3M Dynatel 965DSP Subscriber Loop Analyzer w/ TDR
Condition: Refurbished / Calibrated
Warranty: 1 YEAR WARRANTY
Shipping: USA & Worldwide
- 3M Dynatel 965DSP Subscriber Loop Analyzer Version 7.00.9 w/ Option: (BC# 42276-L/T*)
- TDR:
- Single Trace
- Dual Trace
- Differential
- Crosstalk
- Memory
- Peak
- TDR:
- Test Lead Set (Red/Black, Blue/Yellow, Green)
- AC Adapter/Charger
- User Manual on CD-ROM
- Carrying Case w/ Strap
The 3M Dynatel 965DSP Subscriber Loop Analyzer is a microprocessor-controlled integrated test set that provide full-featured POTS and fundamental ISDN testing. The functions include fault location and repair verification on twisted-pair, quad and coaxial cable (utilizing capacitance bridge, resistance bridge and Time Domain Reflectometer (TDR) functions).
TDR ? full-featured TDR with user-selectable pulse widths, length, gain zoom, filter and Vp. Four modes of operation:
- Single trace ? provides graphical representation of events on a pair.
- Dual trace ? allows active comparison of two traces.
- Differential ? displays difference between two circuits.
- Crosstalk ? displays the crosstalk from one pair to the other.
|
TDR
Ranges Pulse width Velocity input Modes |
3 ft?300 ft, 20 ft?1,000 ft, 50 ft?3,000 ft, 150 ft. 10,000 ft, 450 ft?30,000 ft (0?100 m, 5?300 m, 15?1,000m, 45?3,000 m, 140?10,000 m) 5 nS, 34 nS, 235 nS, 1600 nS 0.50 to 0.99 (150 to 299 uS/m) Single trace, dual trace, differential, memory, crosstalk |
1 ft (1 m) Fixed values 0.01 (1 uS/m) ? |
0.6% range ? ? ? |
The Dynatel 965DSP subscriber loop analyzer executes a wide range of individual tests, or performs automatic test routines as specified by the user to categorize and sectionalize problems. Specific tests and measurements performed by the unit include:
- Voltage ? detects and measures the presence of exchang or foreign DC or AC voltages.
- Tone ? provides a test tone for conductor identification; user-selected tones from 1 to 40 kHz for transmission measurements.
- Current ? measures DC loop current.
- Ohms ? measures conductor and insulation resistance u to 1000 megohms.
- Resistance fault location ? displays distance to fault.
- Opens ? locates opens at distances up to 100,000 ft. (30 km).
- Splits ? locates splits on paired cable.
- Ringer count ? counts the number of ringers on a particular loop.
- Load coil count ? indicates the presence of load coils in loop circuit.
- Wideband loss ? loss measurements to 200 kHz for pre-qualifying ISDN and HDSL.
- Loss ? measures voice band loss.
- Noise ? measures noise metallic and noise to ground in dBrnc.
- Longitudinal balance ? provides active measurement of line balance.
Flexible, practical features
The 965DSP subscriber loop analyzer is designed for functionality and ease of use. Features of the unit include:
- IR port - infrared port for downloading future software programs.
- Self-calibration ? internal instrument calibration and setup procedures.
- Graphical user interface ? user-friendly, icon-based display of test results.
- Replaceable five color-coded banana jacks for test connections.
- HELP function ? an internal help menu provides information as needed during operation.
- Telephone ? internal telephone or ?talk set.?
- Rechargeable nickel metal hydride batteries ? with battery charger, plus alkaline battery holder.
- Modular hardware and software design ? for easy upgrades, investment protection.
- Backlit high resolution/high contrast LCD display.
The Dynatel 965DSP test sets are housed in a lightweight, ergonomically designed case for portability and ease of use. The units are weather resistant and weigh only three pounds.
Dynatel 965DSP Specifications:
| ANSI/ITU Standards Supported | ITU G.992.2 (G.Lite), ITU G.992.1 (G.DMT), ANSI T1.413 Issue 2 |
| ADSL Modes | ANSI, G.DMT, G.Lite, MultiMode |
| Reach | Designed to synchronize at distances from 0 ft. to 18,000 ft. |
| Statistics | Actual and maximum upstream and downstream connect rates |
| Upstream and downstream percent used ADSL line capacity | |
| Upstream and downstream noise margin | |
| Upstream and downstream signal attenuation | |
| Upstream and downstream power levels | |
| Modem manufacturer identification | |
| Upstream and downstream FEC, CRC, and HEC counts | |
| Alarm codes including LOS, LOF, LCD and LOM | |
| Graphical display of bits-per-bin count for the DMT signal | |
| Operating Modes | Captured Modem auto-disconnects from the far-end after statistics gathered |
| Continuous Modem gathers statistics for up to two minutes |
Electrical Specifications
| Main Functions | Range | Resolution | Accuracy |
| Voltage (DC) | 0 to 99.9 V 100 to 300 V | 0.1 V 1 V | 1% ± 0.5 V 3% |
| Voltage (AC) | 0 to 99.9 V 100 to 250 V | 0.1 V 1 V | 1% ± 0.5 V 3% |
| Current | 0 to 59.9 mA 60 to 110 mA | 0.1 mA 0.1 mA | 1% ± 0.3 mA 2% |
| Resistance (DC) with CO voltage | 0 to 9999 O 0 to 9999 O 10 k to 99.9 kO 100 k to 999 kO 1 M to 9.9 MO 10 M to 99 MO 100 M to 990 MO |
1 O 1 O 0.1 kO 1 kO 0.1 MO 1 MO 10 MO |
1% ± 5 O 1% ± 50 O 1% 3% 3% 5% 10% |
| Opens (no noise) | 0 to 3,000 ft (0 to 1000 m) 3,000 to 10,000 ft (1 km to 3 km) 10,000 to 50,000 ft (3 km to 15 km) 50,000 to 100,000 ft (15 km to 30 km) |
1 ft (1 m) 1 ft (1 m) 10 ft (10 m) 100 ft (100 m) |
1% ± 3 ft 3% 5% 10% |
| RFL Fault range Resistance to fault (no noise) |
0 to 20 MO 0 to 99.99 O 100 to 999.9 O 1 kO to 7 kO |
? 0.01 O 0.1 O) 1.0 O |
? 0.1% of RTS ± 0.01 O 0.2% of RTS ± 0.01 O 1.0% of RTS ± 0.01 O |
| Loss (& frequency) | -40 to +10 dBm, 200 to 3000 Hz -40 to +10 dBm, 3000 to 9995 Hz -40 to +10 dBm, 10 k to 19.9 kHz |
0.1 dB, 1 Hz 0.1 dB, 5 Hz 1 dB, 10 Hz |
0.5 dB, 2 Hz 0.5 dB, 10 Hz 1 dB, 20 Hz |
| Wideband loss | -40 to +10 dBm, 20 k to 200 kHz | 1 dB, 100 Hz | 2 dB, 0.1 kHz |
| Noise metallic | 0 to 50 dBrnc (-90 to -40 dBm0p) | 1 dB | 2 dB |
| Noise to ground | 40 to 100 dBrnc (-50 to 10 dBm0p) | 1 dB | 2 dB |
| Longitudinal balance | 62 to 40 dB | 1 dB | 2 dB |
| Tone output ID User defined User defined ISDN |
200 to 1000 Hz, fixed level 200 to 9995 Hz, -20 to +1 dBm 10 k to 19.99 kHz, -20 to +1 dBm 40 kHz, +6 dBm fixed level |
1 Hz 1 Hz, 0.1 dB 10 Hz, 1 dB ? |
1% 1% Hz, 0.2 dB 2% Hz, 1 dB 2%, 2 dB |
| Dial mode | DTMF, Pulse | Standard | Standard |
| TDR Ranges Pulse width Velocity input Modes |
3 ft?300 ft, 20 ft?1,000 ft, 50 ft?3,000 ft, 150 ft. 10,000 ft, 450 ft?30,000 ft (0?100 m, 5?300 m, 15?1,000m, 45?3,000 m, 140?10,000 m) 5 nS, 34 nS, 235 nS, 1600 nS 0.50 to 0.99 (150 to 299 uS/m) Single trace, dual trace, differential, memory, crosstalk |
1 ft (1 m) Fixed values 0.01 (1 uS/m) ? |
0.6% range ? ? ? |
| ISDN Link test Error test | Active/inactive Near-end & far-end block errors | ? 1 error | ? 1 error |
| Auto | Same specifications as full tests | See above | See above |
For full 3M Dynatel 965DSP product specifications, please click here: 3M Dynatel 965DSP
Sell Your Equipment
At AAATesters we are committed to helping you maximize the value of your surplus, excess and underutilized Test Equipment. We buy Test Equipment of all makes and models.
If you would like to Sell your Equipment, please submit the Request form below.
Reasons to Sell to Us
• Quick & Easy Process to Sell or Trade Equipment
• Get Cash Today! or Trade-in Credit for New or Refurbished Equipment
• Free Shipping - We will Pay for Shipping to us. We can even setup, pack and pickup the Equipment you are selling to us
• Improve ROI, Operational Efficiency, Budget Management, and Planning of your Future Needs