Anritsu MT8212A Cell Master - Base Station Test Tool

The Anritsu MT8212A is an all-in-one, rugged, handheld analyzer for the everyday technician to maintain and troubleshoot wireless base station systems. A single, lightweight, handheld, battery-operated package, the Anritsu Cell Master combines the functionality of a cable and antenna analyzer, spectrum analyzer, power meter, T1 and E1 analyzer.

This optimal combination of network test capability eases the job of a network technician by eliminating the need for several independent test instruments, and reducing the number of tools the technician must carry and learn to operate. The Anritsu MT8212A Cell Master is an easy-to-use and rugged solution that has been designed specifically for field-based network technicians and engineers

Cell Master MT8212A is a comprehensive, one-box base station test tool for deploying, maintaining and troubleshooting wireless base stations. Combining the functionality of a cable and antenna analyzer (25 MHz to 4000 MHz), spectrum analyzer (10 MHz to 3.0 GHz), power meter, and T1/E1 analyzer into one lightweight, handheld test set - eliminates the need for field engineer and field technician to carry, manage and learn multiple test sets. MT8212A measurement capability includes precision return loss, VSWR, cable loss, distance-to-fault, signal identification, interference analysis, channel power, adjacent channel power ratio, field strength, transmitter power and T1/E1 measurements. Patented RF interference rejection enables accurate, repeatable measurements in the presence of high RF activity. PC data analysis software enables assessment of system trends, problems, and performance in addition to professional report generation.

The MT8212A includes PC data analysis software, soft carrying case, rechargeable battery, AC/DC power supply, 12 V automotive cigarette lighter adapter, RS232 null modem serial cable and userメs guide.

Features

  • Handheld, battery-operated, under 5 lbs (2.28 kg), including battery
  • Rechargeable, snap-in field replaceable battery
  • Withstands repeated drops and rough handling
  • Weather resistant seals and rubber membrane keypad protect unit from dirt and moisture
  • Built-in worldwide signal standards and frequency channels
  • Multilingual user interface: English, French, Chinese, Japanese, Spanish, German
  • Intuitive and easy to use with on-screen test set-ups and single key functions
  • No external power sensor required for power meter measurements
  • Store/Recall 25 (Cable and Antenna analyzer - 10), (Spectrum Analyzer - 5), (Power Meter - 5), and (T1/E1 Analyzer - 5) setup configurations. Up to 200 traces
  • Alphanumeric labeling and automatic time/date stamp of saved measurements
  • 6 markers, limit line, and segmented limit lines
  • Trace overlay, trace math
  • Superior immunity to RF interference
  • 130, 259 and 517 data points for optimal resolution and long range fault locations
  • FlexCalル allows troubleshooting cable and antenna systems without multiple calibrations and calibration setups
  •  < 3.5 msec per datapoint to identify real time intermittent cable problems
  • ± 0.5 dB typical amplitude accuracy power measurements
  • -135 dBm typical DANL
  • Interference analysis
  • T1 and E1 histograms

Handheld PC Software Analysis Tools Features

  • Transfer traces with a single menu selection
  • Stores an unlimited number of data traces for comparison to historical performances
  • Trace overlay for on-screen comparison of current measurements to previously saved measurements
  • On screen モclick and dragヤ, zoom and change measurement units capabilities
  • Graphical or tabular clipboard format and export format
  • Cable editor supports downloading and uploading cable list and saving as a file
  • Antenna editor supports downloading and uploading cable list and saving as a file
  • Distance-to-fault and Smith Chart analysis

Easy-to-Use

  • Menu driven interface and single keystroke functions reduce training for all measurements
  • Store/Recall 25 setup configurations and up to 200 traces
  • Built-in intelligence to ensure calibration is performed correctly
  • FlexCalル allows troubleshooting cable and antenna systems without multiple calibrations and calibration setups
  • Built-in worldwide signal standards and frequency channels
  • No external power sensor required for power meter measurements
  • Multilingual user interface features on-screen menus and messages in 6 different languages

Accurate, Repeatable Measurements

  • Utilizes vector error correction in cable and antenna measurements
  • 130, 259 and 517 data points for optimal resolution and fault locations
  • Superior immunity to interference
  • < 500 msec per sweep to measurement speeds identify real time intermittent cable problems
  • ±0.5 dB typical amplitude accuracy power measurements
  • -135 dBm typical DANL

Portability

  • Handheld and light weight under 5 lbs (2.28 kg) including battery make it ideal to carry and to use in confined spaces
  • Field replaceable snap-in battery doubles test performance time

Rugged and Reliable

  • Operates in extreme cold and hot environments (-10°C to +50°C /14°F to 122°F)
  • Weather resistant seals and rubber membrane keypad protects unit from dirt and moisture
  • Withstands repeated drops and rough handling

Specifications

Cable and Antenna Analyzer

Frequency Range 25 MHz to 4.0 GHz
Accuracy =± 75 ppm @ +25°C
Resolution 100 kHz
Output Power < 0 dBm (ヨ10 dBm nominal)
Immunity to Interfering Signals on-channel +17 dBm
on-frequency ヨ5 dBm
Measurement speed .3.5 msec / data point (CW ON)
Number of data points 130, 259, 517
Return Loss Range 0.00 to 60.00 dB
Resolution 0.01 dB
VSWR Range 1.00 to 65.00
Resolution 0.01
Cable Loss Range 0.00 to 30.00 dB
Resolution 0.01 dB
Measurement Accuracy > 42 dB corrected directivity after calibration
Distance-To-Fault Vertical Range Return Loss: 0.00 to 60.00 dB
VSWR: 1.00 to 65.00
Horizontal Range Range: 0 to (# of data pts ヨ1) x Resolution to a maximum of 1197m (3929 ft),
# of data pts = 130, 259, 517
Horizontal Resolution
(Rectangular windowing)
Resolution (meter) = (1.5 x 10^8) x (Vp)/DF
Where Vp is the cable's relative propagation velocity and where DF is the stop
frequency minus the start frequency (in Hz)

Spectrum Analyzer

F
r
e
q
u
e
n
c
y
Range  10 MHz to 3.0 GHz 
Reference (Internal Timebase)  Aging: ± 1 ppm/yr
Accuracy: ± 2 ppm
Span  10 Hz to 2.99 GHz in 1, 2, 5 step selections in auto mode, plus zero span
Sweep Time  =1.1 sec full span; =50 µsec to 20 sec zero span
Resolution Bandwidth (.3 dB)  100 Hz to 1 MHz in 1-3 sequence ± 5% Accuracy
Video Bandwidth (.3 dB)  3 Hz to 1 MHz in 1-3 sequence ± 5% Accuracy
SSB Phase Noise (1 GHz) @ 30 kHz Offset  =ヨ75 dBc/Hz
Spurious Responses  =ヨ45 dBc
Spurious Residual Responses  =ヨ90dBm, (10 kHz RBW, pre-amp on)
A
m
p
l
i
t
u
d
e
Total Level Accuracy  ±1 dB max (± 0.5 dB typical) for input signal levels =ヨ60 dBm (10 MHz to 2 GHz, excludes input
VSWR mismatch)
Measurement Range  +20 dBm to ヨ135 dBm
Input Attenuator Range  0 to 51 dB, selected manually or automatically coupled to the reference level. Resolution in 1 dB steps.
Displayed Average Noise Level  =ヨ135 dBm typical (Input terminated, 0 dB attenuation, RMS detection, 100 Hz RBW, preamp on)
Dynamic Range  >65 dB
Display Range  1 to 15 dB/division, in 1 dB steps, 10 divisions displayed
Scale Units  dBm, dBV, dBmV, dBµV
RF Input VSWR  (=20 dB atten.) 1.5:1 typical, (10 MHz to 2.4 GHz)

Power Meter

Frequency Range 10 MHz to 3.0 GHz
Display Range ヨ80 dBm to +80 dBm
Offset Range 0 to +60 dB
Accuracy ±1 dB max (± 0.5 dB typical) for input signal levels =ヨ60 dBm, 10 MHz to 2 GHz excludes input VSWR
VSWR 1.5:1 typical (Pin > ヨ30 dBm, 10 MHz to 2.4 GHz)
Maximum Power 20 dBm (0.1W) without external attenuator

T1 Analyzer

Line Coding AMI, B8ZS
Framing Modes D4 (Superframe), ESF (Extended Superframe)
Connection Configurations Terminate (100 O)
Bridge (=1000 O)
Monitor (Connect via 20 dB pad in DSX)
Receiver Sensitivity 0 to ヨ36 dBdsx
Transmit Level 0 dB, ヨ7.5 dB, and ヨ15 dB
Clock Sources External
Internal: 1.544 MHz ± 30 ppm
Pulse Shapes Conform to ANSI T1.403
Pattern Generation
and Detection
PRBS: 2-9, 2-11, 2-15, 2-20, 2-23 Inverted and
non-inverted, QRSS, 1-in-8 (1-in-7), 2-in-8, 3-in-
24, All ones, All zeros, T1-Daly, User defined
(=32 bits)
Circuit Status Reports Carrier present, Frame ID and Sync., Pattern ID and Sync.
Alarm Detection AIS (Blue Alarm), RAI (Yellow Alarm)
Error Detection Frame Bits, Bit, BER, BPV, CRC, Error Sec
Error Insertion Bit, BPV, Framing Bits, RAI, AIS
Loopback Modes Self loop, CSU, NIU, User defined, In-band or
Data Link
Level Measurements Vp-p (± 5%)
Data Log Continuous, up to 48 hrs

E1 Analyzer

Line Coding AMI, HDB3
Framing Modes PCM30, PCM30CRC, PCM31, PCM31CRC
Connection Configurations Terminate (75, 120 O)
Bridge (=1000 O)
Monitor (Connect via 20 dB pad in DSX)
Receiver Sensitivity 0 to ヨ43 dB
Clock Sources External
Internal 2.048 MHz ± 30 ppm
Pulse Shapes Conform to ITU G.703
Pattern Generation and Detection PRBS: 2-9, 2-11, 2-15, 2-20, 2-23 Inverted and
non-inverted, QRSS, 1-in-8 (1-in-7), 2-in-8, 3-in-
24, All ones, All zeros, T1-Daly, User defined
(32 bits)
Circuit Status Reports Carrier present, Frame ID and Sync., Pattern ID
and Sync.
Alarm Detection AIS, RAI, MMF
Error Detection Frame Bits, Bit, BER, BPV, CRC, E-Bits, Error
Sec
Error Insertion Bit, BPV, Framing Bits, RAI, AIS
Loopback Modes Self loopback
Level Measurements Vp-p (± 5%)
Data Log Continuous, up to 48 hrs



For full Anritsu MT8212A product specifications, please click here: Anritsu MT8212A

Anritsu CellMaster MT8212A Cable, Antenna and Base Station Analyzer

Combines the functionality of a Cable & Antenna Analyzer (25 MHz to 4 GHz), Spectrum Analyzer (10 MHz to 3.0 GHz), Power Meter, and T1/E1 Analyzer into one lightweight, handheld test set!

Includes Hard Carrying Case & Accessories As Listed

Anritsu MT8212A Cell Master Analyzer MT-8212A Cell Master Analyzer Models On Sale Warranty Calibration Backed by The Best Service and Lowest Prices in the Industry.

BC# 18681

  • Anritsu CellMaster MT8212A Cable, Antenna and Base Station Analyzer (BC# 18681)
  • (2) Armored Test Port Cables
  • (4) Antennas
  • BNC To BNC Cable
  • Meca Attenuator P/N: 612-20-1
  • Meca Attenuator P/N: 612-10-1
  • Meca Atteunator P/N: 612-10-1R
  • (2) Meca Attenuators P/N: 612-03-1
  • MicroLab Attenuator P/N: AM-10N
  • 7/16 DIN Male To DIN Male Barrel Adapter
  • BNC To BNC Adapter
  • 7/16 DIN Male To N Female Adapter
  • 7/16 DIN Female To N Female Adapter
  • 7/16 N Female To DIN Male Right Angle Adapter
  • (2) 7/16 DIN Male To N Female Adapters
  • 7/16 DIN Male To N Female Adapter P/N: 2N-10dB
  • DC Car Charger
  • AC Adapter/Charger
  • Power Cord
  • RS232 PC Interface Cable
  • Hard Copy User Manual
  • Hard Carrying Case