Agilent E6000C E6012A kit with accessories

Agilent HP E6000C OTDR w/ E6012A SM Fiber Module

Agilent E6012A module with fiber cables

Agilent HP E6012A SingleMode OTDR Module

Agilent HP E6000C SM MM Fiber OTDR w E6012A E6005A

$0.00
Availability: Out of stock
SKU
4B13

Condition: Refurbished / Calibrated

Warranty: 90 Day Exchange

Request a Quote for

Have Questions or doubts? Submit the following request and expect our detailed quote within 24 hours!

we are commited to win your business!

The Agilent Mini-OTDR is the best selling product in Agilent's portfolio of Optical Network Test Solutions for the installation, maintenance and operation of fiber networks.

The Mini-OTDR is designed to provide its users with the fastest tool available for installing and commissioning multiple fiber links and locating faults for fiber maintenance. This is accomplished through high measurement performance and an award winning simple user interface.

Fiber Break Locator to quickly find breaks and bends.

Locate and characterize splice and connector losses.

Multifiber testing for fast high-count cable qualification.

Perform power and loss measurement with the built-in light source and the power meter module.

Graphical representation of measurement results in event tables, showing loss and reflection, and pass/fail results.

Visual Fault Finder to check patch cords for light leakage.

Characteristics:

Horizontal Parameters

  • Start-km:
  • 0 km to 400 km Span: 0.1 km to 400 km
  • Readout resolution: 0.1 m
  • Minimum sample spacing: 4 cm
  • Refractive index: 1.00000 to 2.00000
  • Length unit: km, ft, or miles
  • Measurement points: up to 64000


Vertical Parameters

  • Vertical scale
  • 0.1 to 10.0 dB/Div Read-out resolution: 0.001 dB
  • Reflectance range: 14 dB to 60 dB
  • Backscatter coefficient: 10 to 70 dB at 1 s



Pulsewidth

  • You can select any of the following pulsewidths: 10 ns, 30 ns, 100 ns, 300 ns, 1 s, 3 s, and 10 s (all modules). You can also select 5 ns for E6003C, 5A, 9A modules, and 20 s for E6003B, E6003C, E6008B, and E6013A.
  • With the E6005A module, you can select a pulsewidth from 5 ns to 100 ns at 850 nm, and from 5 ns to 10 s at 1300 nm.
  • With the E6009A module, you can select a pulsewidth from 5 ns to 100 ns at 850 nm, and from 5 ns to 1 s at 1300 nm.



Storage

  • 3.5 floppy disk drive: for high density 720/1440 kByte floppy disks. MS-DOS format compatible. Reduced operating temperature of 5C to 45C, with 35% to 80% humidity at 40C. Memory Card: PCMCIA Type II. 440 MB with up to 13000 traces (typical with 64000 data points).
  • Internal memory: SRAM up to 2 MB. Up to 300 traces (typical) with 4000 data points



OTDR Trace Formats:

  • Trace format: compliant to the following Bellcore/Telcordia OTDR trace formats:
    • GR 196, Revision 1.0
    • GR 196, Revision 1.1
    • SR-4731 Revision 2.0
  • Trace Information: 5 comment labels of up to 15 alphanumeric characters, and 5 comment fields of up to 41 alphanumeric characters are provided for each trace.
  • Real-time clock and date



Scan Trace:

Type of events:

  • Reflective and nonreflective. Maximum number of events: 100.
  • Threshold for non-reflective events: 0.0 to 5.0 dB, selectable in 0.01 dB steps.
  • Threshold for reflective events: - 14.0 to ?65.0 dB, selectable in 0.1 dB steps.
  • Threshold for fiber breaks: 0.1 to 10 dB, selectable in 0.1 dB steps.
  • Fiber End Threshold: 0.1 to 20 dB, selectable in 0.1 dB steps.
  • Display Color or monochrome VGA-LCD: 18.3 cm (7.2?)
  • Display points: 640 x 480 Points
  • Measurement update rate: two measurements per second in refresh mode



Interfaces:

  • RS232C: Maximum transmission rate: 115200 bps Transmission time at 115200 bps for trace data: 4000 points at approx. 1 second; 64000 points at approx. 4 seconds.
  • Centronics: Standard parallel port (SPP).
  • Keyboard: PS2 (Min-DIN). For English Standard, PS2, or AT keyboard.



General:

  • Automatic setup analysis
  • Instrument settings: storage and recall of user-selectable instrument settings.
  • Laser safety class: All OTDR laser sources specified by this data sheet are classified as Class 1M according to IEC 60825-1 (2001).
  • The Visual Fault Finder Sub-Module E6007A complies with Class 2 according to IEC 60825-1 (2001).
  • All laser sources comply with 21 CFR 1040.10 except for deviations pursuant to Laser Notice No. 50, dated 2001-July-26


Built-in Applications:

  • Automatic Multi Fiber Test
  • Pass/Fail Test
  • Fiber Break Locator
  • Power Meter / Loss Test mode 1
  • Visual Fault Finder mode 1
  • Optical Return Loss
  • End to End Loss
  • Easy OTDR
  • OTDR Training
  • OTDR Assistant



Environmental

  • Operating Temperature: 0 to 50 degees C Storage Temperature: 40 to +60 degrees C
  • Humidity: 95% R.H from 0 to 40 degrees C



Power

  • AC: 100 240 Vrms
  • 10% 50 60 Hz DC: 16 24 V
  • External Battery: NiMHtypically 8 hours continuous operation (minimum 4 hours) with Option #006. Charging time < 3 hours, non-operating
  • Low battery indicator
  • Battery charge status

E6000C Specifications

Central Wavelength 1550 nm ± 25 nm/1625 nm ± 20 nm
Applicable Fiber single-mode
Pulsewidth 10 ns 100 ns 1 µs 10 µs 20 µs
Dynamic Range [dB] 22/18 27/24 34/30 41/40 43/ -
Event Deadzone 3 m
Attenuation Deadzone 12/14 m

E6005A Specifications

Central Wavelength 850 nm ± 30 nm/1300 nm ± 30 nm
Applicable Fiber multimode 62.5 µm
Pulsewidth 10 ns 100 ns 1 µs 10 µs
Dynamic Range [dB] 19/17 26/22 - /28 - /34
Event Deadzone 3 m
Attenuation Deadzone 12/14 m




For full Agilent E6000C E6012A E6005A product specifications, please click here: Agilent E6000C E6012A E6005A
Agilent HP E6000C Mini-OTDR With E6012A Singlemode 1550nm & 1625nm And E6005A Multimode 850nm & 1300nm Modules

Dynamic Range
850/1300nm : 26/22dB
1550/1625nm : 41/40dB

Complete With Accessories As Listed & Carrying Case!

Agilent E6000C E6012A E6005A E-6000C E-6012A E-6005A OTDR Models On Sale Warranty Calibration Backed by The Best Service and Lowest Prices in the Industry.
  • Agilent E6000C OTDR Mainfame
    • Option: 003 Color Screen
  • Agilent E6012A SinlgeMode Module
    • 1550nm
    • 1625nm
    • Option: 000
  • Agilent E6005A MM Module
    • 850nm
    • 1300nm
    • Option: 000
  • Fiber Cables:
    • (2) SM SC-SC
    • (2)?MM ST-ST
  • Fiber Connectors:
    • SC-SC
    • ST-ST?
  • Agilent E6091A OTDR ToolKit II Plus
  • Battery Pack
  • AC Adapter/Charger
  • Power Cord
  • RS232 PC Interface Cable
  • Keyboard
  • Agilent OTDR & Fiber Breaker Locator Support CD-ROM
  • User Manual On CD-ROM
  • Carrying Strap
  • Hard Carrying Case