Fluke 99B II kit with accessories

Fluke 99B 100MHz 2CH 5GSa/s Scopemeter

Fluke 196B kit with accessories

2 Fluke 196B ScopeMeter Handheld Oscilloscopes

2 Fluke 199 ScopeMeter 200 MHz Oscilloscopes

$0.00
Availability: Out of stock
SKU
11H45

Condition: Refurbished / Calibrated

Warranty: 90 Day Exchange

Request a Quote for

Have Questions or doubts? Submit the following request and expect our detailed quote within 24 hours!

we are commited to win your business!

ScopeMeter® 190 Series : All this power in your hand! 

The ScopeMeter 190 Series has specifications you typically only find on high-end bench oscilloscopes. They offer up to 200 MHz bandwidth for capturing high frequency signals, as found in todayメs state-of-the-art electronics, 2.5 GS/s real-time sampling and advanced memory and triggering functions. Theyメre rugged, compact and battery powered.

General Features:

  • Dual-input - 200, 100 or 60 MHz bandwidth
  • Up to 2.5 GS/s real-time sampling per input
  • Choice between a high resolution Color display (190C Series) or Black & White display (190B Series)
  • High waveform resolution of 3,000 datapoints per channel (NEW)
  • Connect-and-Viewル automatic triggering and a full range of manual trigger modes
  • Frequency Spectrum Analysis using FFT (190C) (NEW)
  • Digital Persistence for analyzing complex dynamic waveforms like on an analog scope
  • Fast display update rate for seeing dynamic behavior instantaneously
  • Automatic capture and replay of 100 screens
  • 27,500 points per input record length using ScopeRecordル mode
  • TrendPlotル paperless chart recorder for trend analysis up to 22 days
  • Up to 1000 V independently floating isolated inputs
  • Waveform reference for visual comparisons and automatic pass/fail testing of waveforms
  • Vpwm function for motor drive and frequency inverter applications.
  • 1000 V CAT II and 600 V CAT III safety certified
  • Four hours rechargeable Ni-MH battery pack

See whatメs really happening

With a maximum real-time sampling rate of 2.5 GS/s per input, you can see what really happens, with 400 ps resolution. Both inputs have their own digitizer, so you can simultaneously acquire two waveforms and analyze them with the highest resolution and detail. If an anomaly flashes by on the screen, just press the Replay button to see it again. And thanks to the wider screen, you will always see a 12 divisions time-window ヨ giving a far better overview of whatメs happening both before and after the trigger event!
Deeper waveform acquisition memory (NEW)

The waveform memory of all oscilloscopes in both the 190B and 190C Series has been enlarged to allow as many as 3000 samples per channel to be acquired. This is 1800 samples more than before, giving much greater waveform resolution. You can use the ZOOM function to find tiny details in a long waveform, for example, the color burst in a video signal or a single impulse in a complex data-stream. All models also allow the high-resolution waveforms to be transferred to a PC for later detailed analysis using FlukeView ScopeMeter software.
Easier identification of traces, everywhere

The full-color display makes identification of individual waveforms easier, particularly when displaying large amplitude or multiple overlapping waveforms on screen. On-screen color labels, measurements and warnings are clearly linked to specific waveforms. The bright, high contrast display allows for clear reading under varying light conditions. And still a 4 hour battery operation time is assured!
See dynamic signal behavior instantaneously

The Digital Persistence uses multiple intensity levels and user selectable decay time -itメs as if youメre looking at the display of an analog, real time oscilloscope! The fast display update rate thatメs a standard on all models reveals signal changes instantaneously, useful for instance when making adjustments to a system under test.
Advanced trigger modes

A wide choice of automatic and manual trigger modes gives you the flexibility to capture just about any signal youメll encounter. Connect-and-Viewル triggering is ideal for fast and easy checking of multiple test-points. The manual modes include time delay, video and pulse-width triggering. A fully isolated external trigger input is included for troubleshooting time relationships between two input signals synchronized to a third signal.
(NEW)

Two new modes ヨ ムn-cycle triggeringメ and ムdual-slope triggeringメ ヨ have been added to the Fluke 190C Series to help you isolate the phenomena of interest. N-cycle triggering ensures you get a stable ムliveメ image of a signal, for example, in frequency dividers and clocked (synchronous) digital systems, or to synchronize on bursts of pulses. Dual-slope triggering enables the oscilloscopes to trigger on both rising and falling edges alike. This means that any edge in the signal will act as trigger event and initiate a new waveform acquisition, a most useful capability when making eye-patterns from digital data-streams, or in conjunction with single-shot phenomena.
Automatic capture and replay of 100 screens

Scope users know how frustrating it is to see a one-time anomaly flash by, never to be seen again. Not with the ScopeMeter 190 Series! Now you can look back in time with a touch of the replay button. In normal use, the instrument continuously memorizes the last 100 screens. Each time a new screen is acquired, the oldest is discarded. At any moment you can モfreezeヤ the last 100 screens and scroll through picture-by-picture or replay as a ムliveメ animation. Cursors can be used for further analysis. Or you can use the advanced trigger capabilities to capture up to 100 specific events. Two sets of 100 captured screens with individual time stamps can be stored for later recall or download to a PC.
Deep memory for high-resolution ScopeRecordル

The ScopeRecord memory stores 27,500 points per input or more, for high resolution recording of events up to 48 hours, and captures fast intermit-tents and glitches as short as 50 ns. This continuous roll mode stores, for example, events like motion profiles, UPS-, power supply- and motor start-ups. All models also have a ムStop-on-Triggerメ in the ScopeRecord mode. This allows the ScopeMeter to store waveform data until the instrument is triggered or until a repetitive trigger signal is interrupted. This way, the instrument will, for example, automatically recognize a power failure and store the waveform data preceding it. And with 100 x zoom, you can look at the smallest details, like individual power cycles. Two of these 27,500 point recordings can be stored for later analysis.
Measure from mV to kV ヨ fully isolated and safely!

The ScopeMeter 190 Series have three independently floating isolated inputs. While conventional oscilloscopes can only make measurements referenced to the line power ground, measurements on each of the Fluke ScopeMeter 190 Series inputs can be referenced to a different "low" level. This enables measurements in mixed circuits having different ground references, and also eliminates the risk of accidental ground short circuits. All inputs are safety certified for measurements in 1000 V CAT II and 600 V CAT III environments. And the standard probes cover a wide application range from mV to kV, making the ScopeMeter 190 Series ideal for micro-electronics to electrical power applications.
Analysis power

For analysis of waveforms, ScopeRecord and TrendPlot recordings, the ScopeMeter 190 Series feature 30 automatic measurements, plus cursors, zoom and a real-time clock. The analysis can be made directly or later when back in the office. Up to 2 recordings and 10 scope screens can be stored for analysis, print-out or download to a PC.
Frequency Spectrum Analysis (NEW)

All 190C Color ScopeMeters now include Frequency Spectrum Analysis functionality based on Fast Fourier Transformation (FFT) analysis as a standard feature. This makes it possible for you to identify the individual frequency components contained in a signal. The spectrum analysis function is also handy to reveal the effects of vibration, signal interference or crosstalk. An automatic window function assures optimal windowing, although you may manually select your preferred time window.
Waveform Pass / Fail Testing

ムWaveform referenceメ allows an acquired trace to be stored and designated ムreference traceメ for visual comparisons, or it can be used as the reference for automatic ムPass / Failメ testing (190C). Up to 100 individually matching (ムPassメ) or non-matching (ムFailメ) waveforms can be stored in the replay memory, allowing you to monitor your systemメs behavior over a long period of time, without the need for you to attend!
Cursor-limited automatic measurement (NEW)

Automatic power and Vrms-measurements can now be performed on a specific, user identified portion of the waveform using the cursors of the Fluke 190C to define the time-window of interest. In this way, the Color ScopeMeter can measure the power within a specified time span, or the rms-value of a voltage during a dedicated period of time.
... and there is more
  • Variable gain on channel A helps you compare signals on the two inputs. All inputs are safety certified for measurements in 1000 V CAT II and 600 V
  • The Vpwm measurement is for measuring the effective RMS output voltage of variable speed motor drives and frequency inverters.
  • Medical applications: For use on Medical Imaging Equipment and on High-Resolution Video systems, an optional instrument configuration is available for the Fluke 190 Series that supports measurement of

Use TrendPlotル to help find intermittents, fast

The toughest faults to find are those that happen only once in a while: intermittents. They can be caused by bad connections, dust, dirt, corrosion or simply broken wiring or connectors. You may not be around to see it - your Fluke ScopeMeter will. In this "paperless recorder" mode, you can plot the minimum and maximum peak values and average over time - up to 22 days. The two inputs can plot any combination of voltage, current, temperature, frequency and phase - with time and date stamp -to help lead you to the cause of those faults quickly.
FlukeView® Software for documenting, archiving and analysis FlukeView® for Windows® helps you get more out of your ScopeMeter by:
  • Documenting - transfer waveforms, screens and measurement data from the ScopeMeter to a PC. Print or import the data into your report
  • Add user text to individual ScopeMeter settings - providing guidance to the operator when recalling a set-up.
  • Archiving - create a library of waveforms with your comments for easy reference and comparison. Store complete Replay cycles for analysis of waveform changes. Store complete memory content of the Scop
  • Waveform Compare - store reference waveforms on the PC, or send a reference back to the ScopeMeter for waveform comparison and "Pass/Fail" testing.
  • Analysis - use cursors, perform spectrum analysis or export data to other analysis programs. ScopeMeter test tools are connected to a PC via an optically-isolated RS-232 interface cable.

Specifications

Bandwidth: 200 MHz
Real-time sample rate: 2.5 GS/s
Inputs and digitizers: 2 plus external / DMM input  
Independently floating isolated inputs: Up to 1000 V between inputs, references and ground 
Timebase range: 5 ns - 2 min/div; 10 ns - 2 min/div (192B) 
Input sensitivity: 5 mV-100 V/div 
Glitch capture: 50 ns (5 µs/div - 1 min/div) 
Scope measurements: Cursor: 7; Automatic: 30 
Maximum record length: ScopeRecord mode: 27,500 pts per input; Scope mode: 3,000 pts per input 
Memory: Screens: 10; Setups: 10 
Display: 144 mm full monochrome LCD with fast update rate





For full Fluke 199 specifications, please click here: Fluke 199

2 Fluke 199/003 ScopeMeter, 2.5GS/s Dual-Input 200MHz Oscilloscopes

With a maximum real-time sampling rate of 2.5 GS/s per input, you can see what really happens, with 400 ps resolution.

Includes 2 Carrying Cases & Accessories As Listed!

Fluke 199 Scopemeter 199-Scopemeter Handheld Oscilloscope Models On Sale Warranty Calibration Backed by The Best Service and Lowest Prices in the Industry.

 

  • (2) Fluke 199 ScopeMeter 200MHz Oscilloscopes
  • (4) 10:1 250MHz Voltage Probes
  • 1000V Hard Point Test Leads (2 Red, 2 Black)
  • (2) AC Adapter/Chargers
  • Flukeview Scopemeter Software SW90W
  • User Manual On CD-ROM
  • (2) Carrying Cases