Hioki 9438 Banana To Alligator Clip Test Leads (1 Grey, 2 Black, 1 Red, 1 Blue, 1 Yellow)
AC Adapter/Charger
Power Cord
RS232 PC Interface Cable
User Manual On CD-ROM
Strap For Unit
Hard Carrying Case
Hioki 3196 Power Quality Analyzer
Measure power factor
Sags
Swells
Flicker
Transients
Harmonics
High Frequency transient
Detection and waveform display
Four current and Four voltage channels
The 3196 POWER QUALITY ANALYZER is a highly
advanced measuring instrument that can monitor and record abnormal phenomena
related to power supply quality and analyze the causes of problems that lead to
incorrect operation of electrical equipment. By simply connecting the 3196 to
the power line to be monitored, you can accurately record the exact timing and
types of power supply abnormalities that has occurred, and display a list of the
events recorded.
An especially noteworthy feature of the 3196 is its
gap-less recording capability (the ability to measure and record events
continuously without loss of measurement data), which is necessary for analyzing
the quality levels of factors such high frequency voltage, RMS voltage, power,
3-phase systems, harmonics as well as the power supply's K factor and flicker.
The ability to instantly display details about items such as monitored waveforms
simply by selecting them from an event list makes analysis easier. Although
other instruments are available in the market for analyzing power supply
quality, none of them have been capable of measuring all types of events
simultaneously on a single instrument; this is what makes the 3196 such a
notable development in supporting analysis of power supply
problems.
Measurements can be taken from single-phase 2-wire,
single-phase 3-wire, 3-phase 3-wire, or 3-phase 4-wire lines. Additional input
channels are provided for voltage and current (one each), and support is
provided for separate system measurement, DC voltage, and neutral wire
measurement.
Up to one month of continuous measurement data can be
recorded in internal memory. Further, data can be saved to a PC card (an ATA
flash card of up to 528 MB) as well as to internal memory. The 3196 also comes
equipped with an HTTP server function, eliminating the need for special-purpose
interface applications and allowing you to use any general web browser (such as
Internet Explorer) for full remote monitoring and control.
The 3196 POWER
QUALITY ANALYZER is a state-of-the-art measuring instrument that serves as a
powerful aid to resolving various kinds of power supply problems. The trend
toward power liberalization has been accompanied by an increase in problems with
power quality, resulting in a steady need for power quality analyzers. Recently,
the rapid growth in use of electronic devices such as computers has been
accompanied by an increase in problems with electronic systems in places such as
factories and businesses, making monitoring of power supply problems a topic of
increasing concern. Also, with the restructuring of the energy business
(deregulation of power, sale of electricity, dispersed power supplies, and
cogeneration), more countries are paying attention to power supply quality, and
the importance of power supply quality analyzers has grown. The 3196 is the
answer to these needs by being able to simply and faithfully capture power
supply abnormalities and analyze various kinds of
problems.
Applications
Power delivery - For businesses that supply and sell electricity (such as
power companies): Maintenance and management of power supply quality, and
cause analysis when power supply problems occur.
Power system facilities - For manufacturers of transformer equipment,
electrical safety organizations, and electrical constructors: Evaluation and
maintenance of power facilities, and periodic maintenance and power quality
problem analysis during system operation.
Large electrical facilities - Evaluation and problem analysis for
semiconductor manufacturing equipment, vending machines, OA equipment, UPS
equipment, air conditioners, and welders.
Maintenance and inspection at factories - All types of power supply
quality maintenance and problem analysis, such as power line maintenance and
management at factories, maintenance and management of production equipment,
energy conservation for ESCO businesses, building maintenance, maintenance and
management of treatment equipment at clinics and hospitals, maintenance and
management of communications equipment, etc.
Frequency, Voltage, Current, Current peak,
Active/Reactive/Apparent power, Power factor (displaced power
factor)
Three phase quality:
Voltage unbalance ratio, Current unbalance
ratio
Harmonic quality (Up to 50th order):
Harmonic voltage, Harmonic current, Harmonic
power, Inter-harmonic voltage, Inter-harmonic current, Harmonic voltage
current phase angle, Total harmonic voltage distortion, Total
inter-harmonic current distortion (THD-F, THD-R), Total inter-harmonic
voltage distortion ratio, Total inter-harmonic current distortion ratio
(THD-F, THD-R), K factor,
Internal memory
13 MB
Interface
PC card slot (9727/ 9728 PC card, 256MB
to 512MB), RS-232C, LAN (10BASE-T)
Power supply
12 V DC output AC ADAPTER 9458
(Universal 100 to 240 V AC, 50/60 Hz), or BATTERY PACK 9459 (7.2 V/2450 m
Ah Ni-MH)