The TV90 is designed for ease-of-use. You'll spend less time operating the
TDR and more time repairing faults. Simply select the cable type to be
tested and the TV90 does the rest. Impedance, VP, gain, pulse width and
vertical position are automatically selected and adjusted as you scan the cable.
Just move the cursor to the fault to pinpoint its location.
On the performance side, the TV90 employs optimized pulsing and sampling
coupled with advanced filtering and signal processing techniques to ensure the
maximum measurement rante. That way, you'll always have a clean waveform for
easier fault interpretation.
Short Pulse Width The TV90 provides a 5 ns pulse width
for close-in resolution. Faults as near as 3 ft. from the pedestal can be
located with ease.
Rugged Package Best of all, you get all this performance
in a rugged handheld TDR package. Come snow, rain, heat and humidity, the TV90
keeps working, because you have to.
Features:
- Find Location of Damage In Drops
- Find Impedance Mismatches
- Locate Bad Passive Devices
- Determine Length of Cable
- Large, High-resolution, Backlit Display
- Splash, Dust and Shock Resistant Packaging
- Easy to Use - Anyone Can Use It
- One Button Expand/Full-view Function
- 75 Ohm F Connector
- Intermittent Fault Location
- Context-sensitive Help (Help Screens Available for All Functions)
- Small, Portable, Lightweight Package (2.2 lbs.)
- Accurate (±2 ft. up to 200 feet, 1% beyond)
- 4000-Foot Fault-location Capability
- Internal Cable Types for Fast, Accurate Testing
Specifications:
|
Test Signal Output |
1/2 sine. |
|
Amplitude (into 75 Ohm) |
6 ns pulse: 5 V. - 12 ns pulse: 6 V. |
|
Pulse Widths |
6 and 12 ns. |
|
Output Impedance |
75 Ohm |
|
Input protection |
200 V, DC + peak AC to a maximum of 440 Hz, 30 second
duration |
|
Display Ranges |
Eight automatic display ranges |
|
Gain |
0 to 63 db |
|
Filter |
High pass, cutoff frequency 150 kHz, plus averaging |
|
Distance Accuracy |
0 to 200 ft: ±2 ft . Beyond 200 feet: 1% + zero offset.
|
|
Display - |
Resolution: 520 x 200 pixels. Size: 5.25 inches. Type: high
contrast LCD. Backlight: operator switchable. |
|
Distance Measurements |
Meters, feet, nanoseconds. |
|
Auto Shutoff Time |
Operator selectable: 5 to 30 minutes. |
|
Temperature Range |
Operating: 0°C to +45°C. Non-operating: -20°C to +60°C |
|
Humidity |
Operating: 95% RH, noncondensing at +30°C to +40°C. |
|
Field Usage |
Shock, splash and dust resistant. |
|
EMI Emissions |
EN55011, Class A. FCC Part 15, Subpart B, Class A. |
|
Battery Operation - |
Battery Type: Six AA alkaline. Operating Time: Over 4.5 hours
with backlight off. |
Includes:
- Tempo TV90 CableScout Time Domain Reflectometer
- BNC F To Alligator Clips
- BNC Male To Female Converter
- Coax Cable
- DC Car Charger For Battery Charger
- THM5CHG TEKmeter Battery Charger w/ Manual
- Battery Pack
- AC Adapter/Charger
- Carrying Case For Unit
- Hard Copy User Manual
- Original Factory Box
|