| Configurations |
SSOCx-L SSOCx-A |
SSOCx-B |
SSOCx-C |
SSOCx-D |
SSOCx-E |
|
Dual DS1 1.5M |
• |
• |
• |
• |
• |
|
Dual DS3 45M |
• |
• |
• |
• |
• |
|
STS-1 52M |
|
• |
• |
• |
• |
|
OC-1 52M |
|
• |
• |
• |
|
|
OC-3 155M |
|
|
• |
• |
• |
|
OC-12 622M |
|
|
|
• |
• |
|
OC-48 2.5G |
|
|
|
|
• |
|
Dual Wavelength |
|
|
|
|
• |
|
DS1/DS3 Pulse Mask |
• |
• |
• |
• |
|
A single solution for protocol analysis and physical layer
troubleshooting– The SunSet OCx
As telecommunications networks expand to higher bandwidths and wider arrays
of services, it becomes more and more difficult to properly install, maintain,
and troubleshoot them. A typical technician may be responsible for turning up
and integrating many different services, requiring a host of skills, training,
and equipment.
In addition, the modern access network combines many independent physical and
protocol layers. A single voice or data connection may span the networks of
several different companies including Regional Bell Operating Companies (RBOCs),
Incumbent and Competitive Local Exchange Carriers (ILECs and CLECs), and other
private and public networks.
The Challenge– comprehensive access network testing
The SunSet OCx is the latest generation of access network test sets from
Sunrise Telecom, the industry leader in design and manufacture of handheld
telecommunications service verification equipment. It offers DS0 to OC-48
testing, along with all the service verification tools you need, including ATM,
GR-303, Voice, and ISDN PRI. Technicians can increase efficiency, consolidate
training, and save time and money by testing all these rates and services with a
single handheld unit. Among handheld test sets, only the SunSet OCx has the
feature set to ensure quality connections across the entire Access Network.
A complete kit of powerful protocol analysis tools– in one handheld
unit
Incorporating the most popular and powerful features for testing T-carrier
(T1 and T3) and Synchronous Optical NETworks (SONET), the SunSet OCx is also a
full-featured protocol analyzer. The SunSet OCx analyzes Internet Protocol (IP),
Asynchronous Transfer Mode (ATM), Primary Rate Integrated Services Digital
Network (ISDN PRI), Bellcore GR-303-CORE, Frame Relay, and Signaling System 7
(SS7), as well as traditional voice frequency (VF) and trunk conditioning
functions.
The SunSet OCx is battery powered and field upgradeable. Its light weight,
durability, long battery life, and low cost make it the ideal tool for field
technicians in the Access Network. The comprehensive measurements and advanced
features are also well-suited for central office and laboratory
environments.
Power to grow
The SunSet OCx has the flexibility to grow as your network grows. If you only
require DS3 and DS1 testing today, you can add SONET testing later with an easy
software upgrade. Add features like ATM and GR-303 when you need them.
Easy to use
The OCx has a high-contrast color, backlit display and well-organized
measurement screens that allow for quick access to all test results. The
dual-state LEDs give unambiguous alarm and error information. The measurement
screens collect all the important data at a glance; the dynamic summary screen
provides an upto- the-moment summary of all errors and alarms. Intuitive menus
and function keys allow technicians to configure the test set quickly. The AUTO
key simplifies test setup.
Basic Testing Features
- BERT up to 2.5 Gbps
- Bidirectional DS1 drop/insert
- Loopback and span control
- VF/DS0 and fractional T1
- Full complement of test patterns
- Error injection & alarm generation
- 16 MB data storage
Advanced Testing Tools
- Mux/Demux Testing & Emulation
- Pulse Mask Analysis
- SONET Overhead Control
- DS3 FEAC & C-bit Monitoring
- DS1 Data Link
- Remote Control
Protocol Analysis/Emulation
- ATM/IP
- VF Dialing
- ISDN PRI
- GR-303
- SS7
- Frame Relay
Advanced SONET tranmission testing & analysis–in a
handheld
Don’t let its size fool you—the SunSet OCx offers extensive features for
SONET testing and analysis. With the SunSet OCx, operators can access the SONET
network at the optical or electrical interface, including STS/OC-1, OC-3/3c,
OC-12/12c, and OC-48/48c. It supports mapping for DS3, DS3/DS1 and VT1.5.
Comprehensive SONET errors and alarms are conveniently sorted by near-end and
far-end, section, line, and path, complying to Bellcore GR-253. Tests range from
simple verification of power level & frequency for efficient field
installation and maintenance, to advanced features like overhead control/decode
and multiplex testing.
SONET for the field
Lightweight, handheld, and ruggedized, the SunSet OCx is uniquely suited for
field applications. The OCx gives you long battery life and a color display that
is easily readable under all lighting conditions, indoor and outdoor. The OCx
has the power and features you would expect from a benchtop box in a platform
you can take anywhere.
Applications for the field technician:
- Verify network continuity
- Easily detect SONET errors and alarms with LEDs and well-organized results
screens
- Monitor pointer movement in the network or adjust the pointer values to
stress network elements
APS Timing Automatic Protection Switching is an
important, mission-critical function o SONET. The SunSet OCx allows you to
qualify this vital system by measuring the time it takes for a working circuit
to switch to the protection circuit. The user can select the desired switch and
gate times and the OCx will give a clear pass/fail indication along with the
time measurement.
- Sensors and Switching Criteria:
- Line and Path AIS
- Line Parity Errors (B2)
- DS3 Errors
The SunSet OCx also measures the duration of service disruptions & loss
of pattern with millisecond resolution.
SONET Overhead Control Nearly five percent of the SONET
frame is dedicated to overhead. This overhead includes important network
properties such as parity (B1, B2, B3, and VTBIP-2), protection switching (K1,
K2), pointers (H1-H2), network status (S1, G1, V5), and defects (AIS, RDI, REI,
etc.).
The SunSet OCx gives you easy access to the entire section, line, path, and
virtual tributary path overhead, displaying the hex values and their decodes.
The OCx also provides control of transmitted overhead bytes, pointer values, and
pointer movement.
SONET Overhead Highlights
- Decode/encode of overhead bytes
- Display & modify traces (J0, J1, J2) as text characters
- Data Communications Channel (D1-D3, D4-D12)
- VT1.5 overhead control (V1-V5, J2, etc.)
Comprehensive T-Carrier Testing
Just because the SunSet OCx is designed for high speed optical rates and
data-centric protocols like ATM does not mean that you need to sacrifice the
traditional T-carrier applications. In fact, the SunSet OCx offers all the
transmission testing applications for T1 and T3 circuits.
Loopback Control Loopback testing is a vital tool for
circuit turn-up and troubleshooting. The SunSet OCx provides a variety of
options for looping DS1 and DS3 circuits, allowing technicians to isolate a
fault quickly from a single location, saving time and truck rolls.
- In-band and data link codes
- Addressable repeaters (Westell/Teltrend)
- HDSL loopbacks
- DS3 and DS3/DS1 FEAC codes
- Easy-to-read diagrams
The OCx can also emulate CSU or NIU equipment and respond to loopback
commands.
DS1 Testing Features The SunSet OCx comes standard with a
variety of easy-to-use tools for testing DS1 networks.
- View Received Data shows all 24 timeslots over 20 DS1 frames—ideal for
seeing in-band alarms and messages, identifying an ISDN D-Channel, or looking
at simple test patterns.
- Quicktest I/II allows a technician to program a variety of test patterns
for a set duration. At the end of the test, the OCx provides the test results
for each pattern as well as a clear pass/fail indication. Quicktests can also
automatically loop up and loop down the circuit.
- Bridge Tap Detect uses specialized test patterns to determine if bridge
taps are on the line.
- Propagation Delay provides the roundtrip delay of a test pattern through
the DS1 network.
Pulse Mask Analysis The pulse mask feature gives you a
quick and powerful tool to analyze and qualify a DS1 or DS3 circuit. Physical
layer problems become readily apparent, making for quick fault diagnosis.
The SunSet OCx measures the shape and key parameters of the pulse, displaying
the pulse on the screen. The OCx then compares the shape to predefined templates
based on governing standards and provides an easy-to-interpret pass/fail
test.
DS1 Data Link Monitoring the DS1 Data Link is an
excellent way to discover errors which otherwise could not be detected at your
monitoring point. Decodes of bit messages provide valuable information such as
alarms and protection switching. Performance reports provide a comprehensive
snapshot of the health of the circuit.
The SunSet OCx monitors and decodes both bit and performance report messages.
The OCx also transmits bit codes selected by the user or performance reports
compiled from its own measurement results.
DS3 FEAC Monitor and transmit messages carried by the Far
End Alarm and Control Channel used in C-bit framing to provide circuit status
and loopback control.
ATM Features
The SunSet OCx is the single testing solution for both the physical layer and
the ATM layer. With one test set, a single technician can verify network
performance with and without ATM traffic. All applicable network rates from T1
to OC- 48c are available in one chassis, eliminating the need for multiple ATM
test sets. The full-featured ATM testing capabilities of the SunSet OCx provide
the power and flexibility to install and troubleshoot an ATM network from the
ground up. The OCx can test and monitor transmission between separate network
elements (NNI) or between the network and edge devices. Here it can verify
network provisioning; perform stress tests; conduct BER testing; and monitor
responses to alarms, errors, and OAM cells. The SunSet OCx allows you to
nonintrusively monitor traffic across the network, gathering statistics on
congestion, bandwidth, idle cells, OAM cells, and errors.
Any SONET or T-carrier network provisioned for ATM traffic needs to be
qualified for ATM. If you lease your network to service providers using ATM, you
need a tool to test, verify, and troubleshoot the network and the traffic it is
carrying. Conversely, if you are responsible for the ATM traffic, you must
verify that the network is error-free and functioning properly, especially when
you do not own the network. When traffic is disrupted, you cannot waste valuable
time and money on finger pointing.
Traffic Generation
- Generate multiple independent VCCs. With the SunSet OCx, you can program
up to eight independent VCCs, each with their own traffic pattern and payload,
up to 100% of your ATM network capacity. The OCx supports O.191 test cells or
user cells with pseudo-random or 16-bit patterns.
- Insert Errors and OAM Cells. Inject bit errors, HEC errors, or OAM Fault
Management cells into your generated traffic.
Traffic Supervision
- VCC Scan. View the traffic moving across the network including the cell
header and bandwidth. Filter on VPI or select one or more VCCs for more
detailed traffic statistics.
- BERT and Quality of Service (QoS). The SunSet OCx supports QoS
measurements, such as cell delay variation, cell loss ratio, and bit error
rate testing.
- Capture and store cells. Save, view, decode, and analyze user and OAM
cells. Decode the ATM header and OAM function fields.
DSL Testing Highlights
- Automatic detection of SunSet xDSL
- Independent upstream and downstream rates
- Bit error rate and throughput testing
- ATM over SONET and T-Carrier out of the DSLAM
DSL Testing
As DSL becomes widely deployed, DSLAM (Digital Subscriber Loop ATM
Multiplexer) installation verification is becoming more critical in ensuring
proper functionality. However, when the full backbone is not operational, only
limited testing can be achieved. To solve this problem, Sunrise Telecom has
developed an innovative test solution for DSLAM turn-up verification.
The SunSet OCx works hand-in-hand with the SunSet xDSL to perform dualended,
asymmetric ADSL qualification. These tests not only allow you to verify
installation, but also the qualification of the Optical Carrier and the DSL
copper pair simultaneously. This help qualify DLC (Digital Loop Carrier) Systems
and verify proper provisioning of the remote DSLAM.
ATM IP Testing
The predominant application for ATM networks, especially for DSL services, is
the Internet. Testing the IP layer is critical for qualifying an ATM connection.
Though it only takes a few minutes, the IP PING test can qualify not only the
ATM network, but reach through Ethernet, Packet over SONET, and other IP-centric
networks.
ATM/IP Testing Highlights
- RFC 1483 Bridged and Routed, PPPoA, and P PoE
- Static and dynamic addresses
- PING generation and automated PING response
Powerful signaling and protocol analysis in your hand
VF/DS0 Testing The SunSet OCx contains complete
diagnostic tools necessary to install and troubleshoot voice circuits. Full
duplex drop and insert testing allows the user to place a call on one channel
while the T1 remains in service. Verify and monitor service, signaling, digits,
and noise level. You can also check the voice path with the integrated
microphone and speaker or handset. Full physical layer results allow
transmission verification while measuring signal levels and error or alarm
conditions.
VF/DS0 Highlights
- Full duplex drop and insert testing
- Talk/listen or send/receive test tones
- E&M, loop-start and ground-start with FXO/FXS
- Dialing: DTMF, MF, pulse
- Digit capture and analysis
- Scan mode for receiving calls or digits
- Noise Measurements: S/N, 3k-flat, Cmessage, C-notch
- Monitor calls: voice, signaling sequences with timestamps
ISDN PRI PRI trouble can be caused by a variety of
sources such as physical layer errors, timing, switch translations, and protocol
problems. A PRI test set that combines full-featured T1 and PRI testing lets you
identify trouble the first time to avoid costly revisits. The SunSet OCx’s ISDN
Primary Rate option rivals protocol analyzers and equipment dedicated solely to
PRI testing. You can use the OCx to install new PRI circuits or PBX equipment by
placing/receiving voice and data calls. Talk/listen and BERT testing verify the
B-channel connection. Inservice monitoring can troubleshoot problems with a full
D-channel decode, message filters, and storage.
ISDN PRI Highlights
- TE/NT Emulation
- National ISDN, AT&T, and Nortel DMS
- 23B+D, 47B+D, or 46B+2D testing
- Talk/listen for voice calls: Standard, 3.1k
- BERT data calls: 56k, 64k, Nx64k
- Backup D-channel test for NFAS circuits
- D-channel monitor with full decode
- Trace filtering and storage
GR-303 The increased deployment of GR-303-based DLCs and
access devices creates new provisioning challenges and troubleshooting problems.
The SunSet OCx meets these new testing challenges for all aspects of GR-303
systems: monitoring the TMC/CSC control channel, viewing robbed ABCD signaling
and dialed digits, listening to voice channels, and thoroughly testing the
physical layer. The GR-303 option troubleshoots signaling problems between the
switch and remote terminal. You can determine call status, monitor dropped
calls, detect abnormal conditions, and identify when service was
unavailable.
GR-303 Highlights
- Bidirectional monitoring of TMC/CSC/EOC
- Full L3 decode of TMC/CSC messages including message type, customer, DS1#,
DS0#, and cause values
- Full L7 decode of eoc channel including ROSE & CMIP protocols
- Quick summary of any abnormal or invalid conditions via a statistics
screen which displays channel unavailability, protocol problems, or ring
failure
Signaling System 7 The SS7 option places powerful SS7
protocol analysis and monitoring in the hands of the field technician. Protocol
decodes help technicians determine a preliminary diagnosis to SS7 network
problems. Statistics screens show traffic utilization, frame types, and
retransmission. Powerful filters aid in quick troubleshooting by focusing on a
specific customer, message type, OPC/DPC, etc.
SS7 Highlights
- Protocol analysis for SS7 TUP, ISUP, SCCP, SNM, & SNT messages
- TCAP filtering, capturing, & decoding of Transaction, Dialog, and
Component Portions
- Capture layer 1 events (alarms)
- Capture and decode layer 2 , 3, and 4 protocol messages\
Frame Relay features
The Frame Relay option adds powerful frame relay testing to the SunSet OCx’s
thorough physical ayer testing, providing the perfect solution for installing
and maintaining frame relay networks running over a T1 interface. Complete
physical layer testing, along with frame level simulation and analysis, is
essential, since frame relay lacks its own error checking capabilities. The
SunSet OCx provides the fastest method for verifying performance and maintaining
quality of service in frame relay networks.
- In-service monitoring: In-service monitoring provides vital statistics on
frame relay performance: utilization percentage, throughput (max, min, avg),
and frame size. It also gives essential troubleshooting results for
congestion, aborted frames, short frames, discarded frames, and FCS (frame
check sequence) errors.
- IP PING: The IP PING feature tests connectivity all the way to the user's
IP LAN connection. Results include the number of errored or unreached PINGs
and the round trip return time.
- FOX Testing (Stress Testing): The SunSet OCx's load generation feature is
capable of stress testing the network's various frame loads. This ability to
generate traffic helps determine if the CIR (committed information rate) is
achieved.
Remote Control You can control the SunSet OCx remotely
from your Windows® PC over a dial-up, IP, or serial port connection. The remote
control user interface duplicates the look and feel of the OCx, requiring no
extra training. VT100 terminals and terminal emulators can also control the OCx
through a standard printer cable and null modem adapter. All test set LEDs and
keys are represented.
Data Storage The SunSet OCx comes standard with a data
storage PC card with 32 Mb of memory – enough space to hold hundreds of protocol
traces or thousands of test results. All the traces and results appear as text
files organized into separate folders. Simply load the files into a spreadsheet
for analysis or into a word processor to create reports.
Auto Configuration With a single button, the SunSet OCx
will automatically configure itself to the circuit under test. The OCx will find
the proper rate, mapping, framing, and test pattern based on the signal it
receives.
Graphic Display Navigating the SunSet OCx is
straightforward with an icon-based main menu. The graph screen shows the test
set configuration using familiar multiplexer icons, clearly showing the
transmitted and measured signals.
Status and Event Record All important defects, errors,
and alarms are constantly logged with a date and time stamp. The event log is
always one button away for quick reference. Save the record to the storage card
or print it out.
|