms the OMNIScanner LT into a
powerful fiber optic tool for testing and certifying multimode and singlemode
premise fiber networks. The one-button Autotest and simultaneous dual-wavelength
measurement of two fibers is the most productive and reliable method for testing
fiber links. Choose from two adapters: the LED-based OMNIFiber MM adapter is
perfect for multimode fiber networks, while the laser-based OMNIFiber SM adapter
certifies singlemode fiber.
|
General Specifications |
|
| Temperature range, operating |
0° to +40° C |
| Temperature range, storage |
-10° to +60° C |
| Humidity range, operating |
0 to 75% RH, non-condensing |
| Humidity range, storage |
0 to 95% RH, non-condensing |
| Certifications |
CE, CSA |
| Dimensions |
9.00 x 9.85 x 3.94 cm (3.5 x 3.9 x 1.6 in) |
| Weight |
0.11 kg (0.24 lb) |
| Optical transmitter |
|
| Connector |
ST |
| Emitter type |
OMNIFiber MM: LED; OMNIFiber SM: Fabry-Perot (FP) laser |
| Emitter wavelengths |
OMNIFiber MM: 850 and 1300 nm; OMNIFiber SM: 1310 and 1550
nm |
| Power output (minimum) |
OMNIFiber MM: -19 dBm; OMNIFiber SM: -11 dBm |
| Power output stability (8 hours) |
+/- 0.25 dB at 23 C |
| Optical receiver |
|
| Power measurement accuracy |
+/- 0.25 dB at 23 C, 45% to 75% RH, -20 dBm for 850/1300/1310 nm, -10
dBm for 1550 nm |
| Connector |
Interchangeable Connector Adapters: ST, SC, FC, universal |
| Detector type |
InGaAs |
| Calibrated wavelengths |
850 nm, 1300 nm, 1310 nm, 1550 nm |
| Power measurement range |
+ 3 to –55 dBm |
| Power measurement linearity |
+/- 0.25 dB at 23 C |
| Length measurement |
OMNIFiber MM: 2000 m; OMNIFiber SM: 16000 m |
| Length measurement resolution |
OMNIFiber MM: 1 m (1 ft); OMNIFiber SM: 1 m from 0 – 2000 m OMNIFiber
SM: 2 m from 2001 – 16000 m |
Includes:
- Fluke Networks OMNIScanner LT Main - Fluke Networks OMNIScanner LT
Remote - Fluke Networks OMNIFiber Multimode 850nm/1300nm Module Set -
Microtest OMNIFiber Singlemode 1310nm/1550nm Module Set - (2) Fluke Networks
OMNIScanner Universal Permanent Link Adapters - Fluke P/N: 2950-4015-02 Set
Reference Adapter - Fiber Cables: - - (2) MM ST-ST - - (2) SM
ST-SC - SC-SC Fiber Connector - Fluke Linkware Cable Management Software
- (2) Battery Packs - (2) AC Adapters/Chargers - (2) Power Cords
- Set of PM06s - RS-232 PC Interface Cable - User Manual On CD-ROM
- Soft Carrying Case
|