Authorize.Net Secure Checkout   Buy Now Pay Later  
Fusion Splicers Corning Siecor Splicers
 
 
 
 
 
Smart Phone Users
Scan Here To Bookmark This Page
 
 

2D22 - Siecor Corning M90 5000 Series Fusion Splicer

Siecor Corning M90 5000 Series Core Alignment LID-SYSTEM  Fusion Splicer

Includes 6 Month Fusion Splicer Care Kit (FS6MC)
- 4oz Flip Jar Of 99% Alcohol
- (50) Non-Lint Dry Wipes
- (6) Fiber Optic Wipes w/ 99% Alcohol
- 2oz Pump Fast Evaporating Mirror Spray
- (25) Camera Swabs
- (25) V-Groove Swabs

Includes Siecor FBC-005 High Precision Fiber Cutter, Siecor Heat Shrink Oven & Accessories As Listed!

M 90 M-90





Regular Price:$ 4,995.00 / Each
Sale Price:$ 4,495.00 / Each
You Save:$ 500.00 / Each


 
 
 
Condition Refurbished / Calibrated
Warranty 90 Day Exchange
Included
  • Siecor Corning M90 5000 Series Fusion Splicer
  • Siecor FCB-005 High Precision Fiber Cutter
  • Siecor 546999-M7-5385 Heat Shrink Oven
  • Clauss CFS-2 Fiber Optic Stripper
  • Single Fiber Holder Sets:
    • 250
    • 125/900 
  • 6 Month Fusion Splicer Care Kit FS6MC:
    • 4oz Flip Jar Of 99% Alcohol
    • (50) Non-Lint Dry Wipes
    • (6) Fiber Optic Wipes w/ 99% Alcohol
    • 2oz Pump Fast Evaporating Mirror Spray
    • (25) Camera Swabs
    • (25) V-Groove Swabs
  • Overhead Work Lamp
  • Power Cord
  • RS232 PC Interface Cable
  • User Manual On CD-ROM 
  • Integrated Hard Case
 

The microprocessor controlled fusion splicer is used for mechanically durable, low-loss fusing of optical fibers with long-term stability.

Fiber Diameters
Single-mode fibers, dispersion-shifted single-mode fibers and multimode fibers with coating diameters of up to 900 um can be fused. The splicer is designed for use with the standard 125 um outside fiber diameter (without coating). If you need to splice fibers with other diameters, please contact the manufacturer.

Automatic Fiber Positioning
Fiber positioning and the fusion process run automatically. This assures uniform high quality results independent of the operator. Two mutually independent processes for positioning and automatic splice loss determination have been integrated into the splicer. The time tested LID system (Local Injection and Detection) allows for accurate core-to-core positioning of the fiber ends such that good splicing results can even be achieved with singlemode fibers with eccentric cores. It also allows for the measurement of splice loss at an operational wavelength of 1300 nm. If the LID system cannot be used (e.g. with tight-buffered fibers), the completed splice is analyzed with the L-PAS -video system (Lens Profile Alignment System), and splice loss is indicated in dB as well.

Fiber Requirements: Single and multimode glass fiber with 125 um glass diameter, 250 to 900 um coating diameters
Fiber Display: High contrast 5.5" color LCD
Magnification: Approximately 100 power
Fiber Positioning: Fully automatic in X, Y and Z axes
Mean Splice Loss for Identical, Standard Single-Mode Fibers:
        Multimode fiber: typ. < 0.01 dB
        Standard single-mode fiber: typ. < 0.02 dB
Tensile Test: Automatic / OFF
Splicing Programs: Preset, special and user programs
Video Output: CCIR output (75 ohm)
Mains Power: 95 to 260 V with automatic voltage range selection, 50 - 60 Hz, max 100 VA
External 12 V Power Supply: 12 - 14.5 V, max. 5 A, pole reversal protected
Data Memory Capacity: 1000 splice values
Data Output: RS 232 interface with adjustable baud rate
LID System: Wavelength: 1300 nm, temperature compensated
Attenuation Splices: 1 to 10 dB (in steps of 0.1 dB)
Real-Time Clock: Time and date display with battery backup
Operating Temperature: -5° C to +45° C
Storage Temperature: -20° C to +70° C