Fluke 435 II kit with accessories

Fluke 435 Series II Power Quality Analyzer Meter

Amprobe DM-III kit with accessories

Amprobe DM-III Power Quality Recorder

AEMC 8335 PowerPad 3 Phase Power Quality Analyzer

$3,539.00
Availability: In stock
SKU
PQ13

Condition: Refurbished / Calibrated

Warranty: 90 Day Exchange

 AEMC 8335 Power Pad

The PowerPad® Model 8335 is a three-phase power quality analyzer that is easy-to-use, compact and shock-resistant. It is intended for technicians and engineers to measure and carry out diagnostic work and power quality work on one, two or three phase low voltage networks.

The PowerPad®メs 2GB of memory is conveniently partitioned to let you store four different types of data, synchronized or independent of each other. You can store up to 50 screen snapshots, up to 300 captured transients that contain four cycles for each active input, and 10000 alarm events from up to 40 different parameters. You can also record trend data for days, weeks or even months.

Six direct access function buttons quickly let you see:

Waveforms ヨ Display Volts, Amps, THD and Crest Factor by phase or for all phases. You can display all the voltage inputs on one screen, phase-to-phase or phase-to-neutral. Realtime phasor diagrams can be displayed for volts and amps, also by phase or for all phases including phase unbalance.
Harmonics ヨ Display Harmonics out to the 50th for Volts, Amps and VA. Individual Harmonics
are displayed as a percentage and value for Volts, Amps and VA. Harmonic direction and
sequencing can also be displayed.
Transients ヨ Set, capture and display transients. You select the threshold and the number of transients to capture. The PowerPad® then captures four waveforms for each transient; the triggering waveform as well as one pre-triggered and two post-triggered waveforms. As many as 300 transients each consisting of 4 waveforms per channel for up to 8 channels can be captured.
Trend Recording ヨ Record and display trend data at user selectable sample rates from 1/sec to 1/15 minutes and user programmable recording periods into 2GB of memory.

Specifications:
 
Electrical
Sampling Frequency 256 samples per cycle
Data Storage 2GB SD Card
Voltage (TRMS) Phase-to-Phase: 1000V; Phase-to-Neutral: 1000V
Current (TRMS) MN Clamp: 0 to 6A/120A or 0 to 240A SR Clamp: 0 to 1200A
MR Clamp: 0 to 1000AAC, 0 to 1400ADC MiniFlexル: 0.1 to 1000A
AmpFlex®: 0 to 6500A1
MEASUREMENT RANGE RESOLUTION ACCURACY
Single-Phase RMS Voltages 15 to 1000V 0.1V ±0.5% ± 2cts
Phase-to-Phase RMS Voltages 15 to 1000V 0.1V ±0.5% ± 2cts
DC Voltage Component 15 to 1000V 0.1V ±1% ± 5cts
Single-Phase Peak Voltages 15 to 1414V 0.1V < 1000V
1V > 1000V
±(1% + 1V)
Phase-to-Phase Peak Voltages 15 to 1414V 0.1V < 1000V
1V > 1000V
±(1% + 1V)
Frequency (Hz) 40 to 69Hz 0.01Hz ±0.01Hz
Current Probes (Arms)
MN Probe
SR Probe
AmpFlex® Sensor

0 to 240A
0 to 1200A
10 to 6500A

0.1A
0.1A < 1000V; 1A > 1000A
0.1A < 1000V; 1A > 1000A

±(0.5% + 2cts)
±(0.5% + 2cts); ±(0.5% + 1ct)
±(0.5% + 1A)
Active (Real) Power (kW) 0 to 9999kW 4 digits (10,000ct) ±1% ± 1ct @ PF =0.8
Reactive Power (kVAR) 0 to 9999kVAR 4 digits (10,000ct) ±1% ± 1ct @ PF =0.8
Apparent Power (kVA) 0 to 9999kVA 4 digits (10,000ct) ±1% ± 1ct
Power Factor (PF & DPF) -1.000 to 1.000 0.001 ±(1.5% + 10cts)
Active Energy (kWh) 0 to 9999MWh 4 digits (10,000ct) ±1% ± 1ct @ PF =0.8
Reactive Energy (kVARh) 0 to 9999MVARh 4 digits (10,000ct) ±1% ± 1ct @ PF =0.8
Apparent Energy (kVAh) 0 to 9999MVAh 4 digits (10,000ct) ±1% ± 1ct
Unbalance (V & A) 0 to 100% 0.1% ±1% ± 1ct
Phase Angle (VヨA, AヨA, VヨV) -179° to +180° ±2° ± 1ct
Harmonics (1st to 50th)
F = 40 to 69Hz (V = 50V, A > nom/100)
0 to 999% 0.1% ±1% + 5cts
Total Harmonic Distortion (V & A) 0 to 999% 0.1% ±1% + 5cts
K-factor (Akf) 1 to 99.99 0.01 ±5% ± 1ct
Flicker (Pst) 0.00 to 9.99 0.01 -
Power Source 9.6V NiMH rechargeable battery pack
External AC supply: 110/230VAC ±10% (50/60Hz)
Battery Life =8 hrs with display on; =35 hrs with display off (record mode)
Mechanical
Dimensions 9.8 x 7.8 x 2.6" (250 x 200 x 67mm)
Weight 4.3 lbs (1.95kg)
Display
Display Type 1/4 VGA (320 x 240) color LCD
Environmental
Operating Temperature 32° to 122°F (0° to 50°C)
Storage Temperature -4° to +122°F (-20° to +50°C)




For full AEMC 8335 product specifications, please click here: AEMC 8335

AEMC 8335 PowerPad Three-Phase Power Quality Analyzer

Measurement of TRMS voltages up to 1000Vrms AC/DC for two, three, four or five-wire systems

Captures And Records Trend, Transients, Events and Waveforms Simultaneously, With 2GB Of Memory For Data Storage

Includes Carrying Case & Accessories As Listed

AEMC 8335 AEMC-8335 Power Quality Analyzer Models On Sale Warranty Calibration Backed by The Best Service and Lowest Prices in the Industry.

BC# 29550

  • AEMC 8335 PowerPad Three-Phase Power Quality Analyzer (BC# 29550-L/T*)
  • (4) AEMC MN93 Current Clamps
  • (5) AEMC Flexible Test Leads
  • (4) Alligator Clips
  • AC Adapter/Charger
  • (2) Power Cords
  • USB PC Interface Cable
  • Hard Copy User Manual
  • Case For Unit
  • Carrying Case w/ Strap
Request a Quote for

Have Questions or doubts? Submit the following request and expect our detailed quote within 24 hours!

we are commited to win your business!