Alber Cellcorder CRT-300
Liebert offers the latest in battery monitoring technology with products by Albér ラ a leader in the field since 1972. Albér technologies by Liebert are designed to prevent battery failure, optimize useful battery life, reduce maintenance cost and increase safety.

The Albér Cellcorder CRT-300 Cell Resistance Tester
The Albér Cellcorder CRT-300 cell resistance tester displays and records cell float voltage, internal cell resistance and intercell connection resistance.
The portable unit is lightweight, rugged and durable. Standard features include a memory card, backlit graphical reflective LCD display for better contrast and specially designed cables and  clamps with interchangeable jaws  for different battery post designs.  A built-in infrared port provides wireless communications to printer, PDA, DMA-35N Hydrometer or laptop computer.

Accurate Data in a Fraction of Normal Test Time
The Albér Cellcorder can be used on single cell or multicell modules. The memory card allows a virtually unlimited amount of data storage. The memory card, infrared port or optional internal modem transfers readings to a PC for analysis and report generation. Using a compatible hydrometer, you may also download specific gravity and temperature data to the Cellcorder using the wireless infrared port. The high contrast, 128 x 64 pixel, backlit graphical display shows menus and test results. A fully charged Cellcorder can test for seven hours while isolated operation helps ensure safety and makes the unit easy to move around.

System Capabilities:

  • Float Voltage Readings
    • The Cellcorder measures the voltage applied during full float operation. The voltage range covers all cells or modules up to 20 volts with accuracy up to four full digits.
  • Internal Cell Resistance
    • Using a patented process, the Cellcorder applies a momentary load and calculates internal cell resistance by determining instantaneous voltage drop and load current. Algorithms make this measurement possible on cells floating on-line or off-line.
  • Intercell Resistance
    • The Cellcorder measures the resistance between two electrically connected cell terminals. The measurement consists of connector resistance and contact resistance at the points of connection to the cell terminals.
  • Auto Ranging
    • The Cellcorder automatically selects the correct voltage range, load resistor, and time for a test.
  • Reliable Readings
    • The Cellcorder performs even in high noise environments - without the need to disconnect the battery from service. Up to a 60 amp DC load (on 2V cells)  is used to calculate internal cell resistance and intercell resistance. Circuitry rejects the 50Hz/60Hz ripple often troublesome to AC-based impedance and conductance meters.
  • Easy-To-Use
    • Includes a combination keypad for alphanumeric data entry plus shift key for quick function keys. Interactive, multi-function menu buttons correlate to relevant menu selections on screen. A navigation  key allows easy selection of choices  in menu.


Specifications:

 
Physical
Dimensions H 12ヤ (305mm) x W 7ヤ (178mm) x D 3ヤ (76mm)
Weight 3.4lb (1.5Kg)
Keypad  Rubber keys with polyurethane coating
Display
Type LCD - STN Reflective
Viewing Area  2.619ヤ x 1.309ヤ
Resolution Graphics LCD 128 x 64
Viewing Angle 40ヤ
Backlight  White EL
Memory
Type  Smart Media Card
Supported Sizes 8MB, 16MB, 32MB, 64MB and 128MB (8MB supplied)
Storage Capacity 71 strings with 256 cells per megabyte (8MB size card can store 568 strings)
Data Retention 10 years
Communication
Infrared Fully lrDA compliant for PDA/PC Interface. Physical IrDA compliant for printer interface.
Battery
Type 4 cell - 8800 mAh Lithium ion
Voltage 4.2V
Charge Time  8 hrs.
AC Adapter
Input Voltage 90-264 VAC
Output Voltage 5 VDC
Output Current 4.0 Amps
Frequency 47-63 Hz
Environmental
Temperature Range:
Operating

0°C to 40°C (32°F to 104°F)
Storage -20°C to 60°C (-20°F to 140°F)
Humidity Range 0% to 80% RH (non-condensing) at 0°C to 31°C;
0% to 50% RH (non-condensing) at 32°C to 40°C
Insulation Category II
Pollution Degree 2
Altitude  0 to 2000 meters above sea leve




For full Alber CRT-300 product specifications, please click here: Alber CRT-300

Alber Cellcorder CRT-300 Cell Resistance Tester

The Albér Cellcorder CRT-300 cell resistance tester displays and records cell float voltage, internal cell resistance and intercell connection resistance

Includes Carrying Case & Accessories As Listed

CRT300 CRT 300

Alber CRT-300 CRT 300 CellCorder Models On Sale Warranty Calibration Backed by The Best Service and Lowest Prices in the Industry.

 

BC# 43025-L/T*

 

  • Alber Cellcorder CRT-300 Cell Resistance Tester (BC# 43025-L/T*)
  • Alber 1100-221 Test Lead Clamp Set
  • Alber Voltage Lead Assembly
  • AC Adapter/Charger
  • Power Cord
  • Strap For Unit
  • User Manual On CD-ROM
  • Hard Carrying Case